Troubleshooting
Problem
Diagnosing POST numeric error codes
Resolving The Problem
This document is intended for trained servicers who are familiar with IBM server products. Use this document along with advanced diagnostic tests to troubleshoot problems effectively. Before servicing an IBM product, be sure to review the safety information. Click here to review safety information.
| Error Code/Symptom | FRU/Action |
|---|---|
| 062 (Three consecutive boot failures using the default configuration.) |
|
| 101, 102 (System and processor error) |
|
| ="3">106 (System and processor error) |
="3">
|
| ="3">111 (Channel check error) |
="3">
|
| ="3">114 (Adapter read only memory error) |
="3">
|
| ="3">129 (Internal Cache error) |
="3">
|
| ="3">151 (Real time clock error) |
="3">
|
| ="3">161 (Real time clock battery error) |
="3">
|
|
="8">
162 (Device configuration error) Note: Be sure to load the default settings and any additional desired settings, then, save the configuration. |
="8">
|
| ="3">163 (Real time clock error) |
="3">
|
| ="3">164 (Memory configuration changed) |
="3">
|
| ="3">173 (System CMOS checksum bad) |
="3">
|
| ="2">175 (Hardware error) |
="2">
|
| ="4">176 (Computer cover or cable cover was removed without a key being used) |
="4">
|
| ="3">177, 178 (Security hardware error) |
="3">
|
| ="3">184 (Power on password corrupted) |
="3">
|
| ="3">185 (Drive startup sequence information corrupted) |
="3">
|
| ="3">186 (Security hardware control logic failed) |
="3">
|
| ="2">187 (VPD serial number not set.) |
="2">
|
| ="2">188 (Bad EEPROM CRC number 2) |
="2">
|
| ="4">189 (An attempt was made to access the server with invalid passwords) | ="4">Run Configuration/Setup, enter the administrator password |
| ="4">195 (Processor 1 is not functioning) |
="4">
|
| ="4">196 (Processor 2 is not functioning) |
="4">
|
| ="3">197 (Processor 1 failed BIST) |
="3">
|
| ="3">198 (Processor 2 failed BIST) |
="3">
|
| ="3">201 (Memory test error) |
="3">
|
| ="3">229 (Cache error) |
="3">
|
| ="3">262 (DRAM parity configuration error) |
="3">
|
| ="5">289 (DIMM has been disabled by the user or system) |
="5">
|
| ="3">301 (Keyboard or keyboard controller error) |
="3">
|
| ="2">303 (Keyboard controller error) |
="2">
|
| ="4">602 (Invalid diskette boot record) |
="4">
|
| ="4">604 (Diskette drive error) |
="4">
|
| ="3">605 (Unlock failure) |
="3">
|
| ="4">662 (Diskette drive configuration error) |
="4">
|
| ="3">762 (Coprocessor configuration error) |
="3">
|
| ="3">962 (Parallel port error) |
="3">
|
| ="3">11XX (System-board serial port 1 or 2 error) |
="3">
|
| ="3">0001200 (Machine check architecture error) |
="3">
|
| ="2">0001295 (ECC circuit check) | ="2">Processor / PCI board |
| ="4">1301 (I²C cable to front panel not found) |
="4">
|
| ="4">1302 (I²C cable from system board to power on and reset switches not found) |
="4">
|
| ="3">1303 (I²C cable from system board to power backplane not found) |
="3">
|
| ="4">1304 (I²C cable to diagnostic LED board not found) |
="4">
|
|
="21">
1600, 1601 The system is able to communicate to the Service Processor, but the Service Processor failed to respond at the start of POST.) Do the following before replacing a FRU: If Netfinty 5100 - code 1600 ensure that a jumper is not installed on J51.
|
="21">
|
| ="6">1762 (Fixed disk configuration error) |
="6">
|
| ="5">178X (Fixed disk error) |
="5">
|
| ="3">1800 (No more hardware interrupt available for PCI adapter) |
="3">
|
| ="3">1801 (No room for PCI option ROM) |
="3">
|
| ="3">1802 (No more I/O space available for PCI adapter) |
="3">
|
| ="3">1803 (No more memory (above 1MB for PCI adapter) |
="3">
|
| ="4">1804 (No more memory (below 1MB for PCI adapter) |
="4">
|
| ="3">1805 (PCI option ROM checksum error) |
="3">
|
| ="4">1806 (PCI to PCI bridge error) |
="4">
|
| ="2">1807, 1808, 1810 (General PCI error) |
="2">
|
| ="6">1962 (Drive does not contain a valid boot sector) |
="6">
|
| ="2">2400 (Video controller test failure) |
="2">
|
| ="3">2462 (Video memory configuration error) |
="3">
|
| ="6">5962 (IDE CD-ROM configuration error) |
="6">
|
| ="2">8603 (Pointing device error) |
="2">
|
| ="4">0001200 (Machine check architecture error) |
="4">
|
| ="2">000120P0, 000120P1, 000120P2, 000120PF (Processor cache error) |
="2">
|
| ="4">00019501 (Processor 1 is not functioning - check VRM and processor LEDs) |
="4">
|
| ="4">00019502 (Processor 2 is not functioning - check VRM and processor LEDs) |
="4">
|
| ="3">00019701 (Processor 1 failed BIST) |
="3">
|
| ="3">00019702 (Processor 2 failed BIST) |
="3">
|
| ="3">00180100 (No room for PCI option ROM) |
="3">
|
| ="4">00180200 (No more I/O space available for PCI adapter) |
="4">
|
| ="4">00180300 (No more memory (above 1MB for PCI adapter)) |
="4">
|
| ="4">00180400 (No more memory (below 1MB for PCI adapter)) |
="4">
|
| ="3">00180500 (PCI option ROM checksum error) |
="3">
|
| ="4">00180600 (PCI built-in self test failure) PCI to PCI bridge error |
="4">
|
| ="2">00180700, 00180800 (General PCI error) |
="2">
|
| ="3">01295085 (ECC checking hardware test error) |
="3">
|
| ="3">01298001 (No update data for processor 1) |
="3">
|
| ="3">01298002 (No update data for processor 2) |
="3">
|
| ="3">01298101 (Bad update data for processor 1) |
="3">
|
| ="3">01298102 (Bad update data for processor 2) |
="3">
|
| ="6">I9990301 (Fixed boot sector error, no operating system installed) |
="6">
|
| ="3">I9990305 (Fixed boot sector error, no operating system installed) | ="3">Install operating system to hard disk drive. |
| ="3">I9990650 (AC power has been restored) |
="3">
|
Document Location
Worldwide
Was this topic helpful?
Document Information
Modified date:
28 January 2019
UID
ibm1MIGR-45351