A system with any IBM ServeRAID 8 series adapter (8i, 8k, 8k-l,or 8s) may fail to complete Power On Self Test (POST) and will report the following message when a defective hard drive has been detected by the ServeRAID firmware:
Fatal Error: Controller Kernel PANIC !! Unknown Firmware
Error Error Code: 07
<< Press any key to continue ... >>
Controller not started
BIOS not installed!
Note: The failing hard drive will have an abnormal blinking green Light Emitting Diode (LED) while in this failing Redundant Array of Independent Disks (RAID) controller firmware condition.
Source
RETAIN tip: H196505
Symptom
A system with any IBM ServeRAID 8 series adapter (8i, 8k, 8k-l,or 8s) may fail to complete Power On Self Test (POST) and will report the following message when a defective hard drive has been detected by the ServeRAID firmware:
Fatal Error: Controller Kernel PANIC !! Unknown Firmware
Error Error Code: 07
<< Press any key to continue ... >>
Controller not started
BIOS not installed!
Note: The failing hard drive will have an abnormal blinking green Light Emitting Diode (LED) while in this failing Redundant Array of Independent Disks (RAID) controller firmware condition.
Affected configurations
The system may be any of the following IBM servers:
- BladeCenter HS21 XM, Type 1915, any model
- BladeCenter HS21 XM, Type 7995, any model
- BladeCenter HS21, Type 1885, any model
- BladeCenter HS21, Type 8853, any model
- BladeCenter LS21, Type 7971, any model
- BladeCenter LS41, Type 7972, any model
- System x3200, Type 4362, any model
- System x3200, Type 4363, any model
- System x3250, Type 4364, any model
- System x3250, Type 4365, any model
- System x3250, Type 4366, any model
- System x3400, Type 7973, any model
- System x3400, Type 7974, any model
- System x3400, Type 7975, any model
- System x3400, Type 7976, any model
- System x3550, Type 1913, any model
- System x3550, Type 7978, any model
- System x3650, Type 1914, any model
- System x3650, Type 7979, any model
- System x3655, Type 7985, any model
- System x3755, Type 7163, any model
- System x3755, Type 8877, any model
- System x3800, Type 8865, any model
- System x3800, Type 8866, any model
- System x3850, Type 8863, any model
- System x3850, Type 8864, any model
- System x3950 E, Type 8874, any model
- System x3950 E, Type 8879, any model
- System x3950, Type 8872, any model
- System x3950, Type 8878, any model
- xSeries 206m, Type 8485, any model
- xSeries 206m, Type 8490, any model
- xSeries 260, Type 8865, any model
- xSeries 306m, Type 1887, any model
- xSeries 306m, Type 8491, any model
- xSeries 306m, Type 8849, any model
- xSeries 366, Type 8863, any model
- xSeries 460, Type 8872, any model
- xSeries MXE-460, Type 8874, any model
The system is configured with one or more of the following IBM Options:
- ServeRAID-8i Controller, Option 13N2227, FRU 39R8731
- ServeRAID-8k SAS Controller, Option 25R8064, FRU 25R8076
- ServeRAID-8k-l SAS Controller, Option 39R8729, FRU 39R8731
- ServeRAID-8s SAS PCIe Controller, Option 39R8765, FRU 39R8785
This tip is not software specific.
- The ServeRAID v5.2.0-15432 firmware for the ServeRAID-8i, 8k, 8k-l and 8s controllers is affected.
The system has the symptom described above.
Solution
This behavior will be corrected in a next IBM ServeRAID-8i, 8k, 8k-l, and 8s Basic Input/Output System (BIOS)/ Firmware update version 5.2.0-15434 or newer.
The target date for this release is scheduled for Third Quarter 2010.
The referenced file will be available from the "ServeRAID Software Matrix"
Workaround
- Identify the failing hard drive location.
- Power down the server.
- Remove the defective hard drive.
- Power up the server to confirm that the array is in a critical state.
- Replace the defective hard drive.
Additional information
It was discovered that the storage BUS layer of the ServeRAID firmware was accessing an invalid pointer during the discovery of Serial Attached SCSI (SAS)/Serial Advanced Technology Attachment (SATA) drives while requesting the extended inquiry.
This issue was fixed by assigning the correct pointer during the hard drive discovery phase of the ServeRAID firmware.
BladeCenter:Operating system independent / None
System x:Operating system independent / None
Older System x:Operating system independent / None
[{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW20Y","label":"Older System x->xSeries 366"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW21H","label":"Older System x->xSeries 260"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW21J","label":"Older System x->xSeries 460"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW21M","label":"Older System x->xSeries 206m"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW21N","label":"Older System x->xSeries 306m"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW22E","label":"BladeCenter->BladeCenter HS21"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW22F","label":"BladeCenter->BladeCenter LS21"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW22G","label":"BladeCenter->BladeCenter LS41"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW22I","label":"BladeCenter->BladeCenter HS21 XM"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"LOB18","label":"Miscellaneous LOB"}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"SUNSET","label":"PRODUCT REMOVED"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW312","label":"System x->System x3800"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW314","label":"System x->System x3850"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW315","label":"System x->System x3950"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"HW316","label":"System x->System x3950 E"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW318","label":"System x->System x3550"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW319","label":"System x->System x3650"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW321","label":"System x->System x3400"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW323","label":"System x->System x3655"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW324","label":"System x->System x3755"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW329","label":"System x->System x3200"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW331","label":"System x->System x3250"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HWXA1","label":"System x->System x3650 NAS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}}]