IBM Support

ServeRAID M5100 Series SAS/SATA controller firmware update v23.7.0-0029 - IBM System x

Download


Version

23.7.0-0029

Release Date

29 May 2014

Downloadable File

File link File size File description
5,568,775 ServeRAID M5100 Series SAS/SATA Controller Firmware Update
4,827 CHANGE HISTORY for the ServeRAID M5100 Series SAS/SATA Controller Firmware Update
5,100 Readme file for the ServeRAID M5100 Series SAS/SATA Controller Firmware Update
15,034 XML for the ServeRAID M5100 Series SAS/SATA Controller Firmware Update

Abstract

Download the latest ServeRAID M5100 Series SAS/SATA Controller Firmware Update

Download Description

Change history

ServeRAID M5100 Series SAS/SATA Controller Firmware Update for Linux

Adapters Supported

  • ServeRAID M5110 SAS/SATA Controller for IBM System x (81Y4481)
  • ServeRAID M5110e SAS/SATA Controller for IBM System x
  • ServeRAID M5120 SAS/SATA Controller for IBM System x (81Y4478)

Severity Suggested

Version 23.7.0-0029

Enhancements

  • Added support for Cache Cade 2.1
  • Added Support for PI Drives

Fixes

  • Fixed an issue where the firmware reports device initialization completion status to be greater than 100% at startup.
  • Fix an issue where when a secure foreign drive was present, VD creation fails because firmware becomes unresponsive
  • Added a check for the presence of PD before writing the data arms of a protected LD during BGI.
  • Fixed Firmware asserts in CacheMemAllocForPrebootApps() when memory was allocated twice by BIOS.
  • Fixed an issue with USB Cacheoffload restore fails after multiple power cycles on ServeRAID M51xx controllers.
  • Fixed an issue where querying SMART / PFA Status returns "all zeros" in Sense Data.
  • Fixed an issue where the import of a config from MR to iMR resulted in a firmware crash.
  • Fixed an issue where iMR firmware crashed while creating 8/16/32 KB stripe size Lds.
  • Fixed background initialization watermark conversion to PD LBA.
  • Fixed write protected R1E data arms during initialization.
  • Fixed an issue where MR firmware crashed while discarding pinned cache.
  • Fixed an issue where a dirty LD dependency information of SSD pd has stale entries.
  • Corrected an issue during system booting from pinned cache, firmware goes to loop message BootMsgDcmd
  • Fixed an issue where a BGI was aborted and restarted, elapsed time was not reset.
  • Fixed an issue where the start ref for a shared cache line was not an indicator of the offset into the stripe.
  • Fixed an issue where the firmware hangs while running CC on a rebuilt R1 VD with SBBM.
  • Fixed an issue where the firmware was wrongly adding puncture entries.
  • Fixed an issue where rebuild was ran twice on a target drive with 100% full SBBM table.
  • Fixed an issue where the firmware was generating powersave change event when DS3 was not enabled, due to this application are not parsing the event.
  • Fixed an issue where recon from R0 to R1 using 3 TB drive causes firmware to report excessive unexpected sense events.
  • Fixed an issue, in which the bbuMode would revert to the factory default value of 5, when automatic learn cycle was enabled.
  • Fixed an issue where cache offload firmware reports unnecessary High Temp Event due to incorrect temp value.
  • Fixed an issue in which a Patrol Read may not start under certain conditions.
  • Fixed an issue where the firmware hits montask after discarding the cache when a snapshot VD was involved.
  • Fixed an issue where the firmware hangs during pin cache destage as dirty lines in that map never become zero.
  • Fixed an issue where CC fails to correct media error at 2TB location on 2 3TB SATA drives that support WU.
  • Fixed an issue where a new XML file was added to the nvdata, the buffer to hold the uncompressed nvdata overflowed.
  • Fixed an issue where an imported drive becomes unconfigured good when secure VD erase was running.
  • Fixed an issue where CC stops progressing on a R6 VD with media errors.
  • Fixed an issue where 3TB Hitachi HDD failed in immunity test (Electrostatic Noise test).
  • Fixed an issue where controller features are lost if RAID Key was not detected
  • Fixed an issue where performance degraded in RAID 5 Sequential Writes due to command Out-of Ordering.
  • Fixed an issue where "Native configuration is no longer supported" message in post.
  • Fixed an issue where (DDR3) Initialization fails with fault 0x91a1 - initial DFIRL selected too low.
  • Fixed an issue where subsequent drives are dropped when all drives in the stagger spin up drives fails on boot sequence.

Off

Document Location

Worldwide

Operating System

System x:VMware vSphere 5.0 x64

System x:VMware ESX Server 4

System x:VMware ESX Server 3

System x:SUSE Linux Enterprise Server 11 x86-64

System x:SUSE Linux Enterprise Server 11

System x:Red Hat Enterprise Linux 5 x86-64

System x:Red Hat Enterprise Linux 5

[{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QU01DEW","label":"System x-\u003ESystem x3500 M4-\u003E7383"},"Platform":[{"code":"PF042","label":"Caldera"},{"code":"PF047","label":"SurePOS"},{"code":"PF032","label":"VM"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QU01DKP","label":"System x-\u003ESystem x3650 M4-\u003E7915"},"Platform":[{"code":"PF042","label":"Caldera"},{"code":"PF047","label":"SurePOS"},{"code":"PF032","label":"VM"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QU01GCQ","label":"System x-\u003ESystem x3530 M4-\u003E7160"},"Platform":[{"code":"PF042","label":"Caldera"},{"code":"PF047","label":"SurePOS"},{"code":"PF032","label":"VM"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QU90ADC","label":"System x-\u003ESystem x iDataPlex dx360 M4 server-\u003E7912"},"Platform":[{"code":"PF042","label":"Caldera"},{"code":"PF047","label":"SurePOS"},{"code":"PF032","label":"VM"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QU90ADI","label":"System x-\u003ESystem x iDataPlex dx360 M4 server-\u003E7913"},"Platform":[{"code":"PF042","label":"Caldera"},{"code":"PF047","label":"SurePOS"},{"code":"PF032","label":"VM"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QU91IPI","label":"System x-\u003ESystem x3550 M4-\u003E7914"},"Platform":[{"code":"PF042","label":"Caldera"},{"code":"PF047","label":"SurePOS"},{"code":"PF032","label":"VM"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QU91LBC","label":"System x-\u003ESystem x iDataPlex dx360 M4 2U chassis-\u003E7913"},"Platform":[{"code":"PF042","label":"Caldera"},{"code":"PF047","label":"SurePOS"},{"code":"PF032","label":"VM"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QU91NCW","label":"System x-\u003ESystem x3630 M4-\u003E7158"},"Platform":[{"code":"PF042","label":"Caldera"},{"code":"PF047","label":"SurePOS"},{"code":"PF032","label":"VM"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QU91SVT","label":"System x-\u003ESystem x3300 M4-\u003E7382"},"Platform":[{"code":"PF042","label":"Caldera"},{"code":"PF047","label":"SurePOS"},{"code":"PF032","label":"VM"}],"Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
28 June 2022

UID

ibm1MIGR-5095422