Diagnostic error codes - IBM eServer xSeries 450

Troubleshooting


Problem

IBM eServer xSeries 450 diagnostic error codes.

Resolving The Problem

Notes:

  1. For information on running the diagnostic programs, see "Starting the AMIDiag program" on page 38 of the Hardware Maintenance Manual.
  2. See IBM eServer xSeries 450 (Type 8688) - System parts listing to determine which components are replaceable by the customer (CRUs), and which components should be replaced by an IBM field service technician (FRUs).
0606h
(Data transfer test failed at port XXXXh1.)

System error codes

Error code/symptom FRU/Action
3000h
(Register Bank Switch Failed.)
  1. Reseat all microprocessors and power modules.
  2. Individually replace microprocessors and power modules.
  3. Processor board
3001h
(Register Read/Write Failed.)
  1. Reseat all microprocessors and power modules.
  2. Individually replace microprocessors and power modules.
  3. Processor board
3002h
(CPU Basic Instruction Operation Failed.)
  1. Reseat all microprocessors and power modules.
  2. Individually replace microprocessors and power modules.
  3. Processor board
3003h
(CPU Parallel Data Manipulation Failed.)
  1. Reseat all microprocessors and power modules.
  2. Individually replace microprocessors and power modules.
  3. Processor board
3005h
(FPU Arithmetic Error)
  1. Reseat all microprocessors and power modules.
  2. Individually replace microprocessors and power modules.
  3. Processor board
3006h
(FPU Comparison Error)
  1. Reseat all processors and power modules.
  2. Individually replace microprocessors and power modules.
  3. Processor board
3007h
(FPU Load/Store Error)
  1. Reseat all microprocessors and power modules.
  2. Individually replace microprocessors and power modules.
  3. Processor board
3008h
(FPU Conversion Error.)
  1. Reseat all microprocessors and power modules.
  2. Individually replace microprocessors and power modules.
  3. Processor board
3010h
(CPU Speed does not match expected value.)
  1. Check that the expected value entered is correct.
  2. Reseat all microprocessors and power modules.
  3. Individually replace microprocessors and power modules.
  4. Processor board
3100h
(Read/Write test on DMA controller 1 failed.)

I/O board

3101h
(Read/Write test on DMA controller 2 failed.)

I/O board

3102h
(Read/Write test on page registers failed.)

I/O board

3140h
(Battery backup unit that powers CMOS RAM has no power.)

Battery or CMOS unit

3141h
(Configuration mismatch in CMOS RAM.)
  1. Run the Configuration/Setup Utility program.
  2. Battery or CMOS unit
3142h
(CMOS RAM memory size.)
  1. Run the Configuration/Setup Utility program.
  2. Battery or CMOS unit
3143h
(CMOS RAM time is invalid.)
  1. Run Configuration/Setup Utility program.
  2. Battery or CMOS unit
3144h
(Bad CMOS RAM checksum detected.)
  1. Run Configuration/Setup Utility program.
  2. Battery or CMOS unit
3145h
(Periodic time update cycle not occurring.)

I/O board

3146h
(CMOS RAM fails to hold data.)

