Processor installation - IBM Netfinity 4500R

Product Documentation


Abstract

This document contains Processor installation and upgrade instructions for IBM Netfinity 4500R

Content

Netfinity 4500R Microprocessors and SMP:

Your server comes with one microprocessor installed on the system board. If you install an additional microprocessor, your server can operate as a symmetric multiprocessing (SMP) server. With SMP, certain operating systems and application programs can distribute the processing load between the microprocessors.

  • The microprocessor that is installed in connector U17 is CPU 1 (processor 1). See "Processor Diagram" Below.
  • If a microprocessor is installed in connector U3, it is CPU 2 (processor 2).
  • If the server has only one microprocessor installed, that microprocessor is installed in connector U17 and is the startup (boot) processor.
  • If more than one microprocessor is installed, the microprocessor with the lower stepping level is the startup processor and the microprocessor with the higher stepping level is the application processor.
  • If both microprocessors have the same stepping level, the microprocessor installed in connector U17 is the startup processor and the microprocessor installed in U3 is the application processor.
  • You can determine the stepping levels of the installed microprocessors using the F1 Configuration/Setup utility program.
  • ATTENTION: To avoid damage and ensure proper server operation when you install a new or an additional microprocessor, use microprocessors that have the same cache size and type, and the same clock speed. Microprocessor internal and external clock frequencies must be identical.
  • Compatible Processor option part numbers

Netfinity 4500R Processor Diagram:

netfinity 4500r processor diagram
ID#
Description:
1
Terminator card
2
Microprocessor 2
Compatible part numbers
3
Voltage Regulator Module (VRM)
4
Microprocessor 1 (in connector U17)
5
VRM connector
6
Microprocessor 2 connector (U3)


How to install an additional microprocessor:

  1. Read the documentation that comes with the microprocessor, and review the safety information in your User's Guide.
  2. Turn off the server and peripheral devices and disconnect all external cables and power cords; then remove the cover.
  3. Remove the air baffle [1] by grasping it at the sides and lifting it from the server:
    netfinity 4500r air baffle
  4. Remove the terminator card from the microprocessor connector. Store the terminator card in a safe place in the static-protective package that your new microprocessor is shipped in; you will need to install it again, if you ever remove the microprocessor. Refer to the "Processor Diagram" at the top of this document.
  5. Touch the static-protective package containing the new microprocessor to any unpainted metal surface on the server; then, remove the microprocessor from the package.
  6. Center the microprocessor over the microprocessor connector and carefully press the microprocessor into the connector. Note: To remove a microprocessor, pull upward on the microprocessor handle.
  7. Install the VRM included in the microprocessor kit: Center the VRM over the VRM connector (make sure that the VRM is oriented and aligned correctly), then press the VRM into the connector. Attention: When installing or replacing a VRM, use only a VRM specified for use with the Netfinity 4500R server. Use of other VRMs might cause your server to overheat. Note: If you remove the microprocessor later, remember to install the terminator card in the appropriate microprocessor connector and to remove the VRM.
  8. If you replaced the microprocessor with a different speed microprocessor, change switches 1-4 on the switch block to the appropriate settings, as shown in the following table.

    Microprocessor speed settings:
    Microprocessor Speed:
    Switch 1:
    Switch 2:
    Switch 3:
    Switch 4:
    800/133 MHz Off On On On

  9. Install the air baffle. Make sure the sides of the air baffle fit inside the brackets on the server.
  10. If you have other options to install or remove, do so now; otherwise, reinstall the server cover.
  11. Save the new configuration settings in the F1 Configuration/Setup Utility upon system startup.
  12. Update the system BIOS to the latest level.
  13. Obtain and install an SMP-capable operating system (optional). Netfinity 4500R operating system installation instructions
  14. Installation is complete.