About cookies on this site Our websites require some cookies to function properly (required). In addition, other cookies may be used with your consent to analyze site usage, improve the user experience and for advertising. For more information, please review your options. By visiting our website, you agree to our processing of information as described in IBM’sprivacy statement. To provide a smooth navigation, your cookie preferences will be shared across the IBM web domains listed here.
Troubleshooting
Problem
POST Error Codes In the following error codes, X can be any number or letter.
Resolving The Problem
POST Error Codes
In the following error codes, X can be any number or letter.
Error Code/Symptom | FRU/Action |
062 (Three consecutive boot failures using the default configuration.) |
1. Run Configuration/Setup 2. Battery/CMOS Chip 3. System Board |
101, 102 (System and processor error) |
1. System Board 2. Processor Board |
106 (System and processor error) |
1. System Board 2. Processor Board |
111 (Channel check error) |
1. Failing ISA Adapter 2. Memory DIMM 3. System Board |
114 (Adapter read-only memory error) |
1. Failing Adapter 2. Run Diagnostics |
129 (Internal Cache error) |
1. Processor 2. Optional Processor (if installed) 3. Processor Board |
151 (Real time clock error) |
1. Run Diagnostics 2. Battery/CMOS chip 3. System Board |
161 (Real time clock battery error) |
1. Run Configuration/Setup 2. Battery/CMOS chip 3. System Board |
162 (Device Configuration Error) Important Be sure to load the default settings and any additional desired settings; then, save the configuration. |
1. Run Configuration/Setup 2. Battery/CMOS Chip 3. Failing Device 4. System Board |
163 (Real-Time Clock error) |
1. Run Configuration/Setup 2. Battery/CMOS Chip 3. System Board |
164 (Memory configuration changed, see "Memory Settings") |
1. Run Configuration/Setup 2. DIMM 3. Processor Board |
173 (System CMOS checksum bad) |
1. Run Configuration/Setup 2. Battery/CMOS Chip 3. System Board |
175 (Hardware error) |
1. System Board 2. Processor Board |
176 (Computer cover or cable cover was removed without a key being used) |
1. Run Configuration/Setup 2. System Board |
177, 178 (Security hardware error) |
1. Run Configuration/Setup 2. Service Processor Adapter 3. System Board |
184 (Power-on password corrupted) |
1. Run Configuration/Setup 2. System Board |
185 (Drive startup sequence information corrupted) |
1. Run Configuration/Setup 2. System Board |
186 | 1. Run Configuration/Setup 2. System Board |
187 (VPD serial number not set.) |
1. Set serial number in Setup 2. System Board |
188 (Bad EEPROM CRC #2) |
1. Run Configuration/Setup 2. System Board |
189 (An attempt was made to access the server with invalid passwords) |
1. Run Configuration/Setup, enter the administrator password |
195 (Processor 1 is not functioning) |
1. VRM 1 2. Processor 1 3. Processor Board 4. System Board |
196 (Processor 2 is not functioning) |
1. VRM 2 2. Processor 2 3. Processor Board 4. System Board |
197 (Processor 1 failed BIST) |
1. Processor 1 2. Processor Board 3. System Board |
198 (Processor 2 failed BIST) |
1. Processor 2 2. Processor Board 3. System Board |
201 (Memory test error, see "Memory Settings") |
1. DIMM 2. Processor Board 3. System Board |
229 (Cache error) |
1. Processor 2. Optional Processor (if installed) 3. Processor Board |
262 (DRAM parity configuration error) |
1. Run Configuration/Setup 2. Battery/CMOS Chip 3. System Board |
289 (DIMM has been disabled the user or system, see "Memory Settings") |
1. Run Configuration/Setup, if disabled by user 2. Disabled DIMM, if not disabled by user. 3. Processor Board |
