IBM Support

POST error codes - Netfinity 3500 M10

Troubleshooting


Problem

POST error codes

Resolving The Problem


Source
Hardware Maintenance Manual


POST error codes
In the following index, X can represent any number.

POST Error Code FRU/Action Code
000
SCSI Adapter not enabled.
1. Verify adapter device and Bus Master fields are enabled in PCI configuration
program. See documentation shipped with
computer.
02X 1. SCSI Adapter
08X
Check SCSI terminator installation.
1. SCSI Cable
2. SCSI Terminator
3. SCSI Device
4. SCSI Adapter
101
System board interrupt failure.
1. System Board
102
System board timer error.
1. System Board
106 1. System Board
110, 111
System board memory parity error.
1. Memory Module
2. System Board
114
Adapter ROM error.
1. Adapter Memory
2. System Board
121
Hardware error
1. Run Diagnostics
2. System Board
129
Internal cache test error.
1. Processor
2. L2 Cache Memory
3. System Board
151
Real-time clock failure.
1. System Board
161
Bad battery.
1. Run Setup
2. Battery (See page Safety Information )
3. System Board
162
Configuration mismatch.
1. Run Setup and verify Configuration
2. Had a device been added, removed, changed location? If not, suspect that device.
3. Power-on external devices first, then power-on computer.
4. CMOS Backup Battery
(See page Safety Information
5. System Board
163
Clock not updating or invalid time set.
1. Time and Date Set?
2. CMOS Backup Battery
(See Safety Information )
3. System Board
164
POST detected a base memory or extended memory size mismatch error.
1. Run Setup. Check System Summary menu for memory size change.
2. Run the Extended Memory Diagnostic tests.
166
Boot Block Check Sum Error
1. Run Flash Recovery using Boot Block.
2. System Board
167
Microprocessor installed that is not supported by the current POST/BIOS.
1. Run Setup. Check Stepping level for the BIOS level needed, then perform the flash update.
2. Processor
168
Alert on LAN error
1. Run Setup. Check to see that Ethernet and Alert on LAN are enabled.
2. System Board
17X, 18X 1. C2 Security


176
Covers were removed or security error was detected
1. Enter the administration password to clear the error
177
Corrupted Administrator Password.
1. System Board
183 1. Enter the administrator password
185
Corrupted boot sequence.
1. Set configuration and reinstall the boot sequence.
186
Security error has been cleared
1. N/A
187 1. Clear Administration password
2. System Board
189 1. More than three password attempts were made to access the computer.
190
Chassis intrusion detector was cleared.
This is information only, no action required.
If this code does not clear:
1. System Board
1XX
Not listed above.
1. System Board
201, 20X
Memory data error.
1. Run Enhanced Diag. Memory Test
2. Memory Module
3. System Board
225 1. Unsupported Memory
229
External cache test error.
1. L2 Cache Memory
2. System Board
262
POST detected a base memory or extended memory type error.
1. Run Setup. Check System Summary menu for memory type change.
2. Run the Extended Memory Diagnostic tests.
301 1. Keyboard
2. Keyboard Cable
3. System Board
303
With an 8603 error.
1. Mouse
2. Keyboard
3. Keyboard Cable
4. System Board
303
With no 8603 error.
1. Keyboard
2. Keyboard Cable
3. System Board
3XX
Not listed above.
1. Keyboard
2. Keyboard Cable
3. System Board
5XX 1. Video Adapter
(if installed)
2. System Board
601 1. Diskette Drive A
2. Diskette Drive Cable
3. System Board
602 1. Bad Diskette ?
2. Verify Diskette and retry.
604
And able to run diagnostics.
1. Run Setup and verify diskette configuration settings
2. Diskette Drive A/B
3. Diskette Drive Cable
4. System Board
605
POST cannot unlock the diskette drive.
1. Diskette Drive
2. Diskette Drive Cable
3. System Board
662 1. Diskette drive configuration error or wrong diskette drive type, run Setup Configuration.
6XX
Not listed above.
1. Diskette Drive
2. System Board
3. External Drive Adapter
4. Diskette Drive Cable
5. Power Supply
762
Math coprocessor configuration error.
1. Run Setup
2. Processor
3. System Board

7XX
Not listed above.
1. Processor
2. System Board
962
Parallel port configuration error.
1. Run Configuration
2. Parallel Adapter
(if installed)
3. System Board
9XX 1. Printer
2. System Board
1047 1. 16-Bit AT Fast SCSI Adapter
107X
Check SCSI terminator installation.
1. Check SCSI terminator installation.
2. SCSI Cable
3. SCSI Terminator
4. SCSI Device
5. SCSI Adapter
1101
Serial connector error, possible system board failure.
1. Run Advanced Diagnostics
1101, 1102, 1106, 1108, 1109 1. System Board
2. Any Serial Device
1107

