Troubleshooting
Problem
On system x3550 M4, type 7914, "Installed version: Undetected" is reported after updating the Mellanox adapter firmware (4.90.50000p6) with UXSPI. The firmware is actually updated successfully, but the version check fails.
Resolving The Problem
Source
RETAIN Tip: Not Used
Symptom
On system x3550 M4, type 7914, "Installed version: Undetected" is reported after updating the Mellanox adapter firmware (4.90.50000p6) with UXSPI.
The firmware is actually updated successfully, but the version check fails.
Affected Configurations
The system may be any of the following IBM servers:
- System x3550 M4, type 7914, any model
The system is configured with at least one of the following:
- UpdateXpress Service Pack Installer, version 10.1
The system is configured with one or more of the following IBM Option part number:
- Mellanox ConnectX-3 10 Gigabit Ethernet Adapter for IBM System x, Option part number 00D9690, any replacement part number
The UXSP build utility is affected.
The system has the symptom described above.
Note: This does not imply that the network
operating system will work under all combinations of hardware and
software.
Please see the compatibility page for more information:
http://www.ibm.com/systems/info/x86servers/serverproven/compat/us/
Solution
This behavior will be corrected in a future release of System Update Package(s) system (Mellanox MLNX_VPI update for Microsoft Windows Server x86_64 tool).
The target date for this release is scheduled for first quarter 2016.
The file is or will be available by selecting the appropriate Product Group, type of System, Product name, Product machine type, and operating system on IBM Support's Fix Central web page, at the following URL:
http://www.ibm.com/support/fixcentral/
Workaround
Use one (1) of the following workarounds:
- Use the Mellanox utility to check the updated firmware version.
- Use the Mellanox Utility to update the firmware of this adapter directly.
Additional Information
"Thyme Mellanox ConnectX- 3 10 GbE Adapter" firmware installed version is shown as undetected.
The issue can be observed by performing the following:
a. Install add-on card "Thyme Mellanox ConnectX- 3 10 GbE
Adapter".
b. Boot into OS Microsoft Windows Server 2012 R2 x64 (UEFI
mode).
c. Check Device Driver for "Thyme Mellanox ConnectX- 3 10 GbE
Adapter" installed.
d. Compare "Thyme Mellanox ConnectX- 3 10 GbE Adapter" firmware by
executing "<UXSP> compare".
e. "Installed version undetected" is shown.
There is a system Update Package(s) XML compatibility issue with the Common Information Model (CIM) provider. Users are unable to update the System Update Package(s) (Mellanox MLNX_VPI update for Windows Server x86_64 tool) due to the schedule impact with UXSP build.
Document Location
Worldwide
Was this topic helpful?
Document Information
Modified date:
30 January 2019
UID
ibm1MIGR-5099101