IBM Support

PureData Systems for Analytics progress of raid rebuild on Host.

Question & Answer


Question

How can I see the rebuild status of the host raid on my N100x, N200x, N300x appliance?

Answer

If a drive has been replaced in a host using the MegaCli64 commands and mega_check.pl is not available, use the commands below to view the rebuild or copyback progress.

View the pdlist to see the slot numbers and the state of the drives:

/opt/MegaRAID/MegaCli is the working directory. All of the commands will require the [Enclosure ID:Slot Number].

[root@NZsystem-H1 MegaCli]# ./MegaCli64 -pdlist -aall | egrep "ID|Slot|state"
Enclosure Device ID: 252
Slot Number: 0
Firmware state: Copyback
Enclosure Device ID: 252
Slot Number: 1
Firmware state: Online, Spun Up
Enclosure Device ID: 252
Slot Number: 2
Firmware state: Online, Spun Up
Enclosure Device ID: 252
Slot Number: 3
Firmware state: Online, Spun Up
Enclosure Device ID: 252
Slot Number: 4
Firmware state: Online, Spun Up
Enclosure Device ID: 252
Slot Number: 5
Firmware state: Online, Spun Up
Enclosure Device ID: 252
Slot Number: 6
Firmware state: Hotspare, Spun Up

The above example shows slot 0 is in copyback. Use the below example to view the progress of the copyback:

[root@NZsystem-H1 MegaCli]# ./MegaCli64 -PDCpyBk -ShowProg -PhysDrv [252:0] -aall

Copyback Progress on Device at Enclosure 252, Slot 0 Completed 91% in 33 Minutes.


If the above drive state is rebuild, issue the following command:

[root@NZsystem-H1 MegaCli]# ./MegaCli64 -pdrbld -progdsply -physdrv [252:0] -aall

Device(Encl-252 Slot-0) is not in rebuild process

Exit Code: 0x00


If it is required to turn on or off the locater on a drive, use the below examples:

[root@NZsystem-H1 MegaCli]# ./MegaCli64 -PdLocate -start -physdrv [252:3] -aall

Adapter: 0: Device at EnclId-252 SlotId-3 -- PD Locate Start Command was successfully sent to Firmware

Exit Code: 0x00


[root@NZsystem-H1 MegaCli]# ./MegaCli64 -PdLocate -stop -physdrv [252:3] -aall

Adapter: 0: Device at EnclId-252 SlotId-3 -- PD Locate Stop Command was successfully sent to Firmware

Exit Code: 0x00

[{"Product":{"code":"SSULQD","label":"IBM PureData System"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Component":"IBM Netezza Analytics","Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.0.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
17 October 2019

UID