Troubleshooting
Problem
POST error codes for the IBM eServer xSeries 340.
Resolving The Problem
In the following error codes, X can be any number or letter.
|
Error Code/Symptom
|
FRU/Action
|
| 062 (Three consecutive boot failures using the default configuration.) |
|
| 101, 102 (System and processor error) |
|
| 106 (System and processor error) |
|
| 111 (Channel check error) |
|
| 114 (Adapter read-only memory error) |
|
| 129 (Internal cache error) |
|
| 151 (Real time clock error) |
|
| 161 (Real time clock battery error) |
|
| 162 (Device configuration error) NOTE: Be sure to load the default settings and any additional desired settings; then, save the configuration. |
|
| 163 (Real time clock error) |
|
| 164 (Memory configuration changed, see "Memory settings" in the HMM). |
|
| 175 (Hardware error) |
|
| 176 (Computer cover or cable cover was removed without a key being used) |
|
| 177, 178 (Security hardware error) |
|
| 184 (Power-on password corrupted) |
|
| 185 (Drive startup sequence information corrupted) |
|
| 186 (Security hardware control logic error) |
|
| 187 (VPD serial number not set) |
|
| 188 (Bad EEPROM CRC #2) |
|
| 189 (An attempt was made to access the server with invalid passwords) |
|
| 201 (Memory test error, see "Memory Settings" in the HMM.) If the server does not have the latest level of BIOS installed, update the BIOS to the latest level and run the diagnostic program again. |
|
| 229 (Cache error) |
|
| 262 (DRAM parity configuration error) |
|
| 289 (DIMM has been disabled by the user or system, see "Memory settings" in the HMM.) |
|
| 301 (Keyboard or keyboard controller error) |
|
| 303 (Keyboard controller error) |
|
| 602 (Invalid diskette boot record) |
|
| 604 (Diskette drive error) |
|
| 605 (Unlock failure) |
|
| 662 (Diskette drive configuration error) |
|
| 762 (Coprocessor configuration error) |
|
| 962 (Parallel port error) |
|
| 11XX (System board serial port 1 or 2 error) |
|
| 0001200 (Machine check architecture error) |
|
| 1301 (I 2 C cable to front panel not found) |
|
| 1302 (I 2 C cable from system board to power on and reset switches not found) |
|
| 1303 (I 2 C cable from system board to power backplane not found) |
|
| 1304 (I 2 C cable to diagnostic LED board not found) |
|
|
1600
|
|
|
1601
|
|
| 1762 (Fixed disk configuration error) |
|
| 178X (Fixed disk error) |
|
| 1800 (No more hardware interrupt available for PCI adapter) |
|
| 1962 (Drive does not contain a valid boot sector) |
|
| 2400 (Video controller test failure) |
|
| 2462 (Video memory configuration error) |
|
| 5962 (IDE CD-ROM configuration error) |
|
|
8603 |
|
| 00019501 (Processor 1 is not functioning; check VRM and processor LEDs) |
|
| 00019502 (Processor 2 is not functioning; check VRM and processor LEDs) |
|
| 00019701 (Processor 1 failed ) |
|
| 00019702 (Processor 2 failed ) |
|
| 00180100 (No room for PCI option ROM) |
|
| 00180200 (No more I/O space available for PCI adapter) |
|
| 00180300 (No more memory (above 1MB for PCI adapter) |
|
| 00180400 (No more memory (below 1MB for PCI adapter) |
|
| 00180500 (PCI option ROM checksum error) |
|
| 00180600 (PCI to PCI bridge error) |
|
| 00180700, 00180800 (General PCI error) |
|
| 01295085 (ECC checking hardware test error) |
|
| 01298001 (No update data for processor 1) |
|
| 01298002 (No update data for processor 2) |
|
| 01298101 (Bad update data for processor 1) |
|
| 01298102 (Bad update data for processor 2) |
|
| I9990301 (Fixed boot sector error) |
|
| I9990305 (Fixed boot sector error; no operating system installed) |
|
| I9990650 (AC power has been restored) |
|