Troubleshooting
Problem
While using MegaRAID Storage Manager (MSM) v2.32.00, or greater, (Client) when connected to a Linux server running MSM v2.32.00 (Full) install, after performing a warm or cold boot on the server and reopening MSM on the client machine to reconnect back to the Linux server, the user will not see the scanning of adapters and cannot see the configuration information.
Resolving The Problem
Source
RETAIN tip: H193836
Issue
While using MegaRAID Storage Manager (MSM) v2.32.00, or greater, (Client) when connected to a Linux server running MSM v2.32.00 (Full) install, after performing a warm or cold boot on the server and reopening MSM on the client machine to reconnect back to the Linux server, the user will not see the scanning of adapters and cannot see the configuration information.
Affected configurations
This tip is not hardware specific.
This tip is not option specific.
The system is configured with at least one of the following:
- MegaRAID Storage Manager, any version
Note: This does not imply that the network operating system will work under all combinations of hardware and software.
Please see the compatibility page for more information:
| http://www.ibm.com/servers/eserver/serverproven/compat/us/ |
Additional information
The user needs to restart the framework, /etc/init.d/vivaldframework restart and mrmonitor, /etc/rc.d/mrmonitor restart manually.