1. Communications Cable
2. System Board

1102
Card selected feedback error.
1. Run Advanced Diagnostics
1103
Port fails register check.
1. Run Advanced Diagnostics
2. System Board
1106
Serial option cannot be turned off.
1. Run Advanced Diagnostics
2. System Board
1107 1. Serial Device Cable
2. System Board
1110
Register test failed.
1. Run Advanced Diagnostics
2. System Board
1116
Interrupt error.
1. Run Advanced Diagnostics
1117
Failed baud rate test.
1. Run Advanced Diagnostics
1162
Serial port configuration error.
1. Run Configuration
2. Serial Adapter
(if installed)
3. System Board
11XX
Not listed above.
1. System Board
1201 1. System Board
2. Any Serial Device
1202, 1206, 1208, 1209, 12XX 1. Dual Async Adapter/A
2. System Board
3. Any Serial Device
1207 1. Communications Cable
2. Dual Async Adapter/A
13XX 1. Game Adapter
1402
Printer not ready.
Information only

1403
No paper error, or interrupt failure.
Information only
1404
System board timeout failure.
1. Run Advanced Diagnostics
1405
Parallel adapter error.
1. Run Advanced Diagnostics
1406
Presence test error.
1. Run Advanced Diagnostics
14XX
Not listed above.
Check printer before replacing system board.
1. Printer
2. System Board
15XX 1. SDLC Adapter
1692
Boot sequence error.
1. Run FDISK to ensure at least one active partition is set active.
16XX 1. 36/38 Workstation Adapter
1762
Hard disk drive configuration error.
1. Run Configuration
178X
Hard disk drive test failed
1. See Power Supply
2. Hard Disk Drive
3. System Board
4. Hard Disk Cable
5. Power Supply

180X, 188X
PCI configuration or resource error.
1. Run Setup and verify PCI/ISA configuration settings.
2. If necessary, set ISA adapters to "Not available" to allow PCI adapters to properly configure.
3. Remove any suspect ISA adapters.
4. Rerun diagnostics.
5. PCI Adapter
1962
Boot sequence error.
1. Possible hard disk drive problem
209X 1. Diskette Drive
2. Diskette Cable
3. 16-bit AT Fast SCSI Adapter
20XX
Not listed above
1. BSC Adapter
21XX 1. SCSI Device
2. 16-bit AT Fast SCSI Adapter
3. Alternate BSC Adapter
2401, 2402
If screen colors change.
1. Display
2401, 2402
If screen colors are OK.
1. System Board
2. Display
2409 1. Display
2410 1. System Board
2. Display
2462
Video memory configuration error.
1. Check cable connections.
2. Run Setup and verify video configuration settings.
3. Video Memory Modules
4. Video Adapter (if installed)
5. System Board

3015, 3040
Check for missing wrap or terminator plug on the adapter.
1. Network Attached?
2. LF Translator
3. Cable Problem
4. PC Network Adapter
30XX 1. PC Network Adapter
2. LF Translator
3. Cable Problem?
3115, 3140 1. Network Attached?
2. LF Translator
3. Alternate PC Network-Adapter
4. Cable Problem
31XX 1. Alternate PC Network Adapter
2. LF Translator
3. Cable Problem?
36XX 1. GPIB Adapter
38XX 1. DAC Adapter
4611, 4630 1. Multiport/2 Interface Board
2. Multiport/2 Adapter
4612, 4613 4640, 4641 1. Memory Module Package
2. Multiport/2 Adapter
4650 1. Multiport Interface Cable
46XX
Not listed above.
1. Multiport/2 Adapter
2. Multiport/2 Interface Board
3. Memory Module
5600 1. Financial System Controller Adapter
5962
An IDE device (other than hard drive) configuration error.
1. Run Configuration
2. CD-ROM Drive
3. CD-ROM Adapter
4. ZIP or other ATAPI device
5. System Board
62XX 1. 1st Store Loop Adapter
2. Adapter Cable

63XX 1. 2nd Store Loop Adapter
2. Adapter Cable
64XX 1. Network Adapter
71XX 1. Voice Adapter
74XX 1. Video Adapter
(if installed)
76XX 1. Page Printer Adapter
78XX 1. High Speed Adapter
79XX 1. 3117 Adapter
80XX 1. PCMCIA Adapter
84XX 1. Speech Adapter
2. Speech Control Assy.
8601, 8602 1. Pointing Device
(Mouse)
2. System Board

