Troubleshooting
Problem
Advanced Interactive eXecutive (AIX) may report an Electrically Erasable Programmable Read-only Memory (EEPROM) error for the QLogic 2-Port 10 Gigabit Converged Network Adapter (CFFh) for IBM BladeCenter, Option part number 42C1830. Examples of the error in AIX error report: #errpt IDENTIFIER TIMESTAMP T C RESOURCE_NAME DESCRIPTION D04DA31F 0812173011 P H ent4 ADAPTER ERROR or in detail: #errpt -a LABEL: MSNENT_MPIFW_ERR Date/Time: Fri Aug 12 17:30:00 EDT 2011 Type: PERM Resource Name: ent4 Description ADAPTER ERROR Detail Data FILE NAME line: 178 file: msnent_intr.c PCI ETHERNET STATISTICS 0000 2666 0061 089B 0000 0001 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 6FAC 0000 0000 001B 1042 0000 0000 0000 6FC0 0000 05C4 0007 1671 0000 0000 0000 003C 000
Resolving The Problem
Source
RETAIN tip: H205929
Symptom
Advanced Interactive eXecutive (AIX) may report an Electrically Erasable Programmable Read-only Memory (EEPROM) error for the QLogic 2-Port 10 Gigabit Converged Network Adapter (CFFh) for IBM BladeCenter, Option part number 42C1830.
Examples of the error in AIX error report:
| #errpt | |||
| IDENTIFIER TIMESTAMP | T C RESOURCE_NAME | DESCRIPTION | |
| D04DA31F | 0812173011 P H ent4 | ADAPTER ERROR |
or in detail:
| #errpt -a LABEL: MSNENT_MPIFW_ERR Date/Time: Fri Aug 12 17:30:00 EDT 2011 Type: PERM Resource Name: ent4 Description ADAPTER ERROR Detail Data FILE NAME line: 178 file: msnent_intr.c PCI ETHERNET STATISTICS 0000 2666 0061 089B 0000 0001 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 6FAC 0000 0000 001B 1042 0000 0000 0000 6FC0 0000 05C4 0007 1671 0000 0000 0000 003C 0000 0000 0000 0E10 0000 0000 0000 0000 0000 1684 0000 005B 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0002 0000 0000 0000 0000 0000 0000 0000 0000 0000 0602 0000 113E 0000 0000 003C 003C 03AD 03AC 0396 0380 0016 0000 0000 020A 0000 0005 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 DEVICE DRIVER INTERNAL STATE 2222 2222 0000 003F 0000 0008 SOURCE ADDRESS 0000 0000 0014 Diagnostic Analysis Diagnostic Log sequence number: 45312 Resource tested: ent4 Resource Description: 10 Gb Ethernet PCI Express Dual Port Adapter (7710008077108001) Location: U78A5.001.WZS01B3-P1-C11-T1 SRN: 2E23-603 Description: ELA detected EEPROM failure. Possible replacement part numbers: ent4 replacement part number: 42C1832 U78A5.001.WZS01B3-P1-C11-T1 10 Gb Ethernet PCI Express Dual Port Adapter (7710008077108001) |
Affected configurations
The system may be any of the following IBM servers:
- BladeCenter PS700 Express, type 8406, any model
- BladeCenter PS701 Express, type 8406, any model
- BladeCenter PS702 Express, type 8406, any model
The system is configured with one or more of the following IBM Options:
- QLogic 2-Port 10 Gigabit Converged Network Adapter (CFFh) for IBM BladeCenter, Option part number 42C1830, replacement part number 42C1832
This tip is not software specific.
Solution
Update QLogic CNA firmware to version 2.00.27 or later.
The file is available by selecting the appropriate Product group, System, Product name, Product machine type, and operating system on IBM Support's Fix Central web page, at the following URL:
Additional information
This is a "FALSE" error.
The QLogic 2-Port 10 Gigabit Converged Network Adapter (CFFh) for IBM BladeCenter, Option part number 42C1830, hardware is good. Do not replace the adapter as it will not address these "FALSE" errors.
QLogic CNA firmware Level 2.00.27 has been released to address this issue.
Document Location
Worldwide
Was this topic helpful?
Document Information
Modified date:
12 April 2023
UID
ibm1MIGR-5090686