Troubleshooting
Problem
When power cycling two system board trays in the same chassis (dx360 M2, 2U Flex chassis), a fan lower critical error can occur. Upon powering the systems back up, the system will not automatically recover from this event. This issue can be verified by the system error Light Emitting Diode (LED) being lit and the following messages being displayed in the Integrated Management Module (IMM) System Event Log (SEL): Fan, Lower Critical - going low (Fan 1 Tach reading 320 RPM with threshold 1520 RPM) Fan, Lower Critical - going low (Fan 2 Tach reading 240 RPM with threshold 1520 RPM) Fan, Lower Critical - going low (Fan 3 Tach reading 320 RPM with threshold 1520 RPM) Fan, Lower Critical - going low (Fan 4 Tach reading320 RPM with threshold 1520 RPM)
Resolving The Problem
Source
RETAIN tip: H195359
Symptom
When power cycling two system board trays in the same chassis (dx360 M2, 2U Flex chassis), a fan lower critical error can occur. Upon powering the systems back up, the system will not automatically recover from this event.
This issue can be verified by the system error Light Emitting Diode (LED) being lit and the following messages being displayed in the Integrated Management Module (IMM) System Event Log (SEL):
| Fan, Lower Critical - going low (Fan 1 Tach reading 320 RPM with threshold 1520 RPM) Fan, Lower Critical - going low (Fan 2 Tach reading 240 RPM with threshold 1520 RPM) Fan, Lower Critical - going low (Fan 3 Tach reading 320 RPM with threshold 1520 RPM) Fan, Lower Critical - going low (Fan 4 Tach reading 320 RPM with threshold 1520 RPM) |
Affected configurations
The system may be any of the following IBM Servers:
- System x iDataPlex dx360 M2 Server, type 6380, any model
- System x iDataPlex dx360 M2 Server, type 7321, any model
- System x iDataPlex dx360 M2 Server, type 7323, any model
This tip is not software specific.
This tip is not option specific.
The xCAT, ipmitool utility is affected.
The following system firmware level(s) are affected:
- IMM firmware 19E
Solution
This behavior will be corrected in a future release of IMM firmware.
The target date for this release is scheduled for second quarter 2009.
The file will be available from the IBM System x Support web site at the following URL:
| http://www.ibm.com/systems/support/ |
Workaround
To recover the system error LED, the following command would need to be run:
| ipmitool mc reset cold |
An alternative workaround to prevent this issue from occurring is to not power on/off both system boards simultaneously.
Document Location
Worldwide
Was this topic helpful?
Document Information
Modified date:
29 January 2019
UID
ibm1MIGR-5080365