IBM Support

SI45080 - HA-UNPRED Support for SVC/V7000 reverse FlashCopy

PTF Cover Letter


PTF ( Program Temporary Fixes ) Cover letter


Order this fix

Abstract

HA-UNPRED Support for SVC/V7000 reverse FlashCopy


Pre/Co-Requisite PTF / Fix List

REQ  LICENSED      PTF/FIX  LEVEL

TYPE PROGRAM  REL  NUMBER   MIN/MAX  OPTION
---- -------- ---  -------  -------  ------
PRE  5770SS1  710  SI44141   00/00    0000
PRE  5770SS1  710  SI42297   00/00    0000
PRE  5770SS1  710  SI44326   00/00    0000
PRE  5770SS1  710  SI40309   00/00    0000



NOTICE:
-------
Application of this PTF may disable or render ineffective programs that
use system memory addresses not generated by the IBM translator,
including programs that circumvent control technology designed to limit
interactive capacity to purchased levels.  This PTF may be a prerequisite
for future PTFs.  By applying this PTF you authorize and agree to the
foregoing.

This PTF is subject to the terms of the license agreement which
accompanied, or was contained in, the Program for which you are obtaining
the PTF.  You are not authorized to install or use the PTF except as part
of a Program for which you have a valid Proof of Entitlement.

SUBJECT TO ANY WARRANTIES WHICH CAN NOT BE EXCLUDED OR EXCEPT AS EXPLICITLY
AGREED TO IN THE APPLICABLE LICENSE AGREEMENT OR AN APPLICABLE SUPPORT
AGREEMENT, IBM MAKES NO WARRANTIES OR CONDITIONS EITHER EXPRESS OR IMPLIED,
INCLUDING BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OR CONDITIONS OF
MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON INFRINGEMENT,
REGARDING THE PTF.

The applicable license agreement may have been provided to you in printed
form and/or may be viewed using the Work with Software Agreements (WRKSFWAGR)
CL command.





APAR Error Description / Circumvention

-----------------------------------------------
Support for SAN Volume Controller (SVC) and Storwize V7000
reverse FlashCopy is added to PowerHA System Mirror for i.

CORRECTION FOR APAR SE49753 :
-----------------------------
Function provided.

CIRCUMVENTION FOR APAR SE49753 :
--------------------------------
None.


Activation Instructions


None.




Special Instructions


********************************************************************
THE FOLLOWING ARE SUPERSEDED SPECIAL INSTRUCTIONS. IF THE SUPERSEDED
PTF HAS ALREADY BEEN APPLIED AND ITS SPECIAL INSTRUCTION FOLLOWED,
IT IS NOT NECESSARY TO FOLLOW THAT SPECIAL INSTRUCTION AGAIN.
********************************************************************

SPECIAL INSTRUCTIONS FOR SUPERSEDED PTF SI44148 :
=================================================

This PTF is an Add Function PTF which must be permanently applied.
Removal of this PTF after step #4 below is not supported.

You must have the most recent PTF group SF99368.

You must install PRPQ 5799-HAS in order to use the functions
provided in this PTF.

Step #1:
In order for this PTF to be fully activated, you must end and restart
the QHASVR job.  You can do this by ending and starting the cluster
node using the commands:

ENDCLUNOD CLUSTER(<cluster-name>) NODE(<node-id>)
STRCLUNOD CLUSTER(<cluster-name>) NODE(<node-id>)

Or, you can end the QHASVR job under QSYSWRK subsystem:

ENDJOB JOB(<job-num>/QHAUSRPRF/QHASVR) OPTION(*IMMED)

where <job-num> is the job number.

Issue the WRKCLU command to restart the QHASVR job.

Step #2:
You must restart the *ADMIN instance of the *HTTP server.  Do this
with the following commands:

ENDTCPSVR  SERVER(*HTTPSVR) INSTANCE(*ADMIN)
STRTCPSVR  SERVER(*HTTPSVR) INSTANCE(*ADMIN)

Step #3:
Users must sign off any active sessions which may be using,
PowerHA and sign back on after the PTF has been applied.

Step #4:
After the PTF has been applied on all of the nodes in the
cluster which have PowerHA installed, you must upgrade
the PowerHA version to 2.1.

If your cluster is currently at PowerHA version 1.0,
you must:

CHGCLUVER  CLUSTER(<cluster-name>) HAVER(*UP1VER)
CLUVER(*SAME)

After your cluster is at PowerHA version 2.0, you must:

CHGCLUVER  CLUSTER(<cluster-name>) HAVER(*UP1MOD)
CLUVER(*SAME)

SPECIAL INSTRUCTIONS FOR SUPERSEDED PTF SI36179 :
=================================================

End Cluster Resource Services on the node using the ENDCLUNOD command,
apply the PTF, signoff/signon, and then restart Cluster Resource
Services using the STRCLUNOD command.