8603, 8604 1. System Board
2. Pointing Device
(Mouse)
86XX
Not listed above
1. Mouse
2. System Board
89XX 1. PC Music Adapter
2. MIDI Adapter Unit
91XX 1. Optical Drive
2. Adapter
96XX 1. SCSI Adapter
2. Any SCSI Device
3. System Board
10101, 10102, 10104, 10105, 10106, 10107, 10108, 10109, 10111, 10112, 10113, 10114, 10115, 10116 1. Have customer verify correct operating system device drivers are installed and operational.
2. Modem
10103, 10110, 101171 1. System Board
2. Data/Fax Modem
10117
Not listed above.
1. Check system speaker
2. Check PSTN cable
3. External DAA
(if installed)
4. Modem
10118 1. Run Diagnostics and verify the correct operation of the modem slot
2. Modem
10119 1. Diagnostics detected a non-IBM modem
2. Modem

10120 1. Check PSTN Cable
2. External DAA
(if installed)
3. Modem
10132, 10133, 10134, 10135, 10136, 10137, 10138, 10139, 10140, 10141, 10142, 10143, 10144, 10145, 10146,
10147, 10148, 10149, 10150, 10151, 10152
1. Modem
10153 1. Data/Fax Modem
2. System Board
101XX
Not listed above.
1. Modem Adapter/A
2. Data/Fax Modem
3. System Board
10450, 10451, 10490, 10491, 10492, 10499
Read/write error.
1. Run Advanced Diagnostics
2. Hard Disk Drive
3. System Board
10452
Seek test error.
1. Run Advanced Diagnostics
10453
Wrong drive type?
Information only
10454
Sector buffer test error.
1. Run Advanced Diagnostics
10455, 10456
Controller error.
1. Run Advanced Diagnostics
10459
Drive diagnostic command error.
Information only

10461
Drive format error
1. Run Advanced Diagnostics
10462
Controller seek error.
1. Run Advanced Diagnostics
10464
Hard Drive read error.
1. Run Advanced Diagnostics
10467
Drive non fatal seek error.
1. Run Advanced Diagnostics
10468
Drive fatal seek error.
1. Run Advanced Diagnostics
10469
Drive soft error count exceeded.
1. Run Advanced Diagnostics
10470, 10471, 10472
Controller wrap error.
1. Run Advanced Diagnostics
10473
Corrupt data. Low level format might be required.
Information only
10480 1. Hard Disk Drive
(ESDI)
2. Drive Cable
3. System Board
10481
ESDI drive D seek error.
1. Run Advanced Diagnostics

10482
Drive select acknowledgement bad.
1. Run Advanced Diagnostics
106X1 1. Check Configuration
2. Ethernet Adapter
10635 1. Power-off computer, wait ten seconds; then power-on the computer.
2. Ethernet Adapter
10651, 10660 1. Check Cables
2. Ethernet Adapter
106XX
Not listed above.
1. Ethernet Adapter
107XX 1. 5.25-inch External Diskette Drive
2. 5.25-inch Diskette Drive Adapter/A
109XX
Check the adapter cables.
1. ActionMedia Adapter/A
2. System Board
112XX
This adapter does not have cache.
1. SCSI Adapter
2. Any SCSI Device
3. System Board
119XX 1. 3119 Adapter
121XX 1. Modem Adapter
2. Any Serial Device
3. System Board

136XX 1. ISDN Primary Rate Adapter
2. System Board
137XX 1. System Board
141XX 1. Realtime Interface Coprocessor Portmaster Adapter/A
143XX 1. Japanese Display Adapter
2. System Board
14710, 14711 1. System Board Video Adapter
2. Adapter Video Memory
148XX 1. Video Adapter
14901, 14902, 1491X, 14922 1. Video Adapter
(if installed)
2. System Board
3. Display (any type)
14932 1. External Display
2. Video Adapter
161XX 1. FaxConcentrator Adapter
164XX 1. 120 MB Internal Tape Drive
2. Diskette Cable
3. System Board

