PRT Record Requirements

Proprietary format files must be terminated with a PRT record that meets the following layout requirements:

Field IDField NamePositionsLengthDescription
NoneRecord Code01-0303PRT identifies the PRT Interchange Trailer Record. Required.
PRT-01Number of Records04-1209Number of records in the interchange excluding the PRH/PRT or XPH/XPT records. Optional.
PRT-02Interchange Control Number13-2109Unique interchange identifier assigned by the sender. Required.
Note: This number must match the number in the PRH-08 Interchange Control Number field.
PRT-03Filler22-7958Any characters such as blanks. Optional.
PRT-04Variable Record Separator Character8001The record terminator character marking the end of the variable-length record. Required if the PRH-11 field is V. Optional if the PRH-11 field is F.
Note: This value must match the value in the PRH-14 Variable Record Separator Character field.
"

[{"Business Unit":{"code":"BU055","label":"Cognitive Applications"},"Product":{"code":"SS73G6","label":"Sterling Total Payments for Financial Services"},"Component":"","Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"All Versions","Edition":"","Line of Business":{"code":"","label":""}}]