Troubleshooting
Problem
When AC power is lost and then returns, the system does not automatically restart and return back to its previous operational state per selection in setup.
Resolving The Problem
Source
RETAIN tip: H214531
Symptom
When AC power is lost and then returns, the system does not automatically restart and return back to its previous operational state per selection in setup.
Affected configurations
The system may be any of the following Lenovo x86 servers :
- System x3850 X6, type 6241, any model
This tip is not software specific.
This tip is not option specific.
Solution
This is a permanent limitation of the system.
Workaround
It is strongly recommended that the user installs an Uninterruptible power supply (UPS) in order to prevent the sudden loss of AC power to the system and thereby prevent this event from occurring.
Additional information
This issue occurs due to a signal race condition of the system which controls the automatic power on into the last known operational state.
The user needs to provide a remote system level auto-recovery or set an auto-restart mechanism to follow the loss of AC power. Alternatively the user can implement a UPS, which will prevent the loss of AC power to the system and thereby prevent this event from occurring.
Document Location
Worldwide
Was this topic helpful?
Document Information
Modified date:
30 January 2019
UID
ibm1MIGR-5097927