IBM Support

SAS RAID Module Firmware update v1.3.0.008 Package (for DSM_SFF only) - IBM BladeCenter s

Download


Version

1.3.0.008

Release Date

20 June 2013

Downloadable File

File link File size File description
8,671 XML for the IBM BladeCenter S SAS RAID Module Firmware Update Package (for DSM_SFF only)
14,359 README for the IBM BladeCenter S SAS RAID Module Firmware Update Package (for DSM_SFF only)
55,391 CHANGE HISTORY for the IBM BladeCenter S SAS RAID Module Firmware Update Package (for DSM_SFF only)
54,232,407 IBM BladeCenter S SAS RAID Module Firmware Update Package (for DSM_SFF only)

Abstract

Download the latest SAS RAID Module Firmware update v1.3.0.008 Package (for DSM_SFF only) - IBM BladeCenter s

Download Description

Change history

Version 1.3.0.008 (H3006), Build ID: SR0C130008 (R3.0-GA)

Note:

  • This version currently ONLY supports DSM_SFF enclosure (DSM-12). DSM_LFF (DSM-6) is NOT supported in this release.
  • Users NEED to update to this version or above before installing DSM_SFF enclosure. (by Windows or Linux) Firmware update through SCM is NOT supported.
  • DSM_LFF(DSM-6) configuration SHOULD NOT update to this release.

Enhancements:

  • RHEL 5.9 and 6.4 Support
  • New 3.5-inch SAS hard drivefirmware levels: A3C4, BC4A, J3K7
  • DSM_SFF Enclosure Support
  • 2.5-inch SAS hard driveSupport

Key Fixes

  • 71290: Spinoff CQ61595: Golden area should not be overwritten during firmwareupgrade
  • 61595: Handling userconfig.ini parameter change when perform reset to factory default
  • 71014: Fixed unexpected assert happended when removing DSM during pool rebuild
  • 71294: Fixed unexpected assert happended when removing DDM during pool rebuild
  • 59775: All write commands with the FUA bit set will always use write cache
  • 65488: Fixed wrong timestamp in inactive alert log
  • 60407: Prevent FW upgrade stuck in the FW_UPGRADE_FAILED_FILEMNTERROR status
  • 64858: Additional fix to above issue
  • 56865: Fixed hex drive slot numbers show in alert list
  • 66440: Prevent receiving blank Sender information by using email alert
  • 68321: Fixed continuous reboot after shutdown to service mode
  • 63495: Fixed controller assert after bad drive insertion
  • 67817: Field issues fixed
  • 69002: Fixed duplicate tray number in list drive display after swapping the drives
  • 62062: Fixed RSSM Performance issue with 1.2.3.006 & Volume writecachepolicy
  • 68660: Eliminate extra blank Space in list drive output
  • 68876: Fixed Instruction Break Interrupt from CDC
  • 68971: Prevent Non-Owner controller was trying to discard the dirty cache

Contents:

