IBM Support

SI57491 - RDARS-ONDCSRV-WAIT Allow configurable wait time for STRMONON

PTF Cover Letter


PTF ( Program Temporary Fixes ) Cover letter


Order this fix

Abstract

RDARS-ONDCSRV-WAIT Allow configurable wait time for STRMONON


Pre/Co-Requisite PTF / Fix List

REQ  LICENSED      PTF/FIX  LEVEL

TYPE PROGRAM  REL  NUMBER   MIN/MAX  OPTION
---- -------- ---  -------  -------  ------
PRE  5770RD1  710  SI46535   NONE     0010



NOTICE:
-------
Application of this PTF may disable or render ineffective programs that
use system memory addresses not generated by the IBM translator,
including programs that circumvent control technology designed to limit
interactive capacity to purchased levels.  This PTF may be a prerequisite
for future PTFs.  By applying this PTF you authorize and agree to the
foregoing.

This PTF is subject to the terms of the license agreement which
accompanied, or was contained in, the Program for which you are obtaining
the PTF.  You are not authorized to install or use the PTF except as part
of a Program for which you have a valid Proof of Entitlement.

SUBJECT TO ANY WARRANTIES WHICH CAN NOT BE EXCLUDED OR EXCEPT AS EXPLICITLY
AGREED TO IN THE APPLICABLE LICENSE AGREEMENT OR AN APPLICABLE SUPPORT
AGREEMENT, IBM MAKES NO WARRANTIES OR CONDITIONS EITHER EXPRESS OR IMPLIED,
INCLUDING BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OR CONDITIONS OF
MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON INFRINGEMENT,
REGARDING THE PTF.

The applicable license agreement may have been provided to you in printed
form and/or may be viewed using the Work with Software Agreements (WRKSFWAGR)
CL command.


APAR Error Description / Circumvention

-------------------------------------------------
When the Start Monitor for OnDemand (STRMONOND TYPE(*DIR) or
TYPE(*DIR2)) command finds no more files to process in the
directory being monitored, it waits 90 seconds before checking
the directory again to see if there are new files to process.
For some, this hardcoded delay is too long.

The Create Instance for OnDemand (CRTINSTOND) command puts an
incorrect value in message CPD1441 when the job description
specified in the Job Description (JOBD) parameter cannot be
found.

The Start Monitor for OnDemand (STRMONOND) command does not
allow *CURLIB for the Processed output queue (PRCOUTQ)
parameter.

CORRECTION FOR APAR 'SE61644' :
-------------------------------
A new Check interval (CHKITV) parameter has been added to allow
the wait time to be configurable from 1 to 90 seconds.

The problem is fixed.

The problem is fixed.

CIRCUMVENTION FOR APAR 'SE61644' :
----------------------------------
None.


Activation Instructions


None.




Special Instructions

None.


Default Instructions

THIS PTF CAN BE APPLIED IMMEDIATE OR DELAYED.



Supersedes

PTF/FIX NO(S).  APAR TITLE LINE
--------------  ------------------------------------------------------------
   SI51748      RDARS-ONDCSRV-T/QRLMVCIN-RC2-MSGCPF0804
   SI49235      RDARS-ONDCSRV-UNPRED UPDATE PRTRPTOND TO 9.0.0.1
   SI49235      RDARS-ONDCSRV-INCORROUT-MSGOND0106 RMVRPTOND command fails w
   SI46536      RDARS-ONDCSRV-UNPRED UPDATE PRTRPTOND to 8505 server level
   SI42895      RDARS-ONDCSRV-INCORROUT CRTINSTOND MSGOND0629 NOT HANDLED CO
   SI36375      OSP-INCORROUT Miscellaneous command fixes
   SI54782      RDARS-ONDCSRV-LOOP IF .IND FILE REINTRODUCED TO IFS DIRECTOR
   SI39555      RDARS-ONDCSRV-INCORROUT STRMONOND with APPSRC(*APPGRP) incon
   SI38544      RDARS-ONDCSRV-INCORROUT MSGW on STRMONOND after IPL
   SI35695      RDARS-ONDCSRV-F/QRLMMONQ-T/QRLMMONQ-MSGOND0133 message text

Summary Information

System..............................i
Models..............................
Release.............................V7R1M0
Licensed Program...............5770RD1
APAR Fixed..........................View details for APAR SE61644
Superseded by:......................View fix details for PTF SI66309
Recompile...........................N
Library.............................QRDARS
MRI Feature ........................NONE
Cum Level...........................C5317710


System i Support

IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information.

[{"Type":"MASTER","Line of Business":{"code":"LOB57","label":"Power"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SWG60","label":"IBM i"},"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"7.1.0"},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG15V","label":"PTF Cover Letters - OS\/400 General"},"Component":"","ARM Category":[],"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"V7R1M0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
14 August 2015