IBM Support

ServeRAID M5014 SAS/SATA controller fails to rebuild RAID-5 array - IBM System x

Troubleshooting


Problem

ServeRAID M5014 SAS/SATA Controller, Option part number 46M0916, intermittently fails in rebuilding a Redundant Array of Independent Disks 5 (RAID 5) array. The IBM Dynamic System Analysis (DSA) IMPI log will show the following output: | IPMI:(03/28/2012 13:06:35) Disk or disk bay 1 (Drive Slot (Bay) - Drive 1): Assertion: Drive Fault | IPMI:(03/28/2012 13:04:29) Disk or disk bay 1 (Drive Slot (Bay) - Drive 1): Assertion: Rebuild/Remap in progress | IPMI:(03/28/2012 13:03:07) Disk or disk bay 1 (DriveSlot (Bay) - Drive 1): Deassertion: Drive Presence | IPMI:(03/28/2012 12:44:28) Disk or disk bay 0 (Drive Slot (Bay) - Drive 0): Assertion: In Critical Array | IPMI:(03/28/2012 12:44:28) Disk or disk bay 2 (Drive Slot (Bay) - Drive 2): Assertion: In Critical Array | IPMI:(03/28/2012 12:44:28) Disk or disk bay 4 (Drive Slot (Bay) - Drive 4): Assertion: In Critical Array

Resolving The Problem

Source

RETAIN tip: H205825

Symptom

ServeRAID M5014 SAS/SATA Controller, Option 46M0916, intermittently fails in rebuilding a Redundant Array of Independent Disks 5 (RAID 5) array.

The IBM Dynamic System Analysis (DSA) IMPI log will show the following output:

  | IPMI:(03/28/2012 13:06:35) Disk or disk bay 1 (Drive Slot (Bay) - Drive 1): Assertion: Drive Fault
| IPMI:(03/28/2012 13:04:29) Disk or disk bay 1 (Drive Slot (Bay) - Drive 1): Assertion: Rebuild/Remap in progress
| IPMI:(03/28/2012 13:03:07) Disk or disk bay 1 (Drive Slot (Bay) - Drive 1): Deassertion: Drive Presence
| IPMI:(03/28/2012 12:44:28) Disk or disk bay 0 (Drive Slot (Bay) - Drive 0): Assertion: In Critical Array
| IPMI:(03/28/2012 12:44:28) Disk or disk bay 2 (Drive Slot (Bay) - Drive 2): Assertion: In Critical Array
| IPMI:(03/28/2012 12:44:28) Disk or disk bay 4 (Drive Slot (Bay) - Drive 4): Assertion: In Critical Array
| IPMI:(03/28/2012 12:44:26) Disk or disk bay 5 (Drive Slot (Bay) - Drive 5): Assertion: In Critical Array
| IPMI:(03/28/2012 12:44:26) Disk or disk bay 1 (Drive Slot (Bay) - Drive 1): Assertion: Drive Fault
| IPMI:(03/28/2012 12:44:26) Disk or disk bay 3 (Drive Slot (Bay) - Drive 3): Assertion: In Critical Array

Affected configurations

The system may be any of the following IBM servers:

  • System x3200 M3, type 7327, any model
  • System x3200 M3, type 7328, any model
  • System x3250 M3, type 4251, any model
  • System x3250 M3, type 4252, any model
  • System x3250 M3, type 4261, any model
  • System x3400 M2, type 7836, any model
  • System x3400 M2, type 7837, any model
  • System x3400 M3, type 7378, any model
  • System x3400 M3, type 7379, any model
  • System x3500 M2, type 7839, any model
  • System x3500 M3, type 7380, any model
  • System x3550 M2, type 4198, any model
  • System x3550 M2, type 7946, any model
  • System x3550 M3, type 4254, any model
  • System x3550 M3, type 7944, any model
  • System x3620 M3, type 7376, any model
  • System x3630 M3, type 7377, any model
  • System x3650 M2, type 4199, any model
  • System x3650 M2, type 7947, any model
  • System x3650 M3, type 4255, any model
  • System x3650 M3, type 7945, any model
  • System x3690 X5, type 7147, any model
  • System x3690 X5, type 7148, any model
  • System x3690 X5, type 7149, any model
  • System x3690 X5, type 7192, any model
  • System x3755 M3, type 7164, any model
  • System x3850 X5, type 7143, any model
  • System x3850 X5, type 7145, any model
  • System x3850 X5, type 7146, any model
  • System x3850 X5, type 7191, any model

The system is configured with one or more of the following IBM Options:

  • ServeRAID M5014 SAS/SATA Controller, Option part number 46M0916, replacement part number (CRU) 46M0918

This tip is not software specific.

The prior 12.12.0-0047 firmware for the ServeRaid M5014 is affected.

Solution

This issue is fixed beginning in ServeRAID M5014 SAS/SATA controller firmware version 12.12.0-0047 - 12.12.0-0098.

The file is available at the following URL:

Additional information

The root cause of this symptom is due to ACK/NAK timeouts while the ServeRAID M5014 SAS/SATA controller is rebuilding a RAID 5 array.

ServeRAID M5014 SAS/SATA controller firmware version 12.12.0-0047 and later fix the symptoms by improving the recovering mechanism.

When the symptoms occur, it is safe to update ServeRAID M5014 SAS/SATA controller firmware while the RAID 5 array in critical state.

Document Location

Worldwide

Operating System

System x:Operating system independent / None

System x Hardware Options:Operating system independent / None

[{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HWX10","label":"System x->System x3400 M2"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HWX20","label":"System x->System x3500 M2"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HWX30","label":"System x->System x3550 M2"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HWX40","label":"System x->System x3650 M2"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HWX50","label":"System x->System x3200 M3"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HWX60","label":"System x->System x3250 M3"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HWX70","label":"System x->System x3400 M3"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HWX80","label":"System x->System x3500 M3"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HWX90","label":"System x->System x3550 M3"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HWXA0","label":"System x->System x3650 M3"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HWXB0","label":"System x->System x3690 X5"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HWXC0","label":"System x->System x3850 X5"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HWXG0","label":"System x->System x3620 M3"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HWXH0","label":"System x->System x3630 M3"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HWXJ0","label":"System x->System x3755 M3"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
30 January 2019

UID