Troubleshooting
Problem
BladeCenter LS22, Type 7901, and BladeCenter LS42, Type 7902, with multiple Central Processing Units (CPUs) will not power up. There may or may not be an indication that an issue has occurred.
Resolving The Problem
Source
RETAIN tip: H197999
Symptom
BladeCenter LS22, Type 7901, and BladeCenter LS42, Type 7902, with multiple Central Processing Units (CPUs) will not power up.
There may or may not be an indication that an issue has occurred.
Affected configurations
The system may be any of the following IBM servers:
- BladeCenter LS22, type 7901, any model
- BladeCenter LS42, type 7902, any model
This tip is not software specific.
This tip is not option specific.
The system is configured with two (2) CPU's.
The following system firmware level(s) are affected:
- L8BT11AUS
Additional information
The Baseboard Management Controller (BMC) version 1.02 and higher addressed an issue where CPU mis-match caused inconsistent results. The BMC itself cannot alleviate the Symptom, but it can provide information about the root cause.
This Symptom may be caused by a mismatch of the CPUs installed in the blade. The BMC software will be updated to read information from the PSOC, which indicates the compatibility of the processors, and generates an alarm if the configuration is incorrect.