Troubleshooting
Problem
Serial Over LAN (SoL) is enabled and listed as ready in the Management Module (MM) or Advanced Management Module (AMM) screen, but no data appears on the screen when a SoL session begins.
Resolving The Problem
Source
RETAIN tip: H19407
Symptom
Serial Over LAN (SoL) is enabled and listed as ready in the Management Module (MM) or Advanced Management Module (AMM) screen, but no data appears on the screen when a SoL session begins.
Affected configurations
The system may be any of the following IBM servers:
- BladeCenter HS21, type 8853, any model
- BladeCenter HS21, type 1885, any model
- BladeCenter HS21 XM, type 1915, any model
- BladeCenter HS21 XM, type 7995, any model
This tip is not software specific.
This tip is not option specific.
Solution
To enable SoL for the BladeCenter HS21, so that SoL works in Basic Input/Output System (BIOS) and when booted to a supported Operating System (OS), the following settings are needed in BIOS:
Devices and I/O ports:
| Serial Port A [Auto-Configure] Serial Port B [Auto-Configure] |
Devices and I/O ports --> Remote Console Redirection:
| Remote Console Active: Enabled Remote Console Comm Port: Com 2 Baud Rate: 19200 Data Bits: 8 Parity: None Stop Bits: 1 Text Emulation: ANSI Keyboard: ANSI Active after boot: enabled Flow control: hardware |
Additional configuration is needed to enable the OS to properly interact with the SoL session.
Documentation for OS configuration and general SoL setup can be found in "Serial over LAN (SOL) Setup Guide - BladeCenter", at the following URL:
Additional information
By default, the BIOS on the BladeCenter HS21, has SoL disabled (Remote Console Active: Disabled) and unconfigured.
The Fix listed above enables SoL with proper configuration.
Document Location
Worldwide
Was this topic helpful?
Document Information
Modified date:
18 April 2023
UID