301 (Keyboard or keyboard controller error) |
1. Keyboard 2. System Board |
303 (Keyboard controller error) |
1. Keyboard 2. System Board |
602 (Invalid diskette boot record) |
1. Diskette 2. Cable 3. Diskette Drive |
604 (Diskette drive error) |
1. Run Configuration/Setup and Diagnostics 2. Diskette Drive 3. Drive Cable 4. System Board |
605 (Unlock failure) |
1. Diskette Drive 2. Drive Cable 3. System Board |
662 (Diskette drive configuration error) |
1. Run Configuration/Setup and Diagnostics 2. Diskette Drive 3. Drive Cable 4. System Board |
762 (Coprocessor configuration error) |
1. Run Configuration/Setup 2. Battery/CMOS Chip 3. Processor |
962 (Parallel port error) |
1. Disconnect external cable on parallel port. 2. Run Configuration/Setup 3. System Board |
11XX (System-board serial port 1 or 2 error) |
1. Disconnect external cable on serial port. 2. Run Configuration/Setup 3. System Board |
1762 (Fixed Disk Configuration error) |
1. Fixed Disk Cables 2. Run Configuration/Setup 3. Fixed Disk Adapter 4. Fixed Disk Drive 5. System Board |
178X (Fixed Disk error) |
1. Fixed Disk Cables 2. Run Diagnostics 3. Fixed Disk Adapter 4. Fixed Disk Drive 5. System Board |
1800 (No more hardware interrupt available for PCI adapter) |
1. Run Configuration/Setup 2. Failing Adapter 3. System Board |
1801 (No room for PCI option ROM) |
1. Run Configuration/Setup 2. Failing Adapter 3. System Board |
1802 (No more I/O space available for PCI adapter) |
1. Run Configuration/Setup 2. Failing Adapter 3. System Board |
1803 (No more memory (above 1MB for PCI adapter) |
1. Run Configuration/Setup 2. Failing Adapter 3. System Board |
1804 (No more memory (below 1MB for PCI adapter) |
1. Run Configuration/Setup 2. Move the failing adapter to slot 1 or 2 3. Failing Adapter 4. System Board |
1805 (PCI option ROM checksum error) |
1. Remove Failing PCI Card 2. System Board |
1806 (PCI to PCI Bridge error) |
1. Run Configuration/Setup 2. Move the failing adapter to slot 1 or 2 3. Failing Adapter 4. System Board |
1807, 1808, 1810 (General PCI error) |
1. Remove Failing PCI Card 2. System Board |
1962 (Drive does not contain a valid boot sector) |
1. Verify a bootable operating system is installed 2. Run Diagnostics 3. Hard Disk Drive Cable 4. System Board 5. Hard Disk Drive |
2400 (Video controller test failure) |
1. Video Adapter (if installed) 2. System Board |
2462 (Video memory configuration error) |
1. Video Adapter (if installed) 2. System Board |
5962 (IDE CD-ROM configuration error) |
1. Run Configuration/Setup 2. CD-ROM Drive 3. Battery/CMOS Chip |
8603 (Pointing Device Error) |
1. Pointing Device 2. System Board |
8603 (Pointing Device Error) |
1. Pointing Device 2. System Board |
0001200 (Machine check architecture error) |
1. Processor 2. Optional Processor 3. Processor Board |
000120P0, 000120P1,000120P2,000120PF (Processor cache error) |
1. Failing Processor 2. Processor Board |
01295085 (ECC checking hardware test error) |
1. Processor Board 2. Processor |
I9990301 (Fixed boot sector error, no operating system installed) |
1. Run Configuration/Setup for correct startup 2. Verify operating system installed |
I9990305 (Fixed boot sector error, no operating system installed) |
1. Install operating system to hard disk drive. |
Document Location
Worldwide
Applicable countries and regions
- Worldwide
[{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HWN04","label":"Older System x->Netfinity 5500"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}}]
Was this topic helpful?
Document Information
More support for:
Older System x->Netfinity 5500
Document number:
844706
Modified date:
28 January 2019
UID
ibm1DDSE-42ZJ7R
Manage My Notification Subscriptions