Download
Version
23.7.0-0029
Release Date
29 May 2014
Downloadable File
| File link | File size | File description |
|---|---|---|
| 5,568,775 | ServeRAID M5100 Series SAS/SATA Controller Firmware Update | |
| 4,827 | CHANGE HISTORY for the ServeRAID M5100 Series SAS/SATA Controller Firmware Update | |
| 5,100 | Readme file for the ServeRAID M5100 Series SAS/SATA Controller Firmware Update | |
| 15,034 | XML for the ServeRAID M5100 Series SAS/SATA Controller Firmware Update |
Abstract
Download the latest ServeRAID M5100 Series SAS/SATA Controller Firmware Update
Download Description
Change history
ServeRAID M5100 Series SAS/SATA Controller Firmware Update for Linux
Adapters Supported
- ServeRAID M5110 SAS/SATA Controller for IBM System x (81Y4481)
- ServeRAID M5110e SAS/SATA Controller for IBM System x
- ServeRAID M5120 SAS/SATA Controller for IBM System x (81Y4478)
Severity Suggested
Version 23.7.0-0029
Enhancements
- Added support for Cache Cade 2.1
- Added Support for PI Drives
Fixes
- Fixed an issue where the firmware reports device initialization completion status to be greater than 100% at startup.
- Fix an issue where when a secure foreign drive was present, VD creation fails because firmware becomes unresponsive
- Added a check for the presence of PD before writing the data arms of a protected LD during BGI.
- Fixed Firmware asserts in CacheMemAllocForPrebootApps() when memory was allocated twice by BIOS.
- Fixed an issue with USB Cacheoffload restore fails after multiple power cycles on ServeRAID M51xx controllers.
- Fixed an issue where querying SMART / PFA Status returns "all zeros" in Sense Data.
- Fixed an issue where the import of a config from MR to iMR resulted in a firmware crash.
- Fixed an issue where iMR firmware crashed while creating 8/16/32 KB stripe size Lds.
- Fixed background initialization watermark conversion to PD LBA.
- Fixed write protected R1E data arms during initialization.
- Fixed an issue where MR firmware crashed while discarding pinned cache.
- Fixed an issue where a dirty LD dependency information of SSD pd has stale entries.
- Corrected an issue during system booting from pinned cache, firmware goes to loop message BootMsgDcmd
- Fixed an issue where a BGI was aborted and restarted, elapsed time was not reset.
- Fixed an issue where the start ref for a shared cache line was not an indicator of the offset into the stripe.
- Fixed an issue where the firmware hangs while running CC on a rebuilt R1 VD with SBBM.
- Fixed an issue where the firmware was wrongly adding puncture entries.
- Fixed an issue where rebuild was ran twice on a target drive with 100% full SBBM table.
- Fixed an issue where the firmware was generating powersave change event when DS3 was not enabled, due to this application are not parsing the event.
- Fixed an issue where recon from R0 to R1 using 3 TB drive causes firmware to report excessive unexpected sense events.
- Fixed an issue, in which the bbuMode would revert to the factory default value of 5, when automatic learn cycle was enabled.
- Fixed an issue where cache offload firmware reports unnecessary High Temp Event due to incorrect temp value.
- Fixed an issue in which a Patrol Read may not start under certain conditions.
- Fixed an issue where the firmware hits montask after discarding the cache when a snapshot VD was involved.
- Fixed an issue where the firmware hangs during pin cache destage as dirty lines in that map never become zero.
- Fixed an issue where CC fails to correct media error at 2TB location on 2 3TB SATA drives that support WU.
- Fixed an issue where a new XML file was added to the nvdata, the buffer to hold the uncompressed nvdata overflowed.
- Fixed an issue where an imported drive becomes unconfigured good when secure VD erase was running.
- Fixed an issue where CC stops progressing on a R6 VD with media errors.
- Fixed an issue where 3TB Hitachi HDD failed in immunity test (Electrostatic Noise test).
- Fixed an issue where controller features are lost if RAID Key was not detected
- Fixed an issue where performance degraded in RAID 5 Sequential Writes due to command Out-of Ordering.
- Fixed an issue where "Native configuration is no longer supported" message in post.
- Fixed an issue where (DDR3) Initialization fails with fault 0x91a1 - initial DFIRL selected too low.
- Fixed an issue where subsequent drives are dropped when all drives in the stagger spin up drives fails on boot sequence.
Off
Document Location
Worldwide
[{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QU01DEW","label":"System x-\u003ESystem x3500 M4-\u003E7383"},"Platform":[{"code":"PF042","label":"Caldera"},{"code":"PF047","label":"SurePOS"},{"code":"PF032","label":"VM"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QU01DKP","label":"System x-\u003ESystem x3650 M4-\u003E7915"},"Platform":[{"code":"PF042","label":"Caldera"},{"code":"PF047","label":"SurePOS"},{"code":"PF032","label":"VM"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QU01GCQ","label":"System x-\u003ESystem x3530 M4-\u003E7160"},"Platform":[{"code":"PF042","label":"Caldera"},{"code":"PF047","label":"SurePOS"},{"code":"PF032","label":"VM"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QU90ADC","label":"System x-\u003ESystem x iDataPlex dx360 M4 server-\u003E7912"},"Platform":[{"code":"PF042","label":"Caldera"},{"code":"PF047","label":"SurePOS"},{"code":"PF032","label":"VM"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QU90ADI","label":"System x-\u003ESystem x iDataPlex dx360 M4 server-\u003E7913"},"Platform":[{"code":"PF042","label":"Caldera"},{"code":"PF047","label":"SurePOS"},{"code":"PF032","label":"VM"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QU91IPI","label":"System x-\u003ESystem x3550 M4-\u003E7914"},"Platform":[{"code":"PF042","label":"Caldera"},{"code":"PF047","label":"SurePOS"},{"code":"PF032","label":"VM"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QU91LBC","label":"System x-\u003ESystem x iDataPlex dx360 M4 2U chassis-\u003E7913"},"Platform":[{"code":"PF042","label":"Caldera"},{"code":"PF047","label":"SurePOS"},{"code":"PF032","label":"VM"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QU91NCW","label":"System x-\u003ESystem x3630 M4-\u003E7158"},"Platform":[{"code":"PF042","label":"Caldera"},{"code":"PF047","label":"SurePOS"},{"code":"PF032","label":"VM"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QU91SVT","label":"System x-\u003ESystem x3300 M4-\u003E7382"},"Platform":[{"code":"PF042","label":"Caldera"},{"code":"PF047","label":"SurePOS"},{"code":"PF032","label":"VM"}],"Line of Business":{"code":"","label":""}}]