RAID may degrade if running DSA Preboot SATA drive test - IBM BladeCenter

Troubleshooting


Problem

If the user has the following scenario: - a system with the Redundant Array of Independent Disks (RAID) created on Serial Advanced Technology Attachment (SATA) drives - IBM Dynamic System Analysis (DSA) Preboot run via F2 or via a CD image in Graphic User Interfaces (GUI) mode - LSIESG:DiskDefaultDiagnostic test executed on each drive connected to the storage controller The drive status will show -Degraded- after the user exits and reboots. This issue occurs with SATA drives on 2.5 and 3.5 inch models, but the issue cannot be seen with Serial Attached SCSI (SAS) drives. The issue can be observed on RAID Controllers MR10il V2, ServeRAID-BR10i, ServeRAID M5015, ServeRAID-MR10is, ServeRAID-MR10i.

Resolving The Problem

Source

RETAIN tip: H196326

Symptom

If the user has the following scenario:

  • a system with the Redundant Array of Independent Disks (RAID) created on Serial Advanced Technology Attachment (SATA) drives

  • IBM Dynamic System Analysis (DSA) Preboot run via F2 or via a CD image in Graphic User Interfaces (GUI) mode

  • LSIESG:DiskDefaultDiagnostic test executed on each drive connected to the storage controller

The drive status will show "Degraded" after the user exits and reboots.

This issue occurs with 2.5 and 3.5 inch SATA drives only (not seen on Serial Attached SCSI (SAS) drives). The issue can be observed on RAID Controllers MR10il V2, ServeRAID-BR10i, ServeRAID M5015, ServeRAID-MR10is, ServeRAID-MR10i, and the failure may be observed under the following condition/actions:

Environment: RAID 2 or 4 Hard Drive Disks (HDDs) together with a RAID-1 or RAID-10 configuration.

Actions:

  1. Run DSA Preboot via F2 or CD image and type GUI when prompted.
  2. Run LSIESG:DiskDefaultDiagnostic on drives in array.
  3. Exit and reboot and press CTRL+C.
  4. Check the Primary or Secondary Drive Status. It will display "Degrade".

Affected configurations

The system may be any of the following IBM servers:

  • IBM BladeCenter HS12, type 1916, any model
  • IBM BladeCenter HS12, type 8014, any model
  • IBM BladeCenter HS12, type 8028, any model
  • IBM BladeCenter HS22, type 1936, any model
  • IBM BladeCenter HS22, type 7870, any model
  • IBM BladeCenter LS22, type 7901, any model
  • IBM BladeCenter LS42, type 7902, any model
  • IBM System x3200 M2, type 4367, any model
  • IBM System x3200 M2, type 4368, any model
  • IBM System x3200 M3, type 7327, any model
  • IBM System x3200 M3, type 7328, any model
  • IBM System x3250 M2, type 4190, any model
  • IBM System x3250 M2, type 4191, any model
  • IBM System x3250 M2, type 4194, any model
  • IBM System x3250 M3, type 4251, any model
  • IBM System x3250 M3, type 4252, any model
  • IBM System x3350, type 4192, any model
  • IBM System x3350, type 4193, any model
  • IBM System x3400 M2, type 7836, any model
  • IBM System x3400 M2, type 7837, any model
  • IBM System x3500 M2, type 7839, any model
  • IBM System x3550 M2, type 4198, any model
  • IBM System x3550 M2, type 7946, any model
  • IBM System x3650 M2, type 4199, any model
  • IBM System x3650 M2, type 7947, any model
  • IBM System x3850 M2, type 7141, any model
  • IBM System x3850 M2, type 7144, any model
  • IBM System x3850 M2, type 7233, any model
  • IBM System x3850 M2, type 7234, any model
  • IBM System xiDataPlex dx360 M2 Server, type 6380, any model
  • IBM System xiDataPlex dx360 M2 Server, type 7321, any model
  • IBM System xiDataPlex dx360 M2 Server, type 7323, any model

The system is configured with at least one of the following:

  • IBM Dynamic System Analysis (DSA) Preboot 1.10, any edition
  • IBM Dynamic System Analysis (DSA) Preboot 1.11, any edition
  • IBM Dynamic System Analysis (DSA) Preboot 1.12, any edition
  • IBM Dynamic System Analysis (DSA) Preboot 1.13, any edition
  • IBM Dynamic System Analysis (DSA) Preboot 1.14, any edition
  • IBM Dynamic System Analysis (DSA) Preboot 1.15, any edition
  • IBM Dynamic System Analysis (DSA) Preboot 1.16, any edition
  • IBM Dynamic System Analysis (DSA) Preboot 2.30, any edition
  • IBM Dynamic System Analysis (DSA) Preboot 2.33, any edition
  • IBM Dynamic System Analysis (DSA) Preboot 2.34, any edition

This tip is not option specific.