I/O board

00A0h
(PCI Device Enumeration Failed.)
  1. Reseat all PCI devices.
  2. Remove all PCI devices from PCI-X board, and re-run the PCI Test.
  3. If step 2 is successful, replace PCI devices on the PCI-X board one at a time until faulty PCI devices are identified, and replace faulty PCI devices.
  4. PCI-X board
00A1h
(PCI Device Access Failed.)
  1. Reseat all PCI devices.
  2. Remove all PCI devices from PCI-X board, and re-run the PCI Test.
  3. If step 2 is successful, replace PCI devices on the PCI-X board one at a time until faulty PCI devices are identified, and replace faulty PCI devices.
  4. PCI-X board
00A2h
(PCI Configuration Space could not be verified.)
  1. Reseat all PCI devices.
  2. PCI-X board
1000h
(MP table failed or Load MP driver failed.)
  1. Replace SAL/EFI.
  2. I/O board
1009h
(Cache coherency test failed.)
  1. Reseat all microprocessors and power modules.
  2. Individually replace processors and power modules.
  3. Processor board
100Ah
(Memory consistency test failed.)
  1. Reseat all processors and power modules.
  2. Individually replace microprocessors and power modules.
  3. Processor board
100Bh
(I/O access test failed on processor X at port XXXXh.)
  1. Reseat all microprocessors and power modules.
  2. Individually replace microprocessors and power modules.
  3. Processor board
100Eh
(CPU speed error)
  1. Check that the expected value entered is correct.
  2. Reseat all microprocessors and power modules.
  3. Individually replace microprocessors and power modules.
  4. Processor board
1020h
(CPU functionality test failed.)
  1. Reseat all microprocessors and power modules.
  2. Individually replace microprocessors and power modules.
  3. Processor board
1021h
(FPU functionality test failed.)
  1. Reseat all microprocessors and power modules.
  2. Individually replace microprocessors and power modules.
  3. Processor board
1024h
(MP test time out.)
  1. Reseat all microprocessors and power modules.
  2. Individually replace microprocessors and power modules.
  3. Processor board
IDE CD test error codes
Error code/explanation FRU/Action
0A01h
(Eject fails on drive x.)
  1. Manually eject media.
  2. Retry tray function.
  3. Check drive cables and connections.
  4. Drive
  5. I/O board
0A02h
(Close failed on drive x.)
  1. Manually close Drive
  2. Retry tray function.
  3. Check drive cables and connections.
  4. Drive
  5. I/O board
0A03h
(Sequential data test failed, Drive x, Sector Y.)
  1. Replace media.
  2. Check drive cables and connections.
  3. Connect drive to other IDE channel.
  4. Drive
  5. I/O board
0A04h
(Sequential data test failed, No data CD in Drive x.)
  1. Replace media.
  2. Check drive cables and connections.
  3. Connect drive to other IDE channel.
  4. Drive
  5. I/O board
0A05h
(Random data test failed, Drive x, Sector Y.)
  1. Replace media.
  2. Check drive cables and connections.
  3. Connect drive to other IDE channel.
  4. Drive
  5. I/O board
0A06h
(Random data test failed, No data CD in Drive x.)
  1. Replace media.
  2. Check drive cables and connections.
  3. Connect drive to other IDE channel.
  4. Drive
  5. I/O board
0A07h
(Sequential Play test failed, Drive x, Sector y.)
  1. Replace media.
  2. Check drive cables and connections.
  3. Connect drive to other IDE channel.
  4. Drive
  5. I/O board
0A08h
(Sequential Play test failed, no Audio CD in Drive x.)
  1. Replace media.
  2. Check drive cables and connections.
  3. Connect drive to other IDE channel.
  4. Drive
  5. I/O board
0A09h
(Random Play test failed, Drive x, Sector y.)
  1. Replace media.
  2. Check drive cables and connections.
  3. Connect drive to other IDE channel.
  4. Drive
  5. I/O board
0A10h
(Random Play test failed, no Audio CD in Drive x.)
  1. Replace media.
  2. Check drive cables and connections.
  3. Connect drive to other IDE channel.
  4. Drive
  5. I/O board
0A11h
(No Audio tracks in the multisession CD in the Drive x.)
  1. Replace media.
  2. Check drive cables and connections.
  3. Connect drive to other IDE channel.
  4. Drive
  5. I/O board
0A12h
(Number of Audio tracks inadequate for the test.)
  1. Replace media.
  2. Check drive cables and connections.
  3. Connect drive to other IDE channel.
  4. Drive
  5. I/O board