Default Instructions

THIS PTF CAN BE APPLIED IMMEDIATE OR DELAYED.



Supersedes

PTF/FIX NO(S).  APAR TITLE LINE
--------------  ------------------------------------------------------------
   SI44148      HA-NF October 2011 PowerHA New Function
   SI44148      New Function: PowerHA GUI
   SI44148      HA-New Function: Provide CFGGEOMIR command
   SI44148      HA-UNPRED SVC / Storwize V7000 Support
   SI44148      HA-New Function: PowerHA N-2 Version Support
   SI44148      HA-INCORROUT Base enablement for IASP functionality
   SI44148      HA-New Function PowerHA GUI
   SI44148      HA-UNPRED SVC / Storwize V7000 Support
   SI44148      HA-UNPRED SVC / Storwize V7000 Support
   SI44148      HA-UNPRED SVC / Storwize V7000 Support
   SI37239      HA-INCORROUT Enable RTVASPCPYD, RTVASPSSN
   SI43597      HA-MSG4429 Unable to display ASP copy description
   SI43434      HA-INCORROUT XSM Unable to vary on ASP after detach
   SI42888      HA-INCORROUT DSPASPSSN Tracking Space Used is incorrect.
   SI42215      HA-INCORROUT Wrong node name displayed for ASP session
   SI42030      HAS-INCORROUT XSM Flashcopy target not identified
   SI41918      HA-INCORROUT Base Function to Enable Future Extensions
   SI41610      HASM-INCORROUT ENHANCEMENT TO PREVENT LOCK CONDITION.
   SI41277      HA-INCORROUT Fields missing in QYASRTVINF
   SI40497      HA-INCORROUT Base Function to Enable Future Extensions
   SI40180      HA-INCORROUT CHGASPSSN *CHGATTR fails for flash copy
   SI39912      HA-INCORROUT Recovery from LUN level switch fails
   SI39674      HA-MSGCPFBBD3 Error invoking CRG exit programs
   SI39549      HA-INCORROUT Must select async mode when async delivery spec
   SI39236      HA-INCORROUT CHGCRGPRI fails for global mirror
   SI39181      HA-INCORROUT Sync progress not correct for DSPASPSSN
   SI38975      HA-MSGHAE2013 STRASPSSN fails
   SI38609      HA-INCORROUT Flash copy role is not correct
   SI38325      HA-INCORROUT QYASPJNEXT fails on remove node
   SI38321      HA-INCORROUT CHGCRGPRI fails with an active CRG
   SI38147      HA-MSGHAE0045 message text not correct
   SI37995      HA-INCORROUT CHGCRGPRI results in QYASSTESWE failure
   SI37995      HA-MSGCPF9D8D Stream file failed to open
   SI37995      HA-INCORROUT CHGCRGPRI fails
   SI37604      HA-INCORROUT Correct PowerHA replication error checking
   SI36607      HA-INCORROUT Unable to change ASP copy description
   SI36607      HA-INCORROUT QYASPJNEXT fails removing a node from a CRG rec
   SI36607      HA-INCORROUT DSPASPCPYD Fails
   SI36607      HA-MSGCPDBB0E Exit program compare fails
   SI36607      HA-MSGHAE2009 Unable to create a flash copy session
   SI36607      HA-INCORROUT Support for space efficient flash copy
   SI36607      HA-INCORROUT Remove consistency parameters from CHGASPSSN
   SI36416      HA-MSGCPFAF02 Unable to run DSCLI command
   SI39031      HA-RCDSSPN3-MSGCPFAF02 unable to run dscli operations using
   SI36972      HA-INCORROUT CRG site does not become active
   SI36179      correction for problems found during final regression test

Summary Information

System..............................i
Models..............................
Release.............................V7R1M0
Licensed Program...............5770HAS
APAR Fixed..........................View details for APAR SE49753
Superseded by:......................View fix details for PTF SI68260
Recompile...........................N
Library.............................QHASM
MRI Feature ........................NONE
Cum Level...........................C2115710


System i Support

IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017, 2018 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG15V","label":"PTF Cover Letters - OS\/400 General"},"Component":"","ARM Category":[],"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"V7R1M0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG16D","label":"PTF Cover Letters - IBM i 7.1 environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"V7R1M0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
16 November 2011