At a glance

The new IBM 0U and 1U Power Distribution Units (PDUs) are the ideal solutions when you need flexible, reliable, easy-to-deploy power distribution with branch circuit protection to minimize downtime. These rack-dense units distribute power to up to 24 outlets in a 0U configuration and 12 outlets in a 1U configuration.

Overview

The new IBM 0U and 1U Switched and Monitored Power Distribution Units allow for quick and simple deployment, protection, and management of your high-availability IBM System x and BladeCenter rack environment.

New Button-mount designs on 0U PDU's help simplify deployment by providing tool-less rear mounting in IBM 9360, 9361, and 9362 model rack cabinets, reducing installation time.

IBM 0U vertical rack strip PDUs share a common space-efficient, power-dense design across the line. IBM 0U/1U available solutions include twenty-four IEC-320-C13 single-phase and twelve IEC-320-C19/C13 3-phase receptacles with single-phase 30A and 32A offerings, and three-phase 30A, 32A, and 50A offerings.

The new IBM 0U and 1U PDUs can be used separately or in combination with other IBM System x and BladeCenter PDUs to provide from a few outlets up to a full rack, scaling as required or as business needs change to support even greater power densities.

IBM 0U and 1U PDUs are engineered to stringent specifications to efficiently and cost effectively deliver power to the most power-dense IBM System x and BladeCenter environments.

Key prerequisites

None.

Warranty

  • IBM 0U 12 and 24 C19/C13 Switched and Monitored PDU - Three years
  • IBM 1U 12 C19/C13 Switched and Monitored C19/C13 PDU - Three years
  • 5U Kit and 2.8m Power Cord - One year

Packaging

IBM 0U 12 C19/12 C13 Switched and Monitored 3 Phase PDU, IBM 0U 24 C13 Single Phase Switched and Monitored PDU, and IBM 1U C19/C13 Switched and Monitored 3 Phase PDU with 4.3 m L21-30P cord one box

Dimensions/Weight

0U PDU (LxWxH):
  • 0U 12 PDU 1985 mm (78.1 inch) x 195 mm (7.7 inch) x 210 mm (8.3 inch)
  • 0U 24 PDU 1945 mm (76.6 inch) x 195 mm (7.7 inch) x 210 mm (8.3 inch)
  • 1U PDU 565 mm (22.2 inch) x 495 mm (19.5 inch) x 200 mm (7.9 inch)

Approximate 0U and 1U PDU weight:

  • 0U 12 PDU = 15 kg (33.07 lb)
  • 0U 24 PDU = 10 kg (22.04 lb)
  • 1U PDU = 14 kg (30.86 lb)

Shipment group

  • Warranty and Support Information Manual
  • CD containing User's Guide

Physical specifications

IBM 0U 12 C19/12 C13 3 Phase PDU :

Height : 108 mm (4.3 inch)
Width : 55 mm (2.2 inch)
Length : 1840 mm (70.9 inch)
Approximate weight : 11 kg (24 lb)

IBM 0U 24 C13 Single Phase PDU:

Height : 85 mm (3.3 inch)
Width : 44 mm (1.73 inch)
Length : 1800 mm (72.4 inch)
Approximate weight : 6 kg (13 lb)

IBM 1U C19/C13 3 Phase PDU:

Height : 42 mm (1.7 inch)
Width : 447 mm (17.6 inch)
Length : 350 mm (13.8 inch)
Approximate weight : 9 kg (20 lb)

Operating Environment

  • Operating Temperature: 10 to 55 deg C (50 to 122 deg F) - 0U and 1U models
  • Operating Relative Humidity: 5 - 90% (non-condensing)
  • Operating Elevation: 0-10000 feet (0-3048 m)

Product marketing and replacement part numbers (FRU)

Description Marketing part number Replacement part number
IBM 1U 9 C19/3 C13 Switched and Monitored 30A 3 Phase PDU 46M4167 46M4169
IBM 0U 24 C13 Switched and Monitored 30A PDU
46M4116 46M4118
IBM 0U 12 C19/12 C13 Switched and Monitored 50A 3 Phase PDU 46M4134 46M4136

Hardware requirements

The new 0U 12/24 C19/C13 and 1U C19/C13 Switched and Monitored PDUs should be configured with IBM System x or BladeCenter servers.

Software requirements

None.

Compatibility

None.

Limitations

None.

Document Location

Worldwide

Operating System

System x Hardware Options:All operating systems listed

[{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QUOEABJ","label":"System x Hardware Options->Power Accessories->Power distribution unit (PDU)->46M4167"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"QUOEABK","label":"System x Hardware Options->Power Accessories->Power distribution unit (PDU)->46M4116"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"QUOEABL","label":"System x Hardware Options->Power Accessories->Power distribution unit (PDU)->46M4134"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
24 January 2019

UID

ibm1MIGR-5086793