ATAPI removables test error codes

Error code/explanation FRU/Action
0F01h
(No ATAPI Removable drives present.)
  1. Check drive cables and connections.
  2. Connect drive to other IDE channel.
  3. Drive
  4. I/O board
0F02h
(Write failed.)
  1. Replace media.
  2. Check drive cables and connections.
  3. Connect drive to other IDE channel.
  4. Drive
  5. I/O board
0F03h
(Read failed.)
  1. Replace media.
  2. Check drive cables and connections.
  3. Connect drive to other IDE channel.
  4. Drive
  5. I/O board
0F04h
(Seek operation failed.)
  1. Replace media.
  2. Check drive cables and connections.
  3. Connect drive to other IDE channel.
  4. Drive
  5. I/O board
0F05h
(Eject fails on drive x.)
  1. Replace media.
  2. Check drive cables and connections.
  3. Connect drive to other IDE channel.
  4. Drive
  5. I/O board
0F06h
(Sequential Read Verify failed.)
  1. Replace media.
  2. Check drive cables and connections.
  3. Connect drive to other IDE channel.
  4. Drive
  5. I/O board
0F07h
(Random Read Operation failed.)
  1. Replace media.
  2. Check drive cables and connections.
  3. Connect drive to other IDE channel.
  4. Drive
  5. I/O board
0F08h
(Random Read Verify failed.)
  1. Replace media.
  2. Check drive cables and connections.
  3. Connect drive to other IDE channel.
  4. Drive
  5. I/O board
0F09h
(Random Seek Operation failed.)
  1. Replace media.
  2. Check drive cables and connections.
  3. Connect drive to other IDE channel.
  4. Drive
  5. I/O board
IDE DVD-ROM drive test error codes
Error code/explanation FRU/Action
1900h
(Critical/Command Error.)
  1. Replace media.
  2. Check drive cables and connections.
  3. Connect drive to other IDE channel.
  4. Drive
  5. I/O board
1901h
(DVD Seek Test failed.)
  1. Replace media.
  2. Check drive cables and connections.
  3. Connect drive to other IDE channel.
  4. Drive
  5. I/O board
1902h
(DVD Read Test failed.)
  1. 1. Replace media.
  2. 2. Check drive cables and connections.
  3. 3. Connect drive to other IDE channel.
  4. 4. Drive
  5. 5. I/O board
SCSI test error codes
Error code/explanation FRU/Action
0500h
(SCSI device not ready.)
  1. Confirm that drive is configured.
  2. Check drive cables and connections.
  3. Drive
  4. I/O board or SCSI add-on controller
0502h
(SCSI device read error.)
  1. Confirm that drive is configured.
  2. Check drive cables and connections.
  3. Drive
  4. I/O board or SCSI add-on controller
0506h
(SCSI disk self test failed.)
  1. Confirm that drive is configured.
  2. Check drive cables and connections.
  3. Drive
  4. I/O board or SCSI add-on controller
0507h
(SCSI disk buffer error.)
  1. Confirm that drive is configured.
  2. Check drive cables and connections.
  3. Drive
  4. I/O board or SCSI add-on controller
0508h
(SCSI disk random read error.)
  1. Confirm that drive is configured.
  2. Check drive cables and connections.
  3. Drive
  4. System I/O Board or SCSI add-on controller
0509h
(SCSI disk random write error.)
  1. Confirm that drive is configured.
  2. Check drive cables and connections.
  3. Drive
  4. I/O board or SCSI add-on controller
050Ch
(Error in disk partition table.)
  1. Confirm that drive is formatted and configured.
  2. Check drive cables and connections.
  3. Drive
  4. I/O board or SCSI add-on controller
050Dh
(Boot sector error. The boot partition has an incorrect definition.)
  1. Confirm that drive is formatted and configured.
  2. Check drive cables and connections.
  3. Drive
  4. I/O board or SCSI add-on controller
050Eh
(Media error. The media description for the partition is bad. The unit is not properly formatted.)
  1. Confirm that drive is formatted and configured.
  2. Check drive cables and connections.
  3. Drive
  4. I/O Board or SCSI add-on controller
050Fh
(The sector number information in the partition table is wrong. The unit is not properly OS formatted.)
  1. Confirm that drive is formatted and configured.
  2. Check drive cables and connections.
  3. Drive
  4. I/O board or SCSI add-on controller
0510h
(No Tape in the Drive)
  1. Check if a tape is in Drive.
  2. Confirm that drive is configured.
  3. Check drive cables and connections.
  4. Drive
  5. I/O board or SCSI add-on controller
0511h
(Positioning failed on tape Drive)
  1. Confirm that drive is configured.
  2. Check drive cables and connections.
  3. Drive
  4. I/O board or SCSI add-on controller
0512h
(Tape read error)
  1. Check if write test has been run.
  2. Confirm that drive is configured.
  3. Check drive cables and connections.
  4. Drive
  5. I/O board or SCSI add-on controller
0515h
(Tape Self-test error)
  1. Confirm that drive is configured.
  2. Check drive cables and connections.
  3. Drive
  4. I/O board or SCSI add-on controller
0516h
(Tape buffer error)
  1. Confirm that drive is configured.
  2. Check drive cables and connections.
  3. Drive
  4. I/O board or SCSI add-on controller
0520h
(No CD in the Drive)
  1. Check if a CD is in Drive.
  2. Confirm that drive is configured.
  3. Check drive cables and connections.
  4. Drive
  5. I/O board or SCSI add-on controller
0521h
(CD-ROM read error)
  1. Confirm that drive is configured.
  2. Checkdrive cablesand connections.
  3. Drive
  4. I/O board or SCSI add-on controller
0523h
(CD-ROM play error)
  1. Confirm that drive is configured.
  2. Check drive cables and connections.
  3. Drive
  4. I/O board or SCSI add-on controller
0524h
(CD Self-test error)
  1. Confirm that drive is configured.
  2. Check drive cables and connections.
  3. Drive
  4. I/O board or SCSI add-on controller
0525h
(CD Open error)
  1. Manually eject media and close Drive.
  2. Retry tray function.
  3. Confirm that drive is configured.
  4. Check drive cables and connections.
  5. Drive
  6. I/O board or SCSI add-on controller
0526h
(CD Close error)
  1. Manually eject media and close Drive.
  2. Retry tray function.
  3. Confirm that drive is configured.
  4. Check drive cables and connections.
  5. Drive
  6. I/O board or SCSI add-on controller
0527h
(CD Buffer error)
  1. Confirm that drive is configured.
  2. Check drive cables and connections.
  3. Drive
  4. I/O board or SCSI add-on controller
0528h
(Pattern compare failed. Check pattern did not match.)
  1. Check if AMIDiag CD is present in Drive.
  2. Confirm that drive is configured.
  3. Check drive cables and connections.
  4. Drive
  5. I/O board or SCSI add-on controller
0529h
(CD-ROM random read error.)
  1. Confirm that drive is configured.
  2. Check drive cables and connections.
  3. Drive
  4. I/O board or SCSI add-on controller
0550h
(Read timeout.)
  1. Confirm that drive is configured.
  2. Check drive cables and connections.
  3. Drive
  4. I/O board or SCSI add-on controller
0560h
(File not found.)
  1. Check if AMIDiag CD is present in Drive
  2. Confirm that drive is configured.
  3. Check drive cables and connections.
  4. Drive
  5. I/O board or SCSI add-on controller
0580h
(Cannot allocate memory.)
Restart the server and retry.
0590h
(Command not supported. Unable to run the test on the device.)
  1. Confirm that drive is configured.
  2. Check drive cables and connections.
  3. Drive
  4. I/O board or SCSI add-on controller
Video test error codes
Error code/explanation FRU/Action
0900h
(Vertical Synchronization Test failed.)

