Troubleshooting
Problem
There is not enough shadow Random Access Memory (RAM) space for the PCI Device Option ROM (OPROM) to initialize. Unified Extensible Firmware Interface (UEFI) will inform Integrated Management Module II (IMM2) to show the error message in the IMM2 SystemEvent Log (SEL) and web interface. The IMM2 SEL shows the correct error message, but the IMM2 web interface shows unexpected characters in the diagnostic window. The unexpected characters in the diagnostic window will look like this: [I.2018002] The device found at Bus ¾Ᾱ device ¾Ᾱ Function ¾Ᾱ could not be configured due to resource constraints. The Vendor ID for the device OS ¾Ᾱ and the Device ID is ¾Ᾱ.
Resolving The Problem
Source
RETAIN tip: H205946
Symptom
There is not enough shadow Random Access Memory (RAM) space for
the PCI Device Option ROM (OPROM) to initialize.
Unified Extensible Firmware Interface (UEFI) will inform
Integrated Management Module II (IMM2) to show the error message in
the IMM2 System Event Log (SEL) and web interface. The IMM2 SEL
shows the correct error message, but the IMM2 web interface shows
unexpected characters in the diagnostic window.
The unexpected characters in the diagnostic window will look like
this:
[I.2018002] The device found at Bus ¾Ᾱ device ¾Ᾱ Function ¾Ᾱ could not be configured due to resource constraints. The Vendor ID for the device OS ¾Ᾱ and the Device ID is ¾Ᾱ.
Affected Configurations
The system can be any of the following IBM servers:
- System x3530 M4, type 7160, any model
- System x3630 M4, type 7158, any model
This tip is not software specific.
This tip is not option specific.
The following system firmware level is affected:
- Integrated Management Module II (IMM2) firmware version 1.32
The system has the symptom described above.
Solution
This behavior was corrected in the third quarter 2012 release of IMM2 firmware.
The file is available by selecting the appropriate Product group, System, Product name, Product machine type, and Operating system on IBM Support's Fix Central web page, at the following URL:
Workaround
Check the error message in the IMM2 SEL and IMM2 web interface to confirm which slot number caused OPROM to fail to initialize.
Additional Information
This issue is caused by a communication failure between UEFI and IMM2. There is no user impact because users will not know which BUS/DEV/FUNC in PCI BUS.
The IMM2 release fixed the unexpected characters displayed in
the diagnostic window.
Document Location
Worldwide
Was this topic helpful?
Document Information
Modified date:
30 January 2019
UID
ibm1MIGR-5090711