Problem

When importing a RequisitePro® document a runtime error appears causing the import to fail.

Symptom

The full error message is as follows:

Runtime error: Automation error                    
Call was rejected by callee.                      
(RqWordServices.WordWrapper,656,-2147418111)

Cause

This issue is often the result of the Word normal.dot becoming corrupt.

Resolving The Problem

To resolve this issue, perform the following to recreate the normal.dot:

  1. Close RequisitePro, and Microsoft Word.
  2. Search the system for all instances of the normal.dot
  3. Delete all copies of normal.dot.
  4. Open Microsoft Word and save a new document as a test.
  5. Once the test document has been created, a new copy of the normal.dot will be created.
  6. Try to import the document again.

[{"Product":{"code":"SSSHCT","label":"Rational RequisitePro"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Component":"Wizards: Import","Platform":[{"code":"PF033","label":"Windows"}],"Version":"2003.06.13;2003.06.14;2003.06.15;2003.06.16;7.0;7.0.0.1;7.0.0.2;7.0.0.3;7.0.1;7.0.1.1;7.0.1.2","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]