I/O board

0901h
(Horizontal Synchronization Test failed.)

I/O board

0902h
(Graphics controller test failed.)

I/O board

0903h
(Attribute controller test failed.)

I/O board

0904h
(DAC register test failed.)

I/O board

0905h
(Video adapter memory R/W test failed.)

I/O board

2100h
(Video adapter attribute test failed.)
  1. Video monitor
  2. I/O board
2102h
(Video adapter color test failed.)
  1. Video monitor
  2. I/O board
2110h - 2120h
(Param1 x Param2 mode test failed.)
  1. Video monitor
  2. I/O board
USB test error codes

If any of the following USB errors occur on devices not directly attached to a USB port on the xSeries 450 (for example, a USB mouse attached to a USB keyboard with an internal USB hub), connect the suspect device directly to the xSeries 450 and re-run the failing test to isolate whether the failure is with an intermediate device, the device being tested, or the USB subsystem of the xSeries 450. In cases where the direct attachment passes, replace the intermediate devices and re-test in the original configuration before replacing the device being tested or the I/O board.

Error code/explanation FRU/Action
0B00h
(USB mouse set protocol failed.)
  1. Check USB mouse connection.
  2. USB mouse
  3. I/O board
0B01h
(USB mouse remove and attach tests failed.)
  1. Check USB mouse connection.
  2. USB mouse
  3. I/O board
0B02h
(USB mouse not present.)
  1. Check USB mouse connection.
  2. USB mouse
  3. I/O board
0B30h
(USB keyboard control test failed.)
  1. Check USB keyboard connection.
  2. USB keyboard
  3. I/O board
0B40h
(USB keyboard LED test failed.)
  1. Check USB keyboard connection.
  2. USB keyboard
  3. I/O board
0B50h
(USB keyboard remove and attach test failed.)
  1. Check USB keyboard connection.
  2. USB keyboard
  3. I/O board
0B60h
(USB keyboard not present.)
  1. Check USB keyboard connection.
  2. USB keyboard
  3. I/O board
0B70h
(USB Hub communication test failed.)
  1. Check USB hub connection.
  2. USB hub
  3. I/O board
1302h
(UHCI Register Test failed.)