16500 1. 6157 Tape Attachment Adapter
16520, 16540 1. 6157 Streaming Tape Drive
2. 6157 Tape Attachment Adapter
166XX, 167XX 1. Token Ring Adapter
2. System Board
18001 to 18029 1. Wizard Adapter
2. Wizard Adapter Memory
18031 to 18039 1. Wizard Adapter Cable
185XXXX 1. DBCS Japanese Display Adapter/A
2. System Board
20001 to 20003 1. Image Adapter/A
Image-I Adapter/A
2. Memory Module
DRAM, VRAM
20004 1. Memory Module
DRAM, VRAM
2. Image Adapter/A
Image-I Adapter/A
20005 to 20010 1. Image Adapter/A
Image-I Adapter/A
2. Memory Module
DRAM, VRAM
200XX
Not listed above.
1. Image Adapter/A Image-I Adapter/A
2. Memory Module DRAM, VRAM
3. System Board

20101 to 20103 1. Printer/Scanner Option
2. Image Adapter/A
3. Memory Module
DRAM, VRAM
20104 1. Memory Module
DRAM, VRAM
2. Printer/Scanner Option
3. Image Adapter/A
20105 to 20110 1. Printer/Scanner Option
2. Image Adapter/A
3. Memory Module
DRAM, VRAM
Image Adapter/A
Memory Test failure indicated by graphic of adapter.
1. Replace memory module (shown in graphic.)
206XX 1. SCSI-2 Adapter
2. Any SCSI Device
3. System Board
208XX
Verify there are no duplicate SCSI ID settings on the same bus.
1. Any SCSI Device
210XXXX
Internal bus, size unknown.
210XXX1
External bus, size unknown.
1. SCSI Hard Disk Drive
2. SCSI Adapter or System Board
3. SCSI Cable
4. SCSI ID Switch
(on some models)
Tape Drive amber LED remains on. 1. Tape Drive
2. SCSI Cable (internal)
3. SCSI Adapter or System Board
Tape Drive green "in use" LED fails to come on. 1. Tape Drive
2. SCSI Adapter or System Board
3. SCSI Cable (internal)
SCSI Cable (external)
Tape automatically ejected from drive. 1. Tape Cassette
2. Drive

SCSI ID on rotary switch does not match SCSI ID set in configuration.
Verify drive switches inside cover are set to zero.
1. Rotary Switch Circuit Board
2. Circuit Board Cable
3. Tape Drive
Tape sticks/breaks in drive.
Verify that the tapes used meet ANSI standard X3B5.
1. Tape Cassette
212XX
 
1. SCSI Printer
2. Printer Cable
213XX 1. SCSI Processor
214XX 1. WORM Drive
215XXXC
215XXXD
215XXXE
215XXXU
If an external device, and power-on LED is off, check external voltages.
1. CD-ROM Drive I
CD-ROM Drive II
Enhanced CD-ROM Drive II
Any CD-ROM Drive
2. SCSI Cable
3. SCSI Adapter or System Board
216XX 1. Scanner
217XX
If an external device, and power-on LED is off, check external voltages.
1. Rewritable Optical Drive
2. SCSI Adapter or System Board
3. SCSI Cable
218XX
Check for multi CD tray, or juke box.
1. Changer
219XX 1. SCSI Communications Device

24201Y0, 24210Y0
Be sure wrap plug is attached.
1. ISDN/2 Adapter
2. ISDN/2 Wrap Plug
3. ISDN/2 Communications Cable
273XX 1. 1 Mbps Micro Channel Infrared LAN Adapter
27501, 27503
27506, 27507
1. ServerGuard Adapter
2. System Board
27502, 27504, 27510
27511, 27533, 27534
27536, 27537
1. ServerGuard Adapter
27509 1. Remove redundant adapters, run Auto Configuration program, then retest.
27512 1. WMSELF.DGS diagnostics file missing.
2. WMSELF.DGS diagnostics file incorrect.
27535 1. 3V Lithium Backup Battery
2. ServerGuard Adapter
27554 1. Internal Temperature out of range
2. ServerGuard Adapter
27555, 27556 1. ServerGuard Adapter
2. Power Supply
27558, 27559
27560, 27561
1. PCMCIA Type II Modem
2. ServerGuard Adapter

27562 1. External Power Control not connected
2. External Power Control
3. ServerGuard Adapter
27563, 27564 1. External Power Control
2. ServerGuard Adapter
275XX 1. Update Diagnostic Software
27801 to 27879 1. Personal Dictation System Adapter
2. System Board
27880 to 27889 1. External FRU
(Speaker, Microphone)
I999030X
Hard disk reset failure.
Possible hard disk drive problem

 

Document Location

Worldwide

Operating System

Older System x:Operating system independent / None

[{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HWN16","label":"Older System x->Netfinity 3500 M10"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
23 January 2019

UID

ibm1MIGR-4AUHUF