Troubleshooting
Problem
POST error code diagnostics for the IBM eServer xSeries 205
Resolving The Problem
This document is intended for trained servicers who are familiar with IBM server products. Use this document along with advanced diagnostic tests to troubleshoot problems effectively. Before servicing an IBM product, be sure to review the safety information. Click here to review safety information.
In the following error codes, x can be any number or letter.
| Error code/symptom | FRU/action |
|---|---|
| 062 (Three consecutive boot failures using the default configuration) |
|
| 101, 102, 106 (System and processor error) |
System board |
| 114 (Adapter read-only memory (ROM) error) |
|
| 151 (Real time clock error) |
|
| 161 (Real time clock battery error) |
|
|
162 (Device configuration error) NOTE: Be sure to load the default settings and any additional desired settings; then, save the configuration. |
|
| 163 (Real-time clock error) |
|
| 164 (Memory configuration changed) |
|
| 184 (Power-on password damaged) |
|
| 185 (Drive startup sequence information corrupted) |
|
| 187 (VPD serial number not set) |
|
| 188 (Bad EEPROM CRC number 2) |
|
| 189 (An attempt was made to enter the system with invalid passwords) |
Run the Configuration/Setup Utility program |
| 201 (Memory test error) |
|
| 289 (DIMM disabled by the user or system) |
|
|
301 (Keyboard or keyboard controller error)
|
|
| 303 (Keyboard controller error) |
System board |
| 602 (Invalid diskette boot record) |
|
| 604 (Diskette drive error) |
|
| 662 (Diskette drive configuration error) |
|
| 962 (Parallel port error) |
|
| 11xx (System board serial port 1 or 2 error) |
|
| 1762 (Hard drive configuration error, IDE only) |
|
| 178x (Hard drive error, IDE only) |
|
| 1800 (No more hardware interrupt available for PCI adapter) |
|
| 1801 (No more ROM space available for PIC adapter) |
|
| 1962 (Drive does not contain a valid boot sector) |
|
| 5962 (IDE CD-ROM drive configuration error) |
|
| 8603 (Pointing device error) |
|
| 00012000 (Machine check architecture error) |
|
| 00019701 (Microprocessor 1 failed) |
|
| 00180200 (No more I/O space available for PCI adapter) |
|
| 00180300 (No more memory above 1MB for PCI adapter) |
|
| 00180500 (PCI option ROM checksum error) |
|
| 00180600 (PCI device BIST failure; PCI bridge error) |
|
| 00180700 (PCI device not responding) |
|
| 00181000 (General PCI error) |
|
| I9990650 (AC power has been restored) |
|
Document Location
Worldwide
Was this topic helpful?
Document Information
Modified date:
28 January 2019
UID
ibm1MIGR-44190