Troubleshooting
Problem
SCSI errors
Resolving The Problem
SCSI errors| Error Code | FRU/Action |
| Internal SCSI hard drive does not configure on boot |
1. Run Set-up/Configuration Utility. 2. Run SCSI Select Utility. 3. Suspect FRUs in the following order: a. SCSI cable b. Media Power cable c. Hard file d. I/O Function card e. SCSI backplane |
| External SCSI device does not configure on boot One or more of the following might be causing the problem: |
|
| Internal SCSI device status LED stays lit constantly |
|
| Error Code | FRU/Action |
| Negotiation failed |
b. SCSI cable c. SCSI backplane 2 . If the system does not fail with the SCSI cable plugged into the other SCSI port, replace the I/O function card. |
| Wide negotiation failed |
b. SCSI cable c. SCSI backplane 2. If the system does not fail with the SCSI cable plugged into the other SC SI port, replace the I/O function card. |
| Termination error or faulty cable |
1. Swap the SCSI cable on the I/O function card to the other SCSI port and reboot system. If the failure is the same as before, suspect FRUs in the following order: a. DASD drive b. SCSI cable c. SCSI backplane 2. If the system does not fail with the SCSI cable plugged into the other SCSI port, replace the I/O function card. |