  • Software Version: H3006
  • BBU: 58.00
  • BBU Utilities: 2009-10-01
  • BMC: S0BT10A
  • PPC FPGA: 01.07
  • Disk Storage Module: 7.26
  • SAS Switch: R1.07
  • SES: 01.07
  • UBoot: H-1.1.4.6
  • 3.5-inch hard drive 73 GB Option part number 43W7523; Replacement part number (FRU) 43W7525
    • MP 41Y8440; FAM MBA3073RC [SA0A]
    • MP 41Y8420; FAM VPBA073C3ETS11 [A496]
    • MP 41Y8400; FAM ST373455SS [BA2D]
  • 3.5-inch hard drive 146 GB Option part number 43W7524; Replacement part number (FRU) 43W7526
    • MP 41Y8441; FAM MBA3147RC [SA0A]
    • MP 41Y8421; FAM VPBA146C3ETS11 [A496]
    • MP 41Y8452; FAM ST3146356SS [BA4D]
    • MP 41Y8401; FAM ST3146855SS [BA2D]
  • 3.5-inch hard drive 300 GB Option part number 43X0802; Replacement part number (FRU) 43X0805
    • MP 41Y8442; FAM MBA3300RC [SA0A]
    • MP 41Y8447; FAM VPBPA300C3EST1 [A529-300]
    • MP 41Y8422; FAM VPBA300C3ETS11 [A496]
    • MP 41Y8453; FAM ST3300656SS [BA4D]
    • MP 41Y8402; FAM ST3300655SS [BA2D]
  • 3.5-inch hard drive 300 GB Option part number 44W2234; Replacement part number (FRU) 44W2235
    • MP 41Y8494; FAM VPCA300900EST1 [A3C4]
    • MP 41Y8484; FAM ST3300657SS [BA5A]
    • MP 41Y8485; FAM ST3300657SS [BA5A]
  • 3.5-inch hard drive 450 GB Option part number 42D0519; Replacement part number (FRU) 42D0520
    • MP 41Y8454; FAM ST3450856SS [BA4D]
  • 3.5-inch hard drive 450 GB Option part number 44W2239; Replacement part number (FRU) 44W2240
    • MP 41Y8495; FAM VPCA450900EST1 [A3C4]
    • MP 41Y8485; FAM ST3450857SS [BA5A]
  • 3.5-inch hard drive 600 GB Option part number 44W2244; Replacement part number (FRU) 44W2245
    • MP 41Y8496; FAM VPCA600900EST1 [A3C4]
    • MP 41Y8486; FAM ST3600057SS [BA5A]
  • 3.5-inch hard drive 750 GB Option part number 42D0546; Replacement part number (FRU) 42D0548
    • MP 41Y8468; FAM ST3750630SS [BC1I]
    • MP 41Y8470; FAM ST3750424SS [BC2D]
    • MP 49Y7462; FAM ST750NM0001 [BC4A]
  • 3.5-inch hard drive 1 TB Option part number 42D0547; Replacement part number (FRU) 42D0559
    • MP 41Y8469; FAM ST31000640SS [BC1I]
  • 3.5-inch hard drive 1 TB Option part number 42D0777; Replacement part number (FRU) 42D0779
    • MP 41Y8470; FAM ST31000424SS [BC2D]
    • MP 49Y7462; FAM ST1000NM0001 [BC4A]
  • 3.5-inch hard drive 2 TB Option part number 42D0767; Replacement part number (FRU) 42D0768
    • MP 41Y8471; FAM ST32000444SS [BC2D]
    • MP 49Y7463; FAM ST2000NM0001 [BC49]
    • MP 49Y7465; FAM HUS723020ALS64 [J3K7]
  • 2.5-inch hard drive 300 GB Option part number 90Y8877; Replacement part number (FRU) 90Y8878
    • MP 00D5300; FAM ST300MM0006 [B56E]
    • MP 00D5309; FAM WD3001BKHG-23D [ZA32]
    • MP 49Y7408; FAM MBF2300RC [SB2C]
    • MP 49Y7414; FAM HUC106030CSS60 [D3A6]
    • MP 49Y7424; FAM ST9300605SS [B55D]
    • MP 49Y7446; FAM HUC109030CSS60 [J2E9]
    • MP 49Y7454; FAM AL13SEB300 [SB31]
  • 2.5-inch hard drive 600 GB Option part number 90Y8872; Replacement part number (FRU) 90Y8873
    • MP 00D5302; FAM ST600MM0006 [B56E]
    • MP 00D5310; FAM WD6001BKHG-23D [ZA32]
    • MP 49Y7410; FAM MBF2600RC [SB2C]
    • MP 49Y7416; FAM HUC106060CSS60 [D3A6]
    • MP 49Y7426; FAM ST9600205SS [B55D]
    • MP 49Y7448; FAM HUC109060CSS60 [J2E9]
    • MP 49Y7456; FAM AL13SEB600 [SB31]
  • 2.5-inch hard drive 900 GB Option part number 81Y9650; Replacement part number (FRU) 81Y9651
    • MP 00D5303; FAM ST900MM0006 [B56E]
    • MP 00D5311; FAM WD9001BKHG-23D [ZA32]
    • MP 49Y7427; FAM ST9900805SS [B55D]
    • MP 49Y7449; FAM HUC109090CSS60 [J2E9]
    • MP 49Y7457; FAM AL13SEB900 [SB31]
  • 2.5-inch hard drive 300 GB Option part number 81Y9670; Replacement part number (FRU) 81Y9671
    • MP 49Y7433; FAM ST9300653SS [B63C]
    • MP 49Y7443; FAM MK3001GRRB [SC29]

Off

Document Location

Worldwide

Operating System

BladeCenter:Red Hat Enterprise Linux 5

BladeCenter:SUSE Linux Enterprise Server 11

BladeCenter:Red Hat Enterprise Linux 6

[{"Type":"HW","Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"HW22P","label":"BladeCenter S Chassis"},"Platform":[{"code":"PF042","label":"Caldera"},{"code":"PF047","label":"SurePOS"}],"Line of Business":{"code":"LOB57","label":"Power"}},{"Type":"HW","Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"HW22P","label":"BladeCenter S Chassis"},"Platform":[{"code":"PF042","label":"Caldera"},{"code":"PF047","label":"SurePOS"}],"Line of Business":{"code":"LOB57","label":"Power"}}]

Document Information

Modified date:
13 April 2023

UID

ibm1MIGR-5093180