NOTE: In the following error codes, if XXX is 000, 195, or 197, do not replace a FRU.
The description for these error codes are:
- 000 The test passed.
- 195 The Esc key was pressed to abort the test.
- 197 This is a warning error and may not indicate a hardware failure.
For all error codes, replace/follow the FRU/Action indicated.
| Error code/symptom | FRU/Action |
| 001-198-000 (Test Aborted) |
|
| 001-XXX-000 (Failed core tests) |
System board |
| 001-XXX-001 (Failed core tests) |
System board |
|
001-250-00X |
|
| 001-250-000 (Failed system board ECC) |
System board |
| 001-250-001 (Failed system board ECC) |
System board |
| 005-XXX-000 (Failed video test) |
|
| 011-XXX-000 (Failed COM1 serial port test) |
System board |
| 015-XXX-001 (Failed USB test) |
System board |
| 015-XXX-015 (Failed USB external loopback test) |
|
| 015-XXX-198 (USB device connected during USB test) |
|
| 020-XXX-000 (Failed PCI interface test) |
System board |
| 020-XXX-001 (Failed hot-swap slot 1 PCI latch test) |
|
| 020-XXX-002 (Failed hot-swap slot 2 PCI latch test) |
|
| 020-XXX-003 (Failed hot-swap slot 3 PCI latch test) |
|
| 020-XXX-004 (Failed hot-swap slot 4 PCI latch test) |
|
| 020-XXX-005 (Failed hot-swap slot 5 PCI latch test) |
|
| 020-XXX-006 (Failed hot-swap slot 6 PCI latch test) |
|
| 030-XXX-000 (Failed Internal SCSI interface test) |
System board |
| 030-XXX-00N (Failed SCSI test on PCI slot N. Check system error log before replacing a FRU.) |
Adapter in slot N |
| 035-XXX-099 |
|
| 035-XXX-S99 (Failed RAID test on PCI slot S. S = number of failing PCI slot. Check System Error Log before replacing a FRU.) |
|
| 035-XXX-SNN (Check System Error Log before replacing a FRU. S = number of failing PCI slot; NN = SCSI ID of failing fixed disk.) |
Fixed Disk with SCSI ID NN on RAID adapter in PCI slot S. |
| 035-253-S99 (RAID adapter initialization failure) |
|
| 075-XXX-000 (Failed power supply test) |
Power supply |
| 089-XXX-001 (Failed microprocessor test) |
Microprocessor |
| 089-XXX-002 (Failed optional microprocessor test) |
Optional microprocessor 2 |
| 089-XXX-003 (Failed optional microprocessor test) |
Optional microprocessor 3 |
| 089-XXX-004 (Failed optional microprocessor test) |
Optional microprocessor 4 |
| 091-XXX-002 (Failed RXE port test) |
|
| 091-XXX-003 (Failed RXE port test) |
|
| 092-XXX-001 (Failed scalability port test) |
|
| 166-198-000 (BIOS cannot detect ASM. Reseat ASM adapter in correct slot) (ASM restart failure. Unplug and cold boot server to rest ASM) |
|
| 166-201-000 (ISMP indicates I2C errors on bus X) |
|
| 166-201-001 (ISMP indicates I2C errors on bus P) |
|
| 166-201-002 (ISMP indicates I2C errors on bus I) |
|
| 166-201-003 (ISMP indicates I2C errors on bus C) |
|
| 166-201-004 (ISMP indicates I2C errors on bus M) |
|
| 166-201-005 (ISMP indicates I2C errors on bus S) |
|
| 166-201-008 (ISMP indicates I2C errors on bus V) |
|
| 166-201-010 (ISMP indicates I2C errors on bus PCI 1) |
|
| 166-201-011 (ISMP indicates I2C errors on bus PCI 2) |
|
| 166-201-012 (ISMP indicates I2C errors on bus PCI 3) |
|
| 166-201-013 (ISMP indicates I2C errors on bus PCI 4) |
|
| 166-201-014 (ISMP indicates I2C errors on bus PCI 5) |
|
| 166-201-015 (ISMP indicates I2C errors on bus PCI 6) |
|
| 166-201-100 (ISMP indicates I2C errors on RXE bus X) |
Refer to Hardware Maintenance Manual for IBM RXE-100 Remote Expansion Enclosure |
| 166-201-101 (ISMP indicates I2C errors on RXE bus P) |
Refer to Hardware Maintenance Manual for IBM RXE-100 Remote Expansion Enclosure |
| 166-201-102 (ISMP indicates I2C errors on RXE bus I_A) |
Refer to Hardware Maintenance Manual for IBM RXE-100 Remote Expansion Enclosure |
| 166-201-103 (ISMP indicates I2C errors on RXE bus I_B) |
Refer to Hardware Maintenance Manual for IBM RXE-100 Remote Expansion Enclosure |
| 166-201-104 (ISMP indicates I2C errors on RXE bus PCI_A) |
