IBM Support

Diagnostic error codes - Netfinity 5500

Troubleshooting


Problem

Refer to the following Diagnostic Error Codes when using the IBM PC Enhanced Diagnostics test.

Resolving The Problem



Diagnostic Error Codes


Attention
In the following error codes, if XXX is 000, 195, or 197 do not replace a FRU. The description for these error codes are:


000 The test passed.
195 The Esc key was pressed to abort the test.
197 This is a warning error and may not indicate a hardware failure.

For all error codes, replace/follow the FRU/Action indicated.



Error Code/Symptom FRU/Action
001-XXX-001
(Failed core tests)
1. System Board
001-XXX-001
(Failed core tests)
1. Processor Board
001-250-000
(Failed System Board ECC)
1. System Board
001-250-001
(Failed Processor Board ECC)
1. Processor Board
2. System Board
005-XXX-000
(Failed Video test)
1. System Board
2. Processor Board

011-XXX-000
(Failed COM1 Serial Port test)
Note: The external loopback test of Serial Port A will fail if run remotely.
1. System Board
011-XXX-001
(Failed COM2 Serial Port test)
1. System Board
014-XXX-000
(Failed Parallel Port test)
1. System Board
015-XXX-001
(Failed USB test)
1. System Board
020-XXX-000
(Failed PCI Interface test)
1. Processor Board
2. System Board
020-XXX-001
(Failed Hot-Swap Slot 1 PCI Latch test)
1. PCI Hot-Swap Latch Assembly
2. System Board


020-XXX-002
(Failed Hot-Swap Slot 2 PCI Latch test)
1. PCI Hot-Swap Latch Assembly
2. System Board
020-XXX-003
(Failed Hot-Swap Slot 3 PCI Latch test)
1. PCI Hot-Swap Latch Assembly
2. System Board
020-XXX-004
(Failed Hot-Swap Slot 4 PCI Latch test)
1. PCI Hot-Swap Latch Assembly
2. System Board
030-XXX-000
(Failed Internal SCSI interface test)
1. System Board
035-XXX-000
DUPLICATE ERROR CODE
(Failed System Board RAID test. Check System Error Log before replacing a FRU.)
1. Verify RAID adapter disable jumper block is not installed (see System board jumpers .)
2. System Board
3. SCSI Backplane
4. Cable
035-XXX-000
DUPLICATE ERROR CODE
(Check System Error Log before replacing a FRU.)
1. Fixed Disk with SCSI ID 00 on System Board RAID controller
035-XXX-0NN
(Check System Error Log before replacing a FRU.
NN = SCSI ID of failing fixed disk.)
1. Fixed Disk with SCSI ID NN on System Board RAID controller


035-XXX-100
DUPLICATE ERROR CODE
(Failed RAID test on PCI slot 1. Check System Error Log before replacing a FRU.)
1. Adapter
2. SCSI Backplane
3. Cable
035-XXX-100
DUPLICATE ERROR CODE
(Check System Error Log before replacing a FRU.)
1. Fixed Disk with SCSI ID 00 on RAID adapter in PCI slot 1
035-XXX-1NN
(Check System Error Log before replacing a FRU. NN = SCSI ID of failing fixed disk.)
1. Fixed Disk with SCSI ID NN on RAID adapter in PCI slot 1
035-XXX-200
DUPLICATE ERROR CODE
(Failed RAID test on PCI slot 2. Check System Error Log before replacing a FRU.)
1. Adapter
2. SCSI Backplane
3. Cable
035-XXX-200
DUPLICATE ERROR CODE
(Check System Error Log before replacing a FRU.)
1. Fixed Disk with SCSI ID 00 on RAID adapter in PCI slot 2
035-XXX-2NN
(Check System Error Log before replacing a FRU. NN = SCSI ID of failing fixed disk.)
1. Fixed Disk with SCSI ID NN on RAID adapter in PCI slot 2


035-XXX-300
DUPLICATE ERROR CODE
(Failed RAID test on PCI slot 3. Check System Error Log before replacing a FRU.)
1. Adapter
2. SCSI Backplane
3. Cable
035-XXX-300
DUPLICATE ERROR CODE
(Check System Error Log before replacing a FRU.)
1. Fixed Disk with SCSI ID 00 on RAID adapter in PCI slot 3
035-XXX-3NN
(Check System Error Log before replacing a FRU. NN = SCSI ID of failing fixed disk.)
1. Fixed Disk with SCSI ID NN on RAID adapter in PCI slot 3
035-XXX-400
DUPLICATE ERROR CODE
(Failed RAID test on PCI slot 4. Check System Error Log before replacing a FRU.)
1. Adapter
2. SCSI Backplane
3. Cable
035-XXX-400
DUPLICATE ERROR CODE
(Check System Error Log before replacing a FRU.)
1. Fixed Disk with SCSI ID 00 on RAID adapter in PCI slot 4
035-XXX-4NN
(Check System Error Log before replacing a FRU. NN = SCSI ID of failing fixed disk.)
1. Fixed Disk with SCSI ID NN on RAID adapter in PCI slot 4


035-XXX-500
DUPLICATE ERROR CODE
(Failed RAID test on PCI slot 5. Check System Error Log before replacing a FRU.)
1. Adapter
2. SCSI Backplane
3. Cable
035-XXX-500
DUPLICATE ERROR CODE
(Check System Error Log before replacing a FRU.)
1. Fixed Disk with SCSI ID 00 on RAID adapter in PCI slot 5
035-XXX-5NN
(Check System Error Log before replacing a FRU. NN = SCSI ID of failing fixed disk.)
1. Fixed Disk with SCSI ID NN on RAID adapter in PCI slot 5
035-253-N00
(RAID initialization error for adapter in PCI slot number N.)
1. ServeRAID Adapter is not configured correctly. Refer to the ServeRAID Hardware Maintenance Manual for more information.


