IBM Support

DSA shows slot "In Use" in " PCIe slot Information" when no device is inserted in PCIe slots - IBM System x3250 M4, x3100 M4

Troubleshooting


Problem

In the PCI Information page generated by Dynamic System Analysis (DSA) Preboot, the Slots table shows the PCIe slot "In Use" when no device is connected to the slot.

Resolving The Problem

Source

RETAIN tip: H203836

Symptom

In the PCI Information page generated by Dynamic System Analysis (DSA) Preboot, the Slots table shows the PCIe slot "In Use" when no device is connected to the slot.

Affected configurations

The system may be any of the following IBM servers:

  • System x3100 M4, type 2582, any model
  • System x3250 M4, type 2583, any model

The system is configured with at least one of the following:

  • IBM Dynamic System Analysis (DSA) 3.40, any edition
  • IBM Dynamic System Analysis (DSA) Preboot 3.40, any edition

This tip is not option specific.

Note: This does not imply that the network operating system will work under all combinations of hardware and software.

Please see the compatibility page for more information: http://www.ibm.com/systems/info/x86servers/serverproven/compat/us/

Solution

This behavior is corrected DSA 9.00.

The file is or will be available by selecting the appropriate Product name, Product machine type, and operating system on IBM Support's Fix Central web page, at the following URL:

Workaround

The user can extract the xml.gz and check the value of "CurrentUsage" of instance "IBMSG_SystemSlot":

  • If the value is 3, then the correct state is Available.
  • If the value is 4, then the correct state is In Use.

Document Location

Worldwide

Operating System

System x:Operating system independent / None

[{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QU90ACJ","label":"System x->System x3100 M4->2582"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QU90ACK","label":"System x->System x3250 M4->2583"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}}]