Troubleshooting
Problem
Diagnosing POST numeric error codes on the IBM eServer xSeries 370
Resolving The Problem
In the following error codes, X can be any number or letter.
|
Error Code/Symptom
|
FRU/Action
|
|---|---|
| 062 (Three consecutive boot failures using the default configuration.) |
1. Run Configuration/Setup 2. Battery 3. I/O function card |
| 101, 102, 106 (System and processor error) |
1. I/O board 2. Processor controller board 3. Processor daughterboard |
| 106 (Diskette controller error) |
1. I/O function card 2. I/O board |
| 111 (Channel check error) |
I/O board |
| 114 (Adapter read-only memory error) |
1. Failing adapter 2. Run diagnostics |
| 129 (Internal cache error) |
1. BSP Processor |
| 151 (Real time clock error) |
1. Run Diagnostics 2. Battery 3. I/O function card |
| 161 (Real time clock battery error) |
1. Run Configuration/Setup 2. Battery 3. I/O function card |
| 162 (Device Configuration Error) Note: Be sure to load the default settings and any additional desired settings; then, save the configuration. |
1. Run Configuration/Setup 2. Battery 3. Failing device identified by displayed error message 4. I/O board 5. Media power cable |
| 163 (Real-Time Clock error) |
1. Run Configuration/Setup 2. Battery 3. I/O function card |
| 164 (Memory configuration changed, see Memory settings in the HMM). |
1. If error 289 is displayed, follow instruction on screen. Verify failing FRU in system error log. 2. Run Configuration/setup 3. DIMM 4. Memory Card 5. Processor daughterboard 6. Processor controller board |
| 173 (System CMOS checksum bad) |
1. Run Configuration/Setup 2. Battery 3. I/O function card |
| 175 (Hardware error) |
1. System Management adapter 2. I/O board 3. Processor daughterboard 4. Processor controller board |
| 176 (Computer cover or cable cover was removed without a key being used) |
1. Run Configuration/Setup 2. Intrusion cable (if in a tower configuration) 3. Front panel cable 4. Front panel 5. I/O function card |
| 177, 178 (Security hardware error) |
1. Run Configuration/Setup 2. Intrusion cable (if in a tower configuration) 3. Front panel cable 4. Front panel 5. I/O function card 6. System Management adapter 7. System Management adapter cable |
| 184 (Power-on password corrupted) |
1. Run Configuration/Setup 2. Battery 3. System Management adapter |
| 185 (Drive startup sequence information corrupted) |
1. Run Configuration/Setup 2. System Management adapter |
| 186 (Security control logic error) |
1. Run Configuration/Setup 2. Intrusion cable (if in a tower configuration) 3. Front panel cable 4. Front panel 5. I/O function card 6. System Management adapter |
| 187 (VPD serial number not set.) |
1. Set serial number in Setup 2. System Management adapter |
| 188 (Bad EEPROM CRC #2) |
1. Run Configuration/Setup 2. I/O board |
| 189 (An attempt was made to access the server with invalid passwords) |
Run Configuration/Setup, enter the administrator password |
| 201 (Memory test error) |
1. DIMM 2. Memory board 3. Processor controller board 4. Processor daughterboard |
| 229 (Cache error) |
1. BSP Processor NOTE: The BSP Processor is identified on the IBM logo screen during boot. If you cannot boot to the IBM logo screen, the BSP is the highest functional processor (highest functioning processor slot number) on the processor daughterboard A. 2. Processor controller board 3. Processor daughterboard |
| 262 (DRAM parity configuration error) |
1. Run Configuration/Setup 2. Battery 3. Processor controller board 4. Processor daughterboard |
| 289 (DIMM has been disabled by user or system, see Memory settings in the HMM.) |
1. Follow instructions on screen. Verify failing FRU in system error log. |
| 301 (Keyboard or keyboard controller error) |
1. Keyboard 2. I/O function card 3. I/O board |
| 303 (Keyboard controller error) |
1. Keyboard 2. I/O function card 3. I/O board |
| 602 (Invalid diskette boot record) |
1. Diskette media 2. Check drive cable 3. Diskette drive 4. Media power cable 5. I/O function card |
| 604 (Diskette drive error) |
1. Run Configuration/Setup and Diagnostics 2. Check drive cable 3. Diskette drive 4. Media power cable 5. I/O function card |
| 605 (Unlock failure) |
1. Check drive cable 2. Diskette drive 3. Media power cable 4. I/O function card |