075-XXX-000
(Failed Power Supply test)
1. Power Supply
089-XXX-001
(Failed Microprocessor test)
1. VRM for Microprocessor
2. Microprocessor
089-XXX-002
(Failed Optional Microprocessor test)
1. VRM for Optional Microprocessor
2. Optional Microprocessor
165-XXX-000
(Failed System Board test)


1. System Board
Before replacing the system board, ensure that system board jumper J51 is not installed (the default) when the error occurs.
2. Processor Board
3. Power Backplane
4. Hot-Swap DriveBackplane


175-XXX-001
(Failed Fan 1 test)
1. Fan 1
175-XXX-002
(Failed Fan 2 test)
1. Fan 2
175-XXX-003
(Failed Fan 2 test)
1. Fan 3
175-XXX-004
(Processor Board Temperature sensor out of range)
1. Check system cooling
180-XXX-000
(Diagnostics LED failure)
1. Run Diagnostic LED test for the failing LED
180-XXX-001
(Failed Information Panel LED test)
1. Information LED Panel
2. Power-on Panel
180-XXX-002
(Failed Diagnostics LED Panel test)
1. Diagnostics LED Panel
2. Power-on Panel
180-XXX-003
(Failed System Board LED test)
1. Run hot-swap PCI latch test in Other Devices under Extended Tests
2. System Board
180-XXX-004
(Failed Processor Board LED test)
1. Processor Board
2. System Board
180-XXX-005
(Failed SCSI Backplane LED test)
1. SCSI Backplane
2. SCSI Backplane Cable
3. System Board


201-XXX-001
(Failed Memory test, see "Memory Settings")
1. DIMM Location J1
201-XXX-002
(Failed Memory test, see "Memory Settings")
1. DIMM Location J2
201-XXX-003
(Failed Memory test, see "Memory Settings")
1. DIMM Location J3
201-XXX-004
(Failed Memory test, see "Memory Settings")
1. DIMM Location J4
201-XXX-999
(Multiple DIMM failure, see error text.)
1. See error text for failing DIMMs
202-XXX-001
(Failed System Cache test)
1. Microprocessor
202-XXX-002
(Failed System Cache test on Optional Microprocessor)
1. Optional Microprocessor
206-XXX-000
(Failed Diskette Drive test)
1. Diskette Drive cable
2. Diskette Drive
3. System Board
215-XXX-000
(Failed IDE CD-ROM test)
1. CD-ROM Drive Cables
2. CD-ROM Drive
3. System Board
215-XXX-001
(Failed IDE test)
1. System Board


217-XXX-000
(Failed BIOS Fixed Disk test)

Note
If RAID is configured, the fixed disk number refers to the RAID logical array.
1. Fixed Disk 1
217-XXX-001
(Failed BIOS Fixed Disk test)

Note
If RAID is configured, the fixed disk number refers to the RAIDlogical array.
1. Fixed Disk 2
217-XXX-002
(Failed BIOS Fixed Disk test)

Note
If RAID is configured, the fixed disk number refers to the RAID logical array.
1. Fixed Disk 3
217-XXX-003
(Failed BIOS Fixed Disk test)

Note
If RAID is configured, the fixed disk number refers to the RAID logical array.
1. Fixed Disk 4
217-XXX-004
(Failed BIOS Fixed Disk test)

Note
If RAID is configured, the fixed disk number refers to the RAID logical array.
1. Fixed Disk 5
217-XXX-005
(Failed BIOS Fixed Disk test)

Note
If RAID is configured, the fixed disk number refers to the RAID logical array.
1. Fixed Disk 6


264-XXX-0NN
(NN = SCSI ID of failing Tape Drive)


1. Tape Cartridge, if user executed the Read/Write Tape Drive test (XXX = 256)
2. SCSI or Power Cable connected to tape drive with SCSI ID NN.
3. Tape Drive with SCSI ID NN.
4. System board or SCSI Controller. (Run SCSI Controller Diagnostic to determine if the SCSI bus is functioning properly.)
264-XXX-999
(Errors on muliple tape drives, see error text for
more info)
1. See error messages/text in the error log for detailed information on each individual tape drive error.
301-XXX-000
(Failed Keyboard test)
1. Keyboard
405-XXX-000
(Failed Ethernet test)
1. Verify that the ethernet disable jumper is not installed (see "System board jumpers").
2. System Board
405-XXX-00N
(Failed Ethernet test on adapter in PCI slot N)
1. Adapter in PCI slot N
2. System Board
415-XXX-000
(Failed Modem test)
1. Cable
2. Modem
3. System Board



Document Location

Worldwide

Operating System

Older System x:Operating system independent / None

[{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HWN04","label":"Older System x->Netfinity 5500"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
23 January 2019

UID