IBM Support

Flash BIOS update - Netfinity 7000

Download


Version

15A

Release Date

27 July 1998

Downloadable File

File link File size File description
2,773 README for the Flash BIOS update
765,179 Flash BIOS update

Abstract

The BIOS Update enhances the Netfinity 7000 to address operational issues, add new functions, or expand functions.

Download Description

Severity: Suggested

Upgrading the BIOS

WARNING: Do not do a BIOS upgrade with the IBM Netfinity 7000 in Remote Console mode. If the server is in Remote Console mode, shut down the remote console and reboot the system.

NOTE
: Please refer to the readme.txt file on the diskette for additional installation instructions.

  1. Be sure you have the correct Flash BIOS update file.
  2. Make sure you have recorded any Setup or SCU changes you may have made before you do the BIOS update.
  3. Place the bootable floppy containing the BIOS into drive A: of the system that you want to upgrade and boot the system while the floppy diskette is in the drive.
  4. The system will boot to a list of options; 1, 2, and 3. Choose 1 to update the system BIOS only. Choose 2 for an interactive version of the BIOS update utility. Choose option 3 to update the system along with the SCSI tables. Option 3 is the recommended option for most customers.
  5. Select Yes to clear the error log when given this option.
  6. Once the BIOS has been successfully loaded, remove the floppy diskette from the drive. The system will automatically reboot when the update has completed.
  7. Check to make sure the BIOS version is the new version as the system reboots and press F1 to enter setup. When in setup press F5 to load defaults. While in setup restore any settings that you made prior to the BIOS update. Save and exit. The system will reboot.
  8. You should run the System Configuration Utility and save your configuration if you had previously used the SCU to set values. Please refer to the IBM Netfinity 7000 User's Handbook for detailed instructions on how to complete this procedure.
  9. When the system boots after the flash update you will see the following message during POST:

    IBM Netfinity 7000
    Model number = ------- Serial number = -------

  10. This is the VPD message. The - indicate that the model and serial number information have not been entered. The instruction below indicates how to add this information. Enter the following command:

    A:\ADDVPD /B:sssssssss /M:8651fff

    In the above command put the 7-digit serial number where the s's are and the 3 digit feature number where the f's are (along with the 8651 model number). The next boot POST will display the VPD banner with the information you enter.

Off

Document Location

Worldwide

Operating System

Older System x:All operating systems listed

[{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HWN01","label":"Older System x->Netfinity 7000"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
04 April 2007

UID

ibm1DDSE-3NGQLK