| 662 (Diskette drive configuration error) |
1. Run Configuration/Setup and Diagnostics 2. Check drive cable 3. Diskette drive 4. Media power cable 5. I/O function card |
| 962 (Parallel port error) |
1. Disconnect external cable on parallel port. 2. Run Configuration/Setup 3. I/O function card |
| 11XX (System board serial port 1 or 2 error) |
1. Disconnect external cable on serial port. 2. Run Configuration/Setup 3. I/O function card |
| 1600 (System Management adapter is not functioning) Do the following before replacing a FRU: Remove the ac power to the system, wait 20 seconds; then, reconnect the ac power. Wait 30 seconds; then, power-on the system. |
1. I/O board cable 2. System Management adapter cable 3. System Management adapter 4. I/O function card 5. I/O board |
| 1762 (Fixed disk configuration error) |
1. Fixed disk cables 2. Run Configuration/Setup 3. Fixed disk adapter 4. Fixed disk drive 5. I/O function card |
| 178X (Fixed disk configuration error) |
1. Fixed disk cables 2. Run Diagnostics 3. Fixed disk adapter 4. Fixed disk drive 5. I/O function card |
| 1800 (No more hardware interrupt available for PCI adapter) |
1. See system error log 2. See error code 001800XX |
| 1800 (No more hardware interrupt available for PCI adapter) |
1. See system error log 2. See error code 001801XX |
| 1801 (No room for PCI option ROM) |
1. See system error log 2. See error code 001802XX |
| 1802 (No more I/O space available for PCI adapter) |
1. See system error log 2. See error code 001800XX |
| 1803 (No more memory above 1MB available for PCI adapter) |
1. See system error log 2. See error code 001803XX |
| 1804 (No more memory below 1MB available for PCI adapter) |
1. See system error log 2. See error code 001804XX |
| 1805 (PCI option ROM checksum error) |
1. See system error log 2. See error code 001805XX |
| 1806 (PCI to PCI bridge error) |
1. See system error log 2. See error code 001806XX |
| 1807 (PCI device not responding) |
1. See system error log 2. See error code 001807XX |
| 1808 (Unsupported PCI device error) |
1. See system error log 2. See error code 001808XX |
| 1962 (Drive does not contain a valid boot sector) |
1. Verify a bootable operating system is installed. 2. Run Diagnostics 3. Internal SCSI drive cable, if internal boot device; external SCSI drive cable, in external boot device 4. I/O function card 5. Hard disk drive |
| 2400 (Video controller test failure) |
1. Video Adapter (if installed) 2. I/O function card |
| 2462 (Video memory configuration error) |
1. Video Adapter (if installed) 2. I/O function card |
| 5962 (IDE CD-ROM configuration error) |
1. Run Configuration/Setup 2. CD-ROM drive cable 3. CD-ROM drive 4. Media power cable 5. Battery 6. I/O function card |
|
8603 |
1. Pointing device 2. I/O function card |
| 00012000 (Machine check architecture error) |
1. BSP processor NOTE: The BSP Processor is identified on the IBM logo screen during boot. If you cannot boot to the IBM logo screen, the BSP is the highest functional processor (highest functioning processor slot number) on the processor daughterboard A. 2. Processor controller board 3. Processor daughterboard |
| 000195A01 (Processor A1 is not functioning) |
1. Cache coherency filter DIMMs (if applicable) 2. Processor A1 3. Processor daughterboard A 4. Processor controller board |
| 000195A02 (Processor A2 is not functioning) | 1. Cache coherency filter DIMMs (if applicable) 2. Processor A2 3. Processor daughterboard A 4. Processor controller board |
| 000195A03 (Processor A3 is not functioning) |
1. Cache coherency filter DIMMs (if applicable) 2. Processor A3 3. Processor daughterboard A 4. Processor controller board |
| 000195A04 (Processor A4 is not functioning) |
1. Cache coherency filter DIMMs (if applicable) 2. Processor A4 3. Processor daughterboard A 4. Processor controller board |
| 000195B01 (Processor B1 is not functioning) |
1. Cache coherency filter DIMMs (if applicable) 2. Processor B1 3. Processor daughterboard B 4. Processor controller board |
| 000195B02 (Processor B2 is not functioning) |
1. Cache coherency filter DIMMs (if applicable) 2. Processor B2 3. Processor daughterboard B 4. Processor controller board |
| 000195B03 (Processor B3 is not functioning) |
