Question

Replacing a Disk in an SSA RAID5 Array

Answer

Replacing a disk in an SSA RAID5 Array


Environment

OS level: 4.3.x - 5.x
SSA Raid 5 Array

Problem

How do I replace a disk in an SSA RAID5 array?

Solution

If the disk has not been rejected from the array:
Enter smitty ssaraid and select the following:
--> Change Member Disks in an SSA RAID Array
--> Remove a disk from an SSA RAID Array
--> Select the array in question and remove pdisk#...

The following steps apply to both rejected and non-rejected disks:
2) Have the CE physically replace the disk (he should set it in service mode).
3) rmdev -dl pdisk# ; cfgmgr -vl ssar
4)Enter smitty ssaraid and select the following:
--> Change/Show use of an ssa physical disk
--> Change the new pdisk's "current use" to Array Candidate.
5) smitty ssaraid
--> Change Member Disks in an SSA RAID Array
--> Add a disk to an SSA RAID Array
--> Add the new pdisk definition to the array

This definition should now be in a "degraded" state. After adding the new disk the array will go into a "Rebuilding" state, and ultimately a "Good" state after the rebuild operation is complete. This progress can be monitored via:

smitty ssaraid
--> List Status of all Defined SSA RAID Arrays
--> These numbers will get smaller as the array rebuilds and once they all go to zero, the array should be in a "Good" State"

This menu does not update dynamically, you will have to exit out, then go back in to see the progress.

[{"Product":{"code":"SWG10","label":"AIX"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Component":"Attached devices","Platform":[{"code":"PF002","label":"AIX"}],"Version":"5.3;5.2;5.1;4.3","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Product":{"code":"SWG10","label":"AIX"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Component":"High availability- cluster- parallel processing","Platform":[{"code":"","label":""}],"Version":"","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}}]