I/O board

1303h
(UHCI Status Test failed.)

I/O board

1304h
(UHCI Interrupt Test failed.)

I/O board

1305h
(UHCI Frame Test failed.)

I/O board

1306h
(UHCI Transfer Descriptor Test failed.)

I/O board

1312h
(OHCI Register Test failed.)

I/O board

1313h
(OHCI Status Test failed.)

I/O board

1314h
(OHCI Interrupt Test failed.)

I/O board

1315h
(OHCI Frame Test failed.)

I/O board

1316h
(OHCI Transfer Descriptor Test failed.)

I/O board

Serial port test error codes
Error code/explanation FRU/Action
0601h
(Data written to port XXXXh was yyyyh. Data read back from the port was zzzzh.)
  1. Check connection of loopback if used during test.
  2. I/O board
0602h
(Interrupt identification register test failed.)

I/O board

0603h
(Data written to port XXXXh was yyyyh. Data read back from the port was zzzzh.)
  1. Check connection of loopback if used during test.
  2. I/O board
0604h
(Line status register test failed at port XXXXh.)

I/O board

0605h
(Interrupt activation test failed at port XXXXh.)

I/O board

  1. Check connection of loopback if used during test.
  2. I/O board
0607h
(Loop back test failed at port XXXXh.)
  1. Check connection of loopback if used during test.
  2. I/O board
0608h
(FIFO register test failed at port XXXXh.)

I/O board

0609h
(FIFO trigger level test failed at port XXXXh.)

I/O board

0610h
(FIFO character timeout indication test failed at port XXXXh.)

I/O board

0611h
(FIFO data transfer test failed at port XXXXh.)

I/O board

0612h
(Baud rate speed test failed at port XXXXh.)

I/O board

Advanced System Management error codes
Error code/explanation FRU/Action
9100-xxx-xxx-xxx
(SAL/EFI failed to communicate with ASM.)
  1. Run ASM Restart Test to restart ASM.
  2. Rerun diagnostic test.
  3. Correct other error conditions, including other failed system management tests and items logged in Remote Supervisor adapter system-error log, and retry.
  4. Disconnect all server and option power cords from server, wait 30 seconds, reconnect, and retry.
  5. Remote Supervisor Adapter.
  6. I/O board
9101-000-000-000
(DMC Self Test failed to complete.)
  1. Disconnect all server and option power cords from server, wait 30 seconds, reconnect, and retry.
  2. Update the ISMP on the xSeries 450 node and RXE with the latest firmware level.
  3. RXE backplane if test on RXE unit, I/O board if test on xSeries 450 node.
9102-000-000-000
(DMC Self Test failed update.)
  1. Disconnect all server and option power cords from server, wait 30 seconds, reconnect, and retry.
  2. Update the ISMP on the xSeries 450 node and RXE with the latest firmware level.
  3. RXE backplane if test on RXE unit, I/O board if test on xSeries 450 node.
9103-000-000-000
(DMC Self Test failed ROM.)
  1. Disconnect all server and option power cords from server, wait 30 seconds, reconnect, and retry.
  2. Update the ISMP on the xSeries 450 node and RXE with the latest firmware level.
  3. RXE backplane if test on RXE unit, I/O board if test on xSeries 450 node.
9104-000-000-000
(DMC Self Test failed RAM.)
  1. Disconnect all server and option power cords from server, wait 30 seconds, reconnect, and retry.
  2. Update the ISMP on the xSeries 450 node and RXE with the latest firmware level.
  3. RXE backplane if test on RXE unit, I/O board if test on xSeries 450 node.
9105-004-000-000
(ISMP indicates I2C errors on bus A0.)
  1. I/O board
  2. Midplane board
9105-004-001-000
(ISMP indicates I2C errors on bus A1.)
  1. VRMs and microprocessors installed in midplane board
  2. Midplane board
9105-004-002-000
(ISMP indicates I2C errors on bus A2.)
  1. Memory board
  2. Midplane board
9105-004-003-000
(ISMP indicates I2C errors on bus A3.)
  1. I/O board
  2. Remote Supervisor Adapter
  3. Midplane board
9105-004-004-000
(ISMP indicates I2C errors on bus A4.)
  1. PCI devices on PCI-X card
  2. PCI-X card
  3. Midplane board
9105-004-005-000
(ISMP indicates I2C errors on bus A5.)
  1. Power supply
  2. Top power board
  3. Midplane board
9105-004-006-000
(ISMP indicates I2C errors on bus A6.)