1. Cache coherency filter DIMMs (if applicable) 2. Processor B3 3. Processor daughterboard B 4. Processor controller board |
| 000195B04 (Processor B4 is not functioning) |
1. Cache coherency filter DIMMs (if applicable) 2. Processor B4 3. Processor daughterboard B 4. Processor controller board |
| 000197B01 (Processor B1 failed BIST) |
1. Processor B1 2. Processor daughterboard B 3. Processor controller board |
| 000197B02 (Processor B2 failed BIST) |
1. Processor B2 2. Processor daughterboard B 3. Processor controller board |
| 000197B03 (Processor B3 failed BIST) |
1. Processor B3 2. Processor daughterboard B 3. Processor controller board |
| 000197B04 (Processor B4 failed BIST) |
1. Processor B4 2. Processor daughterboard B 3. Processor controller board |
| 000197A01 (Processor A1 failed BIST) |
1. Processor A1 2. Processor daughterboard A 3. Processor controller board |
|
000197A02 |
1. Processor A2 2. Processor daughterboard A 3. Processor controller board |
| 000197A03 (Processor A3 failed BIST) |
1. Processor A3 2. Processor daughterboard A 3. Processor controller board |
| 000197A04 (Processor A4 failed BIST) |
1. Processor A4 2. Processor daughterboard A 3. Processor controller board |
| 00019900A (Processor bus A disabled) |
1. Cache coherency filter DIMMs 2. Processor daughterboard A 3. Processor controller board |
|
00019900B |
1. Cache coherency filter DIMMs 2. Processor daughterboard B 3. Processor controller board |
| 001800XX (No more hardware interrupt available for PCI adapter) |
1. Run Configuration/Setup 2. Try adapter in another PCI slot 3. Failing adapter 4. I/O function card |
|
001801XX NOTE: Adapters have too many ROMs. Reduce number of PCI adapters or disable their ROMs. The last two digits identify the PCI slot of the suspect adapter. |
1. Run Configuration/Setup 2. Failing adapter 3. I/O function card 4. I/O board |
| 001802XX (No more I/O space available for PCI adapter) The last two digits identify the PCI slot of the suspect adapter. |
1. Run Configuration/Setup 2. Failing adapter 3. I/O function card |
| 001803XX (No more memory above 1MB available for PCI adapter) The last two digits identify the PCI slot of the suspect adapter. |
1. Run Configuration/Setup 2. Failing adapter 3. I/O board |
| 001804XX (No more memory below 1MB available for PCI adapter) The last two digits identify the PCI slot of the suspect adapter. |
1. Run Configuration/Setup 2. Move the failing adapter to slot 11 or 12 3. Failing adapter |
| 001805XX (PCI option ROM checksum error) The last two digits identify the PCI slot of the suspect adapter. |
1. PCI adapter 2. I/O board |
| 001806XX (PCI to PCI bridge error) The last two digits identify the PCI slot of the suspect adapter. |
1. Run Configuration/Setup 2. Move the failing adapter to slot 1 or 2 3. Failing adapter 4. I/O function card |
| 001807XX (PCI device not responding) The last two digits identify the PCI slot of the suspect adapter. |
If the adapter slot power LED is on, suspect FRUs in this order: If the adapter slot power LED is off, suspect FRUs in this order: |
| 001808XX (Unsupported PCI device error) The last two digits identify the PCI slot of the suspect adapter. |
1. PCI adapter 2. I/O board |
| 01295085 (ECC checking hardware test error) |
1. Processor controller board 2. Processor daughterboard 3. BSP processor 4. Run memory diagnostics |
| 01299XXX (Hardware configuration has changed or the VPD information stored on the System Management Adapter has been corrupted) If no hardware has been changed, suspect the System Management Adapter and replace FRUs as listed. If hardware has been changed, this code is only informative and is not an error. |
1. Check the System Management adapter cable 2. System Management adapter 3. I/O function card 4. I/O board |
| I9990301 (Fixed boot sector error, no operating system installed) |
1. Run Configuration/Setup for correct startup 2. Verify operating system installed 3. Internal SCSI drive cable, if internal boot device; external SCSI drive cable, in external boot device 4. SCSI drive 5. SCSI Backplane 6. I/O function card |
| I9990305 (Fixed boot sector error, no operating system installed) |
Install operating system to hard disk drive. |