Download
Version
1.20
Release Date
11 November 2009
Downloadable File
| File link | File size | File description |
|---|---|---|
| 4,369 | CHANGE HISTORY for (BOFM enabled) BMC firmware update for Windows | |
| 7,731 | README for (BOFM enabled) BMC firmware update for Windows | |
| 8,689 | XML file for (BOFM enabled) BMC firmware update for Windows | |
| 1,401,306 | (BOFM enabled) BMC firmware update for Windows |
Abstract
Download the latest Baseboard Management Controller (BMC) update (Microsoft Windows package) for the IBM BladeCenter HS21 (Type 8853, 1885)
Download Description
Severity: Suggested
Required: Make sure the blade is powered off and all blades are discovered before flashing.
Version 1.20 - Build ID: BCBT60AUS - Suggested
Fixes:
- Corrected the firmware error log length in WHEA data
- Corrected the WHEA firmware logging to not log the de-assertion events
- Fixed the problem that the 4-port 1Gb Ethernet expansion card is shown as unsupported PCI device sometimes on reboots
Enhancements:
- Added support of the revised version of Netezza BIE sidecar
Version 1.19 - Build ID: BCBT59AUS - Suggested
Fixes:
- Fixed the BSE3 events not being logged problem
- Corrected the "Sensor Type" property of sensor AgvPwrIns
- Fixed the problem that blades do not recover from Voltage Fault
- Corrected the Linux update files's name extension in Readme
Enhancements:
- Added support of the Netezza BIE sidecar
Version 1.18 - Build ID: BCBT58AUS
Fixes:
- Fixed the problem that Xeon 5400 series processors erroneously throttle
Version 1.17 - Build ID: BCBT57AUS
Fixes:
- Fixed the problem that HS21 Blades occasionally do not respond to Power Off commands
- Fixed the LED ID's for expansion board LEDs
- Fixed the problem that AMM shows throttle and recovery of blade when power supply 1 and 3 only are installed
- Fixed the incorrect LED colors displayed on LED page of AMM with old version of firmware
- Enable the sensor test function
- Fixed the problem that sometimes system will hang during POST
- Fixed the problem that AMM will show warning of "Problem communicating with BSMP" after reinstall the blade or reset BMC
- Fixed the problem that AMM will show multiple BMC reset message when resetting multiple blades at the same time
Enhancements:
- Added BladeCenter Enterprise Refresh (BCE-R) support update
- Added 8 GB DIMM support
Version 1.16 - Build ID: BCBT53AUS
- Included level 067 of bmc.blade15.v2 and fix fan bump for 50W processor.
Version 1.15 - Build ID: BCBT52AUS
- Fixed QLogic support (440574), fix build problems (441170)
Version 1.14 - Build ID: BCBT51AUS
- Added support for QLogic card (CFFx)
Version 1.13 - Build ID: BCBT50AUS
- Added support for NEMO
- Added RTL support
Version 1.12 - Build ID: BCBT47AUS
- Added improvements in management module to baseboard management controller communications.
- Added support for BPE3
Version 1.11 - Build ID: BCBT42BUS
- Added support for Harpertown Processors
- Increased blower speed for 2GB and 4GB DIMMs
- Fixed a BEM1 Fault with Reboot when BladeCenter Storage Expansion is attached
- Fixed BladeCenter Storage Expansion not reporting defunct drives when attached
See the CHANGE HISTORY file for complete details.