Midplane board

9105-004-007-000
(ISMP indicates I2C errors on bus A7.)
  1. Hard disk drive backplane
  2. SCSI I2C cable
  3. Midplane board
9105-004-008-000
(ISMP indicates I2C errors on bus A8.)
  1. Light Path card
  2. Light Path cable
  3. Midplane board
9105-004-009-000
(ISMP indicates I2C errors on bus A2M0.)
  1. Memory DIMMs 1-7
  2. Memory board
9105-004-00a-000
(ISMP indicates I2C errors on bus A2M1.)
  1. Memory DIMMs 8-14
  2. Memory board
9105-004-00b-000
(ISMP indicates I2C errors on bus A2M2.)
  1. Memory DIMMs 15-21
  2. Memory board
9105-004-00c-000
(ISMP indicates I2C errors on bus A2M3.)
  1. Memory DIMMs 22-28
  2. Memory board
9105-004-00d-000
(ISMP indicates errors on bus A4J0.)

PCI-X board

9105-004-00e-000
(ISMP indicates errors on bus A4J1.)

PCI-X board

9105-004-00f-000
(ISMP indicates errors on bus A4J2.)

PCI-X board

9105-004-010-000
(ISMP indicates I2C errors on bus A4J3.)

PCI-X board

9105-004-011-000
(ISMP indicates I2C errors on bus A4J1 PCI slot 1.)
  1. PCI adapter in PCI-X slot 1
  2. PCI-X board
9105-004-012-000
(ISMP indicates I2C errors on bus A4J1 PCI slot 2.)
  1. PCI adapter in PCI-X slot 2
  2. PCI-X board
9105-004-013-000
(ISMP indicates I2C errors on bus A4J1 PCI slot 3.)
  1. PCI adapter in PCI-X slot 3
  2. PCI-X board
9105-004-014-000
(ISMP indicates I2C errors on bus A4J1 PCI slot 4.)
  1. PCI adapter in PCI-X slot 4
  2. PCI-X board
9105-004-015-000
(ISMP indicates I2C errors on bus A4J1 PCI slot 5.)
  1. PCI adapter in PCI-X slot 5
  2. PCI-X board
9105-004-016-000
(ISMP indicates I2C errors on bus A4J1 PCI slot 6.)
  1. PCI adapter in PCI-X slot 6
  2. PCI-X board
9105-001-000-000 or 9105-002-000-000
(ISMP indicates I2C errors on RXE bus X.)
See the Hardware Maintenance Manual for the RXE-100 Remote Expansion Enclosure.
9105-001-001-000 or 9105-002-001-000
(ISMP indicates I2C errors on RXE bus P.)
See the Hardware Maintenance Manual for the RXE-100 Remote Expansion Enclosure.
9105-001-002-000
(ISMP indicates I2C errors on RXE bus I_A.)
See the Hardware Maintenance Manual for the RXE-100 Remote Expansion Enclosure.
9105-002-003-000
(ISMP indicates I2C errors on RXE bus I_B.)
See the Hardware Maintenance Manual for the RXE-100 Remote Expansion Enclosure.
9105-001-004-000
(ISMP indicates I2C errors on RXE bus PCI_A)
See the Hardware Maintenance Manual for the RXE-100 Remote Expansion Enclosure.
9105-001-005-000 or 9105-002-005-000
(ISMP indicates I2C errors on RXE bus F.)
See the Hardware Maintenance Manual for the RXE-100 Remote Expansion Enclosure.
9105-002-006-000
(ISMP indicates I2C errors on RXE bus PCI_B)
See the Hardware Maintenance Manual for the RXE-100 Remote Expansion Enclosure.
9105-001-007-000
(ISMP indicates I2C errors on RXE bus PCI_A slot 1.)