Refer to Hardware Maintenance Manual for IBM RXE-100 Remote Expansion Enclosure |
| 166-201-105 (ISMP indicates I2C errors on RXE bus F) |
Refer to Hardware Maintenance Manual for IBM RXE-100 Remote Expansion Enclosure |
| 166-201-106 (ISMP indicates I2C errors on RXE bus PCI_B) |
Refer to Hardware Maintenance Manual for IBM RXE-100 Remote Expansion Enclosure |
| 166-201-107 (ISMP indicates I2C errors on RXE bus PCI_A slot 1) |
Adapter in slot A1 |
| 166-201-108 (ISMP indicates I2C errors on RXE bus PCI_A slot 2) |
Adapter in slot A2 |
| 166-201-109 (ISMP indicates I2C errors on RXE bus PCI_A slot 3) |
Adapter in slot A3 |
| 166-201-110 (ISMP indicates I2C errors on RXE bus PCI_A slot 4) |
Adapter in slot A4 |
| 166-201-111 (ISMP indicates I2C errors on RXE bus PCI_A slot 5) |
Adapter in slot A5 |
| 166-201-112 (ISMP indicates I2C errors on RXE bus PCI_A slot 6) |
Adapter in slot A6 |
| 166-201-113 (ISMP indicates I2C errors on RXE bus PCI_B slot 1) |
Adapter in slot B1 |
| 166-201-114 (ISMP indicates I2C errors on RXE bus PCI_B slot 2) |
Adapter in slot B2 |
| 166-201-115 (ISMP indicates I2C errors on RXE bus PCI_B slot 3) |
Adapter in slot B3 |
| 166-201-116 (ISMP indicates I2C errors on RXE bus PCI_B slot 4) |
Adapter in slot B4 |
| 166-201-117 (ISMP indicates I2C errors on RXE bus PCI_B slot 5) |
Adapter in slot B5 |
| 166-201-118 (ISMP indicates I2C errors on RXE bus PCI_B slot 6) |
Adapter in slot B6 |
| 166-250-000 (I2C cable disconnected) |
Reconnect/reseat I2C cable between remote service adapter and system board |
| 166-260-000 (ASM restart failure) |
|
| 166-342-000 (system management BIST indicates failed tests) |
|
| 166-400-000 (ISMP Self Test Result failed tests: xxx) where xxx = flash, ROM, or RAM |
|
| 166-400-100 (DMC Self Test Result failed tests: xxx) where xxx = flash, ROM, or RAM |
|
| 175-XXX-000 (Fan failure) |
|
| 180-361-003 (Fan LED test) |
|
| 180-XXX-000 (Diagnostics LED failure) |
Run Diagnostic LED test for the failing LED |
| 180-XXX-001 (Failed front LED panel test) |
|
| 180-XXX-002 (Failed diagnostics LED panel test) |
|
| 180-XXX-003 (Failed system board LED test) |
System board |
| 180-XXX-005 (Failed SCSI backplane LED test) |
|
| 180-XXX-006 (Memory board LED test) |
|
| 180-XXX-031 (RXE PCI-X backplane LED test) |
|
| 180-XXX-032 (RXE operator panel LED test) |
|
| 180-XXX-033 (RXE fans LED test) |
|
| 180-XXX-034 (RXE backplane LED test) |
|
| 180-XXX-035 (RXE PCI-X backplane LED test) |
|
| 201-XXX-0NN (Failed Memory test, see "Memory Settings" in the Hardware Maintenance Manual.) NN = DIMM location. |
|
| 201-XXX-999 (Multiple DIMM failure, see error text.) |
|
| 202-XXX-001 (Failed processor cache test) |
Microprocessor 1 |
| 202-XXX-002 (Failed processor cache test) |
Microprocessor 2 |
| 202-XXX-003 (Failed processor cache test) |
Microprocessor 3 |
| 202-XXX-004 (Failed processor cache test) |
Microprocessor 4 |
| 203-XXX-000 (External cache aborted) |
Not supported |
| 206-XXX-000 (Failed diskette drive test) |
|
| 215-XXX-000 (Failed IDE CD-ROM test) |
|
|
217-XXX-000 NOTE: If RAID is configured, the fixed disk number refers to the RAID logical array. |
Fixed disk 1 |
|
217-XXX-001 NOTE: If RAID is configured, the fixed disk number refers to the RAID logical array. |
Fixed disk 2 |
|
217-XXX-002 NOTE: If RAID is configured, the fixed disk number refers to the RAID logical array. |
Fixed disk 3 |
| 217-198-XXX (could not establish drive parameters) |
|
| 264-XXX-0NN (NN = SCSI ID of failing tape drive) |
|
| 264-XXX-999 (Errors on multiple tape drives, see error text for more info) |
See error messages/text in the PC Doctor error log for detailed information on each individual tape drive error. |
| 301-XXX-000 (Failed keyboard test) |
Keyboard |
| 405-XXX-000 (Failed Ethernet test on controller on the system board) |
|
| 405-XXX-00N (Failed Ethernet test on adapter in PCI slot N) |
|
| 415-XXX-000 (Failed modem test) |
|
Document Location