IBM Support

Receiving Message CPFBC10 followed by OPT1797 when loading Virtual Optical Library image catalog into a virtual optical device.

Troubleshooting


Problem

This document provides a circumvention for messages CPFBC10 and OPT1797 when using a virtual optical device with a virtual optical library.

Resolving The Problem

This document provides a circumvention for messages CPFBC10 and OPT1797 when using a virtual optical device.

Attempting to vary on or use a virtual optical device is receiving the following messages:

CPFBC10 - Image catalog &1 not loaded to device &2 followed by:
OPT1797 - System is not enabled for this function

These errors are caused by a problem with the Product Access Code. The product access code is carried with the device, not just with the product. In order for the virtual optical library to know the new product access code, any one of the drives within the optical library must be varied off and then varied back on. The product access code is then loaded into the drive. A new product access key must be acquired from Lab services if the IBM i system serial number changes.

Note: For instructions on restoring the lab services library and adding the product access code, see Section 4.5, Instructions for Installation of the IBM Lab Services Library and License in the Using Image Catalog for Enhanced Optical Library Data Migration and IBM i Environment guide:

http://www-03.ibm.com/systems/resources/systems_i_hardware_storage_optical_imgclgmigrationv2.pdf


There are three commands that can generate the OPT1797 error message without a product access code installed:

1. ADDIMGCLGE DEV(*VOL)
2. ADDIMGCLGE IMGCLG(CATALOG) FROMFILE(*NEW) MEDTYPE(*WORM or *ERASE)
3. LODIMGCLG IMGCLG(CATALOG) DEV(OPTVRTxx) LIBMODE(*YES)

________________

OPT1797 can be generated if the Digital Certificate Manager (DCM) product is not installed on the system.

Note: Once the DCM product is installed, an IPL is required to continue processing.