PCI adapter in slot A1

9105-001-008-000
(ISMP indicates I2C errors on RXE bus PCI_A slot 2.)

PCI adapter in slot A2

9105-001-009-000
(ISMP indicates I2C errors on RXE bus PCI_A slot 3.)

PCI adapter in slot A3

9105-001-00a-000
(ISMP indicates I2C errors on RXE bus PCI_A slot 4.)

PCI adapter in slot A4

9105-001-00b-000
(ISMP indicates I2C errors on RXE bus PCI_A slot 5.)

PCI adapter in slot A5

9105-001-00c-000
(ISMP indicates I2C errors on RXE bus PCI_A slot 6.)

PCI adapter in slot A6

9105-002-00d-000
(ISMP indicates I2C errors on RXE bus PCI_B slot 1.)

PCI adapter in slot B1

9105-001-00e-000
(ISMP indicates I2C errors on RXE bus PCI_B slot 2.)

PCI adapter in slot B2

9105-001-00f-000
(ISMP indicates I2C errors on RXE bus PCI_B slot 3.)

PCI adapter in slot B3

9105-001-010-000
(ISMP indicates I2C errors on RXE bus PCI_B slot 4.)

PCI adapter in slot B4

9105-001-011-000
(ISMP indicates I2C errors on RXE bus PCI_B slot 5.)

PCI adapter in slot B5

9105-001-012-000
(ISMP indicates I2C errors on RXE bus PCI_B slot 6.)

PCI adapter in slot B6

9106-xxx-xxx-xxx
(ISMP indicates untested I2C bus.)
  1. Run diagnostic test again.
  2. Correct other error conditions, including other system-management tests and items logged in Remote Supervisor Adapter system-error log, and retry.
  3. Disconnect all server and option power cords, wait 30 seconds, reconnect, and retry.
  4. Update the xSeries 450 node with the latest firmware level of diagnostics, ISMP, and ASM. Update RXE with latest ISMP firmware, and retry.
  5. If a 9106 error occurs again, follow the FRU/action for error 9105 with respective parameter set.
9107-xxx-000-000
(System Management BIST indicates failed tests.)
  1. Run Restart ASM Test and re-run ASM BIST Test.
  2. Disconnect all server and option power cords from server, wait 30 seconds, reconnect, and retry.
  3. Remote Supervisor Adapter
RXE port error codes
Error code/explanation FRU/Action
9204-091-094-011
(RXE Expansion Port A failure.)
  1. RXE cable A
  2. RXE expansion board to which cable is connected (Side A or Side B)
  3. I/O board
9204-091-094-012
(RXE Expansion Port B failure.)
  1. RXE cable B
  2. RXE expansion board to which cable is connected (Side A or Side B)
  3. Processor board
  4. Midplane board
9204-091-094-015
(RXE100 Side A to Side B failure.)
  1. Side A card in RXE100
  2. Side B card in RXE100
9204-091-094-016
(RXE100 Side B to Side A failure.)
  1. Side B card in RXE100
  2. Side A card in RXE100
9216-091-094-nnn
(Receive Error on any port.)
Restart the server. This usually means that an RXE cable has been attached after SAL/EFI has run.
9220-091-094-011
(Transmit error on Port A.)
  1. RXE cable B
  2. RXE expansion board to which cable is connected (Side A or Side B)
  3. I/O board
9220-091-094-012
(Transmit error on Port B.)
  1. RXE cable B
  2. RXE expansion board to which cable is connected (Side A or Side B)
  3. Processor board
  4. Midplane board
9220-091-094-015
(RXE100 Side A to Side B failure.)
  1. Side A card in RXE100
  2. Side B card in RXE100
9220-091-094-016
(RXE100 Side B to Side A failure.)
  1. Side B card in RXE100
  2. Side A card in RXE100
9228-091-094-011
(No incoming power on Port A.)

Missing cable on Port A

9228-091-094-012
(No incoming power on Port B.)

Missing cable on Port B

9228-091-094-014
(No incoming power on port.)

Missing cable on RXE100 Side A Port A

9228-091-094-017
(No incoming power on port.)

Missing cable on RXE100 Side B Port B

9232-091-094-011
(Driver disabled on Port A.)

Missing cable on Port A

9232-091-094-012
(Driver disabled on Port B.)

