Troubleshooting
Problem
The system suddenly resets, with no apparent error code. Upon review of the system event log, the following error codes can be observed: Machine check asserted for Card or Link - SPINT, I/O Bus Interface, CPU Card, PCI-X Card Machine check asserted - SPINT, North Bridge This applies to the base install of the operating system only.
Resolving The Problem
Source
RETAIN tip: H187692
Symptom
The system suddenly resets, with no apparent error code. Upon review of the system event log, the following error codes can be observed:
| Machine check asserted for Card or Link - SPINT, I/O Bus Interface, CPU Card, PCI-X Card Machine check asserted - SPINT, North Bridge |
This applies to the base install of the operating system only.
Affected configurations
The system may be any of the following IBM servers:
- System x3800, type 8865, any model
- System x3850, type 8863, any model
- System x3950 E, type 8874, any model
- System x3950, type 8872, any model
- xSeries 260, type 8865, any model
- xSeries 366, type 8863, any model
- xSeries 460, type 8872, any model
- xSeries MXE 460, type 8874, any model
This tip is not option specific.
The system is configured with at least one of the following:
- Microsoft Windows 2003 Server, Base Install
- Microsoft Windows 2003 Server, Datacenter Edition, Base Install
Note: This does not imply that the network operating system will work under all combinations of hardware and software.
Please see the compatibility page for more information:
| http://www.ibm.com/servers/eserver/serverproven/compat/us/ |
Solution
Install Service Pack 1 or later for Microsoft Windows 2003 from the following URL:
Additional information
Microsoft Windows 2003, Service Pack 1, is a requirement for these machines. No machines with Service Pack 1 have reported this issue; furthermore, machines experiencing this issue have stopped failing upon installation of Service Pack 1.