IBM Support

MF67609 - OSP-MSGRNX0112 FIELD PROCEDURE FAILS WITH RNX0112

PTF Cover Letter


PTF ( Program Temporary Fixes ) Cover letter


Order this fix

Abstract

OSP-MSGRNX0112 FIELD PROCEDURE FAILS WITH RNX0112


Pre/Co-Requisite PTF / Fix List

REQ  LICENSED           PTF/FIX  LEVEL

TYPE PROGRAM  RELEASE   NUMBER   MIN/MAX  OPTION
---- -------- --------- -------  -------  ------
CO   5770999  V7R2M0    MF66297   00/00    0000
CO   5770999  V7R2M0    MF66298   00/00    0000
CO   5770999  V7R2M0    MF66299   00/00    0000



NOTICE:
-------
Application of this PTF may disable or render ineffective programs that
use system memory addresses not generated by the IBM translator,
including programs that circumvent control technology designed to limit
interactive capacity to purchased levels.  This PTF may be a prerequisite
for future PTFs.  By applying this PTF you authorize and agree to the
foregoing.

This PTF is subject to the terms of the 'IBM License Agreement for Machine
Code', the terms of which were provided in a printed document that was
delivered with the machine.

SUBJECT TO ANY WARRANTIES WHICH CAN NOT BE EXCLUDED OR EXCEPT AS EXPLICITLY
AGREED TO IN THE APPLICABLE LICENSE AGREEMENT OR AN APPLICABLE SUPPORT
AGREEMENT, IBM MAKES NO WARRANTIES OR CONDITIONS EITHER EXPRESS OR IMPLIED,
INCLUDING BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OR CONDITIONS OF
MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON INFRINGEMENT,
REGARDING THE PTF.





APAR Error Description / Circumvention

-----------------------------------------------
IBM i, OS v7r2. DB2 Field Procs. Receiving a RNX0112 - Date,
Time or Timestamp value is not valid. This happens when a field
proc is applied to the field.

CORRECTION FOR APAR MA48230 :
-----------------------------
NULL Field Proc Date/Time/Timestamp fields will now return a
formatted output value instead of hex 0's.

The values returned for NULL Field Proc Date/Time/Timestamp
fields will be as follows :

DATE      = '0001-01-01'
TIME      = '00.00.00'
TIMESTAMP = '0001-01-01-00.00.00.000000'

Note that the values above are for example only.  The actual
format depends on the specified Date/Time/Timestamp format.

Also note this PTF will not automatically regenerate existing
cursors.   There will be an upcoming 'cursor regen' PTF that
will bundle multiple cases that require regeneration of existing
cursors.

Until then, the cursor over the file will have to be 'manually
regenerated'.  To do this they can do one of the following :

Save the file, delete the file, and then restore it.  Note that
the delete before the restore is key to getting a new cursor
created.

Drop the Field Proc and then add it again ( via ALTER TABLE ).

CIRCUMVENTION FOR APAR MA48230 :
--------------------------------
None.


Activation Instructions


None.




Special Instructions


None.


Default Instructions

THIS PTF CAN BE APPLIED IMMEDIATE OR DELAYED.



Supersedes

PTF/FIX NO(S).  APAR TITLE LINE
--------------  ------------------------------------------------------------
   MF66296      osp database field procedures and buffer data content for nu
   MF66069      OSP-DB read from physical file with field procedure (fieldpr
   MF64712      OSP-DB-OTHER INSERTING TO A FILE WITH A FIELD PROCEDURE MAY
   MF58384      LIC-DB-MSGCPF504D fieldproc error through CQE
   MF57857      LIC-DB-UNPRED Timestamp precision field proc changes (3)

Summary Information

System..............................i
Models..............................
Release.............................V7R2M0
Licensed Program...............5770999
APAR Fixed..........................View details for APAR MA48230
Superseded by:......................
Recompile...........................N
Library.............................QSYS
MRI Feature ........................NONE
Cum Level...........................C1084720


IBM i Support

IBM disclaims all warranties, whether express or implied, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. By furnishing this document, IBM grants no licenses to any related patents or copyrights. Copyright © 1996,1997,1998, 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013, 2014, 2015, 2016, 2017, 2018, 2019, 2020, 2021 IBM Corporation. Any trademarks and product or brand names referenced in this document are the property of their respective owners. Consult the Terms of use link for trademark information.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"7.2","Product":{"code":"SG15V","label":"PTF Cover Letters - IBM i General"},"Component":"5770999","Edition":""},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Platform":[{"code":"PF012","label":"IBM i"}],"Version":"7.2","Product":{"code":"SG16F","label":"PTF Cover Letters - IBM i 7.2"},"Component":"5770999","Edition":""}]

Document Information

Modified date: