IBM Support

NC-SI Shared Port Support for Mellanox ConnectX-3 Pro ML2 (00FP650)

Troubleshooting


Problem

[This abstract has been truncated due to length constraints] The Mellanox ConnectX-3 Pro ML2 (00FP650 adapter option, FRU 00FP652), is supported for Network Controller Sideband Interface (NC-SI) for shared port with its port 1 (via channel 64) for all supported System x rack and tower server models. (where FRU = Field Replaceable Unit) To enable shared port, follow the following procedure via the system UEFI F1 setup menu: 1) From F1 main page, go to System Settings. 2) Then to Integrated ManagementModule (IMM) and select Network Configuration. 3) Next select Network Interface Port and change 'Dedicated' to 'Shared'. After saving the setting and exit F1 to boot the server into operation, the adapter port 1 will function and connected as a shared port. Note that if the system is shut down or restarted and cycled through Power On Self Test (POST), the adapter port 1 will not be continuously linked for shared port during this initiali

Resolving The Problem

Source

RETAIN tip: H213797

Symptom

The Mellanox ConnectX-3 Pro ML2 (00FP650 adapter option, replacement part number 00FP652), is supported for Network Controller Sideband Interface (NC-SI) for shared port with its port 1 (via channel 64) for all supported System x rack and tower server models.

(where replacement part number = Field Replaceable Unit)

To enable shared port, follow the following procedure via the system UEFI F1 setup menu:

  1. From F1 main page, go to System Settings.
  2. Then to Integrated Management Module (IMM) and select Network Configuration.
  3. Next select Network Interface Port and change 'Dedicated' to 'Shared'.

After saving the setting and exit F1 to boot the server into operation, the adapter port 1 will function and connected as a shared port.

Note that if the system is shut down or restarted and cycled through Power On Self Test (POST), the adapter port 1 will not be continuously linked for shared port during this initialization period. This is working as expected.

The shared port will be fully established and linked after the system power or reset cycle initialization.

Affected configurations

The system is configured with one or more of the following IBM Options:

This tip is not system specific.

This tip is not software specific.

Workaround

Not applicable.

Document Location

Worldwide

Operating System

System x Integrated Solutions:Operating system independent / None

[{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HWC20","label":"Intelligent Cluster"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
30 January 2019

UID