Troubleshooting
Problem
During the boot sequence of a blade, the user may encounter the following message when the LSI Serial Attached SCSI (SAS) adapter, Field Replaceable Unit (FRU) 39Y9188, is initializing: MPT BIOS Fault 11h encountered at adapter PCI.
Resolving The Problem
Source
RETAIN tip: H195930
Symptom
During the boot sequence of a blade, the user may encounter the following message when the LSI Serial Attached SCSI (SAS) adapter (39Y9190), Field Replaceable Unit (replacement part number) 39Y9188, is initializing:
| MPT BIOS Fault 11h encountered at adapter PCI. |
Affected configurations
The system is configured with one or more of the following IBM Options:
- IBM BladeCenter SAS Expansion Card CFFv (Option part number: 39Y9190, FRU part number: 39Y9188)
This tip is not hardware specific.
This tip is not software specific.
Workaround
Update the firmware and Basic Input/Output System (BIOS) of the SAS adapter to the current levels (BIOS Version 6.26.00, Firmware Version 1.27.86) or later.
Additional information
Older versions of the SAS Host Bus Adapter (HBA) BIOS may exhibit this error when scanning the SAS Connectivity module and display the above message. The updated BIOS and firmware corrects this issue.