IBM Support

False redundancy power error messages with RAID 5 - IBM eServer xSeries 340 and Netfinity 4500R

Troubleshooting


Problem

False redundancy power error messages with RAID 5 for the IBM eServer xSeries 340 and Netfinity 4500R.

Resolving The Problem

Source

RETAIN tip H174842

Symptom

An IBM eserver xSeries 340 or an Netfinity 4500R server (each with a RAID 5 configuration) might report either of the following two system error messages:

  • "System running non-redundant power"
  • "Recovery system running non-redundant power"

Affected configurations

  • The system might be any model of the xSeries 340, type 8656.
  • The system might be any model of the Netfinity 4500R server, type 8656.
  • The system service processor code level is 1.16 or earlier.

Solution

Download and apply the xSeries 340 and Netfinity 4500R - Advanced System Management Firmware Update, version 1.18 (or later).

Workaround

Ignore the false redundancy power error messages.

Additional information

The erroneous messages reported on either an xSeries 340 or Netfinity 4500R (each with RAID 5) will be addressed in the next release of the service processor code.
 
The reported errors are false and they may be ignored.

Document Location

Worldwide

Operating System

Older System x:Operating system independent / None

[{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW18M","label":"Older System x->xSeries 340"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HWN13","label":"Older System x->Netfinity 4500R"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}}]