The system is configured with SATA Raid.

The system's SATA Raid diagnostic did complete.

The system's SATA Raid diagnostic passes.

Note: This does not imply that the network operating system will work under all combinations of hardware and software.

Please see the compatibility page for more information: http://www.ibm.com/servers/eserver/serverproven/compat/us/

Solution

This behavior is corrected in DSA Preboot version 3.20.

The file is available on the 'IBM Support - IBM Dynamic System Analysis (DSA)' web page, at the following URL:

Workaround

  1. Do not use the DSA Preboot Diagnostics hard drive self test if the system in the RAID configuration is configured with SATA drives.
  2. Update the DSA Preboot to the latest version. The file is available on the 'IBM Support - IBM Dynamic System Analysis (DSA)' web page, at the following URL:

Additional information

Due to a data corruption issue discovered, LSI has fixed the issue and implemented the solution in their new release of function and support.

Document Location

Worldwide

Operating System

BladeCenter:Operating system independent / None

System x:Operating system independent / None

[{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QU02YET","label":"System x->System x3850 M2->7141"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"QU02YTZ","label":"System x->System x3850 M2->7144"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU056","label":"Miscellaneous"},"Product":{"code":"HW22K","label":"BladeCenter HS12"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"LOB18","label":"Miscellaneous LOB"}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QU03CKZ","label":"System x->System x3350->4193"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QU03CLB","label":"System x->System x3350->4192"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QU03CSS","label":"System x->System x3200 M2->4367"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"QU03CXP","label":"System x->System x3200 M2->4368"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QU03DBV","label":"System x->System x3250 M2->4190"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"QU03DGI","label":"System x->System x3250 M2->4194"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"QU03DKP","label":"System x->System x3250 M2->4191"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU056","label":"Miscellaneous"},"Product":{"code":"HW22K","label":"BladeCenter HS12"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"LOB18","label":"Miscellaneous LOB"}},{"Type":"HW","Business Unit":{"code":"BU056","label":"Miscellaneous"},"Product":{"code":"HW22K","label":"BladeCenter HS12"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"LOB18","label":"Miscellaneous LOB"}},{"Type":"HW","Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"HW22V","label":"BladeCenter LS22"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"LOB57","label":"Power"}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW22W","label":"BladeCenter LS42"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QU03NTU","label":"System x->System x3850 M2->7233"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"QU03NUA","label":"System x->System x3850 M2->7234"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QU03TEU","label":"System x->System x iDataPlex dx360 M2 server->7323"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QU03VIF","label":"System x->System x iDataPlex dx360 M2 server->7321"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU056","label":"Miscellaneous"},"Product":{"code":"HW21Q","label":"BladeCenter HS22"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"LOB18","label":"Miscellaneous LOB"}},{"Type":"HW","Business Unit":{"code":"BU056","label":"Miscellaneous"},"Product":{"code":"HW21Q","label":"BladeCenter HS22"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"LOB18","label":"Miscellaneous LOB"}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QU03WCX","label":"System x->System x3650 M2->7947"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QU03WKC","label":"System x->System x3550 M2->7946"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"QU03WSY","label":"System x->System x iDataPlex dx360 M2 server->6380"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"QU03WTQ","label":"System x->System x3550 M2->4198"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"QU03WTS","label":"System x->System x3650 M2->4199"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QU03XIC","label":"System x->System x3400 M2->7836"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"QU03XIF","label":"System x->System x3400 M2->7837"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QU03XIH","label":"System x->System x3500 M2->7839"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QU04FAH","label":"System x->System x3200 M3->7328"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"QU04IMI","label":"System x->System x3200 M3->7327"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QU04INM","label":"System x->System x3250 M3->4251"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QU04IOF","label":"System x->System x3250 M3->4252"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}}]