Download
Version
11.2.1193.38-1
Release Date
21 September 2017
Downloadable File
| File link | File size | File description |
|---|---|---|
| 6,968,616 | Emulex OCe14xxx UCNA Firmware Update for Windows - 11.2.1193.38 - Release 17A | |
| 12,594 | CHANGE HISTORY for the Emulex OCe14xxx UCNA Firmware Update for Windows - 11.2.1193.38 - Release 17A | |
| 11,203 | README for the Emulex OCe14xxx UCNA Firmware Update for Windows - 11.2.1193.38 - Release 17A | |
| 21,756 | XML for the Emulex OCe14xxx UCNA Firmware Update for Windows - 11.2.1193.38 - Release 17A |
Abstract
Download the latest Emulex OCe14xxx UCNA Firmware Update for Windows.
Download Description
Change history
Severity: Suggested
Version: 11.2.1193.38-1
Emulex OCe14xxx UCNA Firmware Package
Supported On:
- System x Rack
- Flex
Problems Fixed:
- None
Incremental Interoperability:
- RHEL7 Update 3 Support
- SLES12 SP2 Support
- Windows 2016 Support
- VMware ESXi 6.5 Support
Known Issues:
- Server hangs at "Scan for Fibre Devices," when port disable/enable is performed on the Brocade Converged 10 Gb Ethernet Switch Module for IBM BladeCenter. Do not force the link down after POST has completed and then attempt a discovery of the SAN. If you do, a reboot is needed. (159125)
- To disable BFS after BOFM or IFM have been enabled, it must be done by setting BFS manually in the EFIBoot config utility or sending a BOFM default command to the port. This is working as expected and we are documenting it here. (159505)
- Intermittently, 255 vPorts cannot be created successfully in Windows with the error "ERROR: <127>: Not enough HBA or fabric resources. VPort not created!" There is no known workaround other than to reduce the number of configured vPorts. (155807)
- Target login will fail if you dynamically reconfigure the SAN after POST has executed. If you do, then reboot the system. (159121)
- IFM Boot target is consumed on a particular port even though the target is not accessible to that port. IFM/BOFM boot target configuration is not supported. This limitation has existed for several code releases and we are now documenting it here. (159226)
- The server may hang at "Connecting Boot Devices and Adapters" if both FCoE ports have boot targets configured when using a 10Gb Ethernet Pass-Thru Module for IBM BladeCenter. The server will not hang if only a single port is configured with a boot target. (157137)
- In FCoE configurations with BE3 in UFP mode on System x3690 X5 servers, a UEFI rescan is required to boot to the OS. This renders UFP not supportable in UFP/FCoE configurations. (158669)
- After making changes to any options in the sub-menus under 'controller configuration' in the Emulex UEFI NIC configuration utility and escaping to the prior menu, there is no prompt to save the changes. Be sure to select 'Save' before exiting the configuration menu. Applies to some legacy rack and blade servers.
- Intermittently, when changing the multichannel mode, the system will not auto-reboot after exiting F1 UEFI setup and will continue through POST. Manually reboot the server to ensure all changes are applied. Applies to some legacy rack and blade servers.
- When using a Cisco Nexus 4001i Switch Module, intermittently the 10Gb link may come up as 1Gb link speed. An internal switch port bounce will typically establish a 10Gb link. Setting the switch port speed to fixed 10000 will also allow a guaranteed 10Gb connection. More info is available in the Cisco Nexus 4001i Switch Module firmware release notes.
- When modifying configuration values for an iSCSI target, attempting to save the target with any invalid values may result in all values for that target being cleared. If this occurs, re-add the target using only valid configuration values. Please consult the Emulex Boot Manual for a description of valid configuration values.
Note: See the change history file for more information.
Off
Document Location
Worldwide
[{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QU01DEW","label":"System x->System x3500 M4->7383"},"Platform":[{"code":"PF033","label":"Windows"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QU01DKP","label":"System x->System x3650 M4->7915"},"Platform":[{"code":"PF033","label":"Windows"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU050","label":"BU NOT IDENTIFIED"},"Product":{"code":"QU01GQR","label":"PureFlex System and Flex System->x240 Compute Node->7863"},"Platform":[{"code":"PF033","label":"Windows"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"QU01GRH","label":"PureFlex System and Flex System->x240 Compute Node->8737"},"Platform":[{"code":"PF033","label":"Windows"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QU91IPI","label":"System x->System x3550 M4->7914"},"Platform":[{"code":"PF033","label":"Windows"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"QUOEDBG","label":"PureFlex System and Flex System->x240 Compute Node->8738"},"Platform":[{"code":"PF033","label":"Windows"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QUOEKUB","label":"System x->System x3250 M5->5458"},"Platform":[{"code":"PF033","label":"Windows"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QUOEVPK","label":"System x->System x3850 X6->3837"},"Platform":[{"code":"PF033","label":"Windows"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QUOEVSH","label":"System x->System x3950 X6->3837"},"Platform":[{"code":"PF033","label":"Windows"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QUOEVSP","label":"System x->System x3950 X6->3839"},"Platform":[{"code":"PF033","label":"Windows"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU050","label":"BU NOT IDENTIFIED"},"Product":{"code":"QUOEZVT","label":"PureFlex System and Flex System->x280 X6 Compute Node->4259"},"Platform":[{"code":"PF033","label":"Windows"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU050","label":"BU NOT IDENTIFIED"},"Product":{"code":"QUOEZVV","label":"PureFlex System and Flex System->x480 X6 Compute Node->4259"},"Platform":[{"code":"PF033","label":"Windows"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU050","label":"BU NOT IDENTIFIED"},"Product":{"code":"QUOEZVX","label":"PureFlex System and Flex System->x880 X6 Compute Node->4259"},"Platform":[{"code":"PF033","label":"Windows"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU050","label":"BU NOT IDENTIFIED"},"Product":{"code":"QUOEZZB","label":"PureFlex System and Flex System->x880 X6 Compute Node->7903"},"Platform":[{"code":"PF033","label":"Windows"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU050","label":"BU NOT IDENTIFIED"},"Product":{"code":"QUOEZZD","label":"PureFlex System and Flex System->x280 X6 Compute Node->7903"},"Platform":[{"code":"PF033","label":"Windows"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU050","label":"BU NOT IDENTIFIED"},"Product":{"code":"QUOEZZG","label":"PureFlex System and Flex System->x480 X6 Compute Node->7903"},"Platform":[{"code":"PF033","label":"Windows"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"QUOFECN","label":"System x->System x3850 X6->3839"},"Platform":[{"code":"PF033","label":"Windows"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"QUOFHZ9","label":"PureFlex System and Flex System->x240 Compute Node (8956-15X)->8956"},"Platform":[{"code":"PF033","label":"Windows"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"QUOFM3R","label":"PureFlex System and Flex System->x240 Compute Node->8956"},"Platform":[{"code":"PF033","label":"Windows"}],"Line of Business":{"code":"","label":""}}]