In the following error codes, X can be any number or letter.
Error Code/Symptom | FRU/Action |
062 (Three consecutive boot failures using the default configuration.) |
1. Run Configuration/Setup 2. Battery/CMOS Chip 3. System Board |
101, 102 (System and processor error) |
1. System Board 2. Processor Board |
106 (System and processor error) |
1. System Board 2. Processor Board |
111 (Channel check error) |
1. Failing ISA Adapter 2. Memory DIMM 3. System Board |
114 (Adapter read-only memory error) |
1. Failing Adapter 2. Run Diagnostics |
129 (Internal Cache error) |
1. Processor 2. Optional Processor (if installed) 3. Processor Board |
151 (Real time clock error) |
1. Run Diagnostics 2. Battery/CMOS chip 3. System Board |
161 (Real time clock battery error) |
1. Run Configuration/Setup 2. Battery/CMOS chip 3. System Board |
162 (Device Configuration Error) Important Be sure to load the default settings and any additional desired settings; then, save the configuration. |
1. Run Configuration/Setup 2. Battery/CMOS Chip 3. Failing Device 4. System Board |
163 (Real-Time Clock error) |
1. Run Configuration/Setup 2. Battery/CMOS Chip 3. System Board |
164 (Memory configuration changed, see "Memory Settings") |
1. Run Configuration/Setup 2. DIMM 3. Processor Board |
173 (System CMOS checksum bad) |
1. Run Configuration/Setup 2. Battery/CMOS Chip 3. System Board |
175 (Hardware error) |
1. System Board 2. Processor Board |
176 (Computer cover or cable cover was removed without a key being used) |
1. Run Configuration/Setup 2. System Board |
177, 178 (Security hardware error) |
1. Run Configuration/Setup 2. Service Processor Adapter 3. System Board |
184 (Power-on password corrupted) |
1. Run Configuration/Setup 2. System Board |
185 (Drive startup sequence information corrupted) |
1. Run Configuration/Setup 2. System Board |
186 | 1. Run Configuration/Setup 2. System Board |
187 (VPD serial number not set.) |
1. Set serial number in Setup 2. System Board |
188 (Bad EEPROM CRC #2) |
1. Run Configuration/Setup 2. System Board |
189 (An attempt was made to access the server with invalid passwords) |
1. Run Configuration/Setup, enter the administrator password |
195 (Processor 1 is not functioning) |
1. VRM 1 2. Processor 1 3. Processor Board 4. System Board |
196 (Processor 2 is not functioning) |
1. VRM 2 2. Processor 2 3. Processor Board 4. System Board |
197 (Processor 1 failed BIST) |
1. Processor 1 2. Processor Board 3. System Board |
198 (Processor 2 failed BIST) |
1. Processor 2 2. Processor Board 3. System Board |
201 (Memory test error, see "Memory Settings") |
1. DIMM 2. Processor Board 3. System Board |
229 (Cache error) |
1. Processor 2. Optional Processor (if installed) 3. Processor Board |
262 (DRAM parity configuration error) |
1. Run Configuration/Setup 2. Battery/CMOS Chip 3. System Board |
289 (DIMM has been disabled the user or system, see "Memory Settings") |
1. Run Configuration/Setup, if disabled by user 2. Disabled DIMM, if not disabled by user. 3. Processor Board |
301 (Keyboard or keyboard controller error) |
1. Keyboard 2. System Board |
303 (Keyboard controller error) |
1. Keyboard 2. System Board |
602 (Invalid diskette boot record) |
1. Diskette 2. Cable 3. Diskette Drive |
604 (Diskette drive error) |
1. Run Configuration/Setup and Diagnostics 2. Diskette Drive 3. Drive Cable 4. System Board |
605 (Unlock failure) |
1. Diskette Drive 2. Drive Cable 3. System Board |
662 (Diskette drive configuration error) |
1. Run Configuration/Setup and Diagnostics 2. Diskette Drive 3. Drive Cable 4. System Board |
762 (Coprocessor configuration error) |
1. Run Configuration/Setup 2. Battery/CMOS Chip 3. Processor |
962 (Parallel port error) |
1. Disconnect external cable on parallel port. 2. Run Configuration/Setup 3. System Board |
11XX (System-board serial port 1 or 2 error) |
1. Disconnect external cable on serial port. 2. Run Configuration/Setup 3. System Board |
1762 (Fixed Disk Configuration error) |
1. Fixed Disk Cables 2. Run Configuration/Setup 3. Fixed Disk Adapter 4. Fixed Disk Drive 5. System Board |
178X (Fixed Disk error) |
1. Fixed Disk Cables 2. Run Diagnostics 3. Fixed Disk Adapter 4. Fixed Disk Drive 5. System Board |
1800 (No more hardware interrupt available for PCI adapter) |
1. Run Configuration/Setup 2. Failing Adapter 3. System Board |
1801 (No room for PCI option ROM) |
1. Run Configuration/Setup 2. Failing Adapter 3. System Board |
1802 (No more I/O space available for PCI adapter) |
1. Run Configuration/Setup 2. Failing Adapter 3. System Board |
1803 (No more memory (above 1MB for PCI adapter) |
1. Run Configuration/Setup 2. Failing Adapter 3. System Board |
1804 (No more memory (below 1MB for PCI adapter) |
1. Run Configuration/Setup 2. Move the failing adapter to slot 1 or 2 3. Failing Adapter 4. System Board |
1805 (PCI option ROM checksum error) |
1. Remove Failing PCI Card 2. System Board |
1806 (PCI to PCI Bridge error) |
1. Run Configuration/Setup 2. Move the failing adapter to slot 1 or 2 3. Failing Adapter 4. System Board |
1807, 1808, 1810 (General PCI error) |
1. Remove Failing PCI Card 2. System Board |
1962 (Drive does not contain a valid boot sector) |
1. Verify a bootable operating system is installed 2. Run Diagnostics 3. Hard Disk Drive Cable 4. System Board 5. Hard Disk Drive |
2400 (Video controller test failure) |
1. Video Adapter (if installed) 2. System Board |
2462 (Video memory configuration error) |
1. Video Adapter (if installed) 2. System Board |
5962 (IDE CD-ROM configuration error) |
1. Run Configuration/Setup 2. CD-ROM Drive 3. Battery/CMOS Chip |
8603 (Pointing Device Error) |
1. Pointing Device 2. System Board |
8603 (Pointing Device Error) |
1. Pointing Device 2. System Board |
0001200 (Machine check architecture error) |
1. Processor 2. Optional Processor 3. Processor Board |
000120P0, 000120P1,000120P2,000120PF (Processor cache error) |
1. Failing Processor 2. Processor Board |
01295085 (ECC checking hardware test error) |
1. Processor Board 2. Processor |
I9990301 (Fixed boot sector error, no operating system installed) |
1. Run Configuration/Setup for correct startup 2. Verify operating system installed |
I9990305 (Fixed boot sector error, no operating system installed) |
1. Install operating system to hard disk drive. |
Document Location
Worldwide
Applicable countries and regions
- Worldwide
[{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HWN04","label":"Older System x->Netfinity 5500"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}}]
Was this topic helpful?
Document Information
More support for:
Older System x->Netfinity 5500
Document number:
844706
Modified date:
28 January 2019
UID
ibm1DDSE-42ZJ7R
Manage My Notification Subscriptions