IBM Support

SI54782 - RDARS-ONDCSRV-LOOP IF .IND FILE REINTRODUCED TO IFS DIRECTOR

PTF Cover Letter


PTF ( Program Temporary Fixes ) Cover letter


Order this fix

Abstract

RDARS-ONDCSRV-LOOP IF .IND FILE REINTRODUCED TO IFS DIRECTOR


Pre/Co-Requisite PTF / Fix List

REQ  LICENSED      PTF/FIX  LEVEL

TYPE PROGRAM  REL  NUMBER   MIN/MAX  OPTION
---- -------- ---  -------  -------  ------
NONE



NOTICE:
-------
Application of this PTF may disable or render ineffective programs that
use system memory addresses not generated by the IBM translator,
including programs that circumvent control technology designed to limit
interactive capacity to purchased levels.  This PTF may be a prerequisite
for future PTFs.  By applying this PTF you authorize and agree to the
foregoing.

This PTF is subject to the terms of the license agreement which
accompanied, or was contained in, the Program for which you are obtaining
the PTF.  You are not authorized to install or use the PTF except as part
of a Program for which you have a valid Proof of Entitlement.

SUBJECT TO ANY WARRANTIES WHICH CAN NOT BE EXCLUDED OR EXCEPT AS EXPLICITLY
AGREED TO IN THE APPLICABLE LICENSE AGREEMENT OR AN APPLICABLE SUPPORT
AGREEMENT, IBM MAKES NO WARRANTIES OR CONDITIONS EITHER EXPRESS OR IMPLIED,
INCLUDING BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OR CONDITIONS OF
MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON INFRINGEMENT,
REGARDING THE PTF.

The applicable license agreement may have been provided to you in printed
form and/or may be viewed using the Work with Software Agreements (WRKSFWAGR)
CL command.


APAR Error Description / Circumvention

-------------------------------------------------
Customer had a set of .ind and .out files in an IFS directory
that the Content Manager OnDemand directory monitor processed
successfully, appending .PRC to the .ind file name as expected.
Later, the same .ind file was inadvertently placed back into the
monitored IFS directory.

The monitor issued message CPFA0A0 after loading the duplicate
file. The message was issued when the monitor was not able to
append the .PRC extension to the .ind file because it already
existed in the directory from the previous load. The monitor
continued to process the input .ind file repeatedly since it
never successfully renamed the .ind file. The loading continued
until the monitor was ended manually. This resulted in a number
of duplicate files loaded into Content Manager OnDemand.

CORRECTION FOR APAR 'SE60277' :
-------------------------------
If a duplicate file is introduced to a monitored directory, it
will be renamed with a file extension of .DUP (or .DUP1 for a
second duplicate, and so forth) and not processed. A new message
will be sent to both the job log and the QSYSOPR message queue
noting this has occurred so that the user can delete the
duplicate file and take action to stop introducing duplicates,
or rename it with a unique name so that it can be processed
successfully. The monitor will then continue on to the next file
without looping.

CIRCUMVENTION FOR APAR 'SE60277' :
----------------------------------
None.


Activation Instructions


None.




Special Instructions

None.


Default Instructions

THIS PTF CAN BE APPLIED IMMEDIATE OR DELAYED.



Supersedes

PTF/FIX NO(S).  APAR TITLE LINE
--------------  ------------------------------------------------------------
   SI39555      RDARS-ONDCSRV-INCORROUT STRMONOND with APPSRC(*APPGRP) incon
   SI38544      RDARS-ONDCSRV-INCORROUT MSGW on STRMONOND after IPL
   SI35695      RDARS-ONDCSRV-F/QRLMMONQ-T/QRLMMONQ-MSGOND0133 message text

Summary Information

System..............................i
Models..............................
Release.............................V7R1M0
Licensed Program...............5770RD1
APAR Fixed..........................View details for APAR SE60277
Superseded by:......................View fix details for PTF SI66309
Recompile...........................N
Library.............................QRDARS
MRI Feature ........................NONE
Cum Level...........................C5142710


System i Support

IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information.

[{"Type":"MASTER","Line of Business":{"code":"LOB57","label":"Power"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SWG60","label":"IBM i"},"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"7.1.0"},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG15V","label":"PTF Cover Letters - OS\/400 General"},"Component":"","ARM Category":[],"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"V7R1M0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
02 October 2014