Missing cable on Port B

9232-091-094-014
(Driver disabled on port.)

Missing cable on RXE100 Side A Port A

9232-091-094-017
(Driver disabled on port.)

Missing cable on RXE100 Side B Port B

9236-091-094-011
(Port A is disabled.)

Missing cable on Port A

9236-091-094-012
(Port B is disabled.)

Missing cable on Port B

9236-091-094-014
(RXE100 Side A Port A is disabled.)

Missing cable on RXE100 Side A Port A

9236-091-094-017
(RXE100 Side B Port B is disabled.)

Missing cable on RXE100 Side B Port B

Memory test error codes
Error code/explanation FRU/Action
9301-xxx-00-00
(Test Aborted: Memory Hole Size Error.)
  1. Restart the server, and run the test again.
  2. If the symptom still exists, then update the SAL/EFI.
9302-xxx-00-00
(Test Aborted: DIMM Configuration Error.)
  1. Restart the server, and run the test again.
  2. If the symptom still exists, then update the SAL/EFI.
9303-xxx-00-00
(EFI operating system error. Test Aborted: Buffer too small.)
  1. Restart the server, and run the test again.
  2. If the symptom still exists, reload the EFI operating system.
9304-xxx-00-00
(EFI operating system error. Test Aborted: Invalid Parameter.)
  1. Restart the server, and run the test again.
  2. If the symptom still exists, reload the EFI operating system.
9305-xxx-00-00
(Test Aborted: Memory WRT not complete.)
  1. Restart the server, and run the test again.
  2. If the symptom still exists, replace the memory board.
9306-xxx-00-00
(Memory Diagnostic Program Error. Test Aborted: Invalid Bank Selected.)
  1. Restart the server, and run the test again.
  2. If the symptom still exists, reflash the diagnostic code.
9306-xxx-00-00
(Memory Diagnostic Program Error. Test Aborted: Invalid Bank Selected.)
  1. Restart the server, and run the test again.
  2. If the symptom still exists, reflash the diagnostic code.
9308-xxx-00-00
(Diagnostic Program Error. Test Aborted: No DIMMs
  1. Restart the server, and run the test again.
  2. If the symptom still exists, reflash the diagnostic code.
9309-xxx-00-00
(Test Aborted: Fast Scrub Error.)
  1. Reload the system, and run the test again.
  2. If the symptom still exists, replace the memory board.
9310-xxx-nn-nn
(Test Failed: ECC errors.) nn= the DIMM connector designation, 1-28.
  1. Restart the server, and run the test again.
  2. If the symptom still exists, replace the DIMMs.
LED error codes
Error code/explanation FRU/Action
LED error codes
9001-180-xxx-xxx
(Failed Front LED panel test.)
  1. Light Path Diagnostics card
  2. Power/reset card assembly
  3. Midplane board
  4. I/O board
9002-180-xxx-xxx
(Failed Memory Board LED test.)
  1. Memory board
  2. Midplane board
9003-180-xxx-xxx
(Failed Active PCI LED test.)

PCI-X board

9004-180-xxx-xxx
(Failed Diagnostics LED test.)
  1. Light Path Diagnostics card
  2. Midplane board
9005-180-xxx-xxx
(Failed Fan LED test.)
  1. Fan
  2. I/O board
9006-180-xxx-xxx
(Failed Centerplane LED test.)

Midplane board

9007-180-xxx-xxx
(Failed I/O board LED test.)

I/O board

9008-180-xxx-xxx
(Failed SCSI Backplane LED test.)
  1. SCSI backplane cable
  2. SCSIbackplane
  3. Midplane board
LED error codes for the RXE100 port
9021-180-xxx-xxx
(Failed RXE Operator panel LED test)
  1. RXE Operator panel cable
  2. RXE Operator panel
  3. RXE backplane
9022-180-xxx-xxx
(Failed RXE PCIXBackplane Side A LED test)
  1. RXE PCI-X backplane (Side A)
  2. RXE backplane
9023-180-xxx-xxx
(Failed RXE PCIX Backplane Side B LED test)
  1. RXE PCI-X backplane (Side B)
  2. RXE backplane
9024-180-xxx-xxx
(Failed RXE Fans LED test)
  1. RXE fans
  2. RXE backplane
9025-180-xxx-xxx
(Failed RXE backplane LED test)

RXE backplane

Document Location