IBM Support

ServeRAID M5110e SAS/SATA controller firmware update for BOMC - IBM System x3750 M4

Download


Version

23.12.0-0011

Release Date

15 May 2014

Downloadable File

File link File size File description
6,265,553 ServeRAID M5110e SAS/SATA Controller Firmware Update for BOMC
8,595 CHANGE HISTORY for the ServeRAID M5110e SAS/SATA Controller Firmware Update for BOMC
4,216 Readme file for the ServeRAID M5110e SAS/SATA Controller Firmware Update for BOMC
11,454 XML for the ServeRAID M5110e SAS/SATA Controller Firmware Update for BOMC

Abstract

Download the latest ServeRAID M5110e SAS/SATA Controller Firmware Update for BOMC

Download Description

Change history

ServeRAID M5110e Series SAS/SATA Controller Firmware Update for Linux

Adapters Supported:

ServeRAID M5110e SAS/SATA Controller for IBM System x3750 M4

Version 23.12.0-0011

Enhancement:

  • Implemented Limited Band Charging for iBBU09 (RETAIN tip H21631)
  • Changed BIOS check to determine if running in HAMR, in order to ensure nothing gets broken when user has an iButton which is not programmed.
  • Changed controller status for safe mode to show controller status as safe mode and disable debug message logging in serial port.

Fix:

  • Addressed an issue where deeply discharged Cache Vault Power Modules would be prematurely be marked as failed.
  • Fixed an issue where HII hangs when trying to enter configuration management while in safe mode. Changed the safe mode warning message as below:
    • "Controller is running in safe mode. Safe mode is used for diagnostic purposes only. Limited operations such as Configuration Preview, Clear Configuration and View/Change Controller Properties are allowed in this mode. Other operations such as Create Configuration, Import and Clear Foreign Configurations are not allowed. To exit safe mode, correct the fault, and reboot your computer."
  • Fixed an issue where having more than three adapters results in a calculation error for the offset to store physical disk info for fourth adapter, due to BIOS not clearing upper byte of AX (that is AH which is containing some non zero value).
  • Fixed an issue where the Wrong spanned drive group size is displayed by WebBIOS (Ctrl-H).

Off

Document Location

Worldwide

Operating System

System x:Windows Server 2012

System x:VMware vSphere 5.0 x64

System x:Red Hat Enterprise Linux 6 x86-64

System x:Red Hat Enterprise Linux 6

System x:VMware ESX Server 4

System x:SUSE Linux Enterprise Server 11 x86-64

System x:SUSE Linux Enterprise Server 11

System x:SUSE Linux Enterprise Server 10 x86-64

System x:SUSE Linux Enterprise Server 10

System x:Red Hat Enterprise Linux 5 x86-64

System x:Red Hat Enterprise Linux 5

System x:Windows Server 2008 x86-64 & 2008 R2

System x:Windows Server 2008

[{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QU01GBW","label":"System x-\u003ESystem x3750 M4-\u003E8733"},"Platform":[{"code":"PF042","label":"Caldera"},{"code":"PF047","label":"SurePOS"},{"code":"PF032","label":"VM"},{"code":"PF033","label":"Windows"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QU91NAJ","label":"System x-\u003ESystem x3750 M4-\u003E8722"},"Platform":[{"code":"PF042","label":"Caldera"},{"code":"PF047","label":"SurePOS"},{"code":"PF032","label":"VM"},{"code":"PF033","label":"Windows"}],"Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
08 July 2022

UID

ibm1MIGR-5095325