Product Documentation
Abstract
Features and technical details of Tower UPS and country line cords overview for eServer xSeries Servers.
Content
At a glance
New, high availability uninterruptible power supply (UPS) options deliver cost-effective power protection, extended run time power backup, and smart power management to xSeries servers.
- Three unique volt ampere (VA) points; up to 1,500 Volt Amps (VA) and 1,050 watt load capacity
- Support for all IBM eServer xSeries stand alone towers
- USB and serial communications standard
- UPS management software that integrates with IBM Director for seamless systems management
- Hot-swap internal battery
- Six or eight outlets, depending on model
- Three-year, on-site, limited warranty (1)
Overview
Now you can protect and substantially extend the backup power run times of your mission critical applications with cost effective, high availability, uninterruptible power supply (UPS) options.
UPS750T,1000T,1500T LV, HV, AND JVUPS OPTIONS
- Suite of easy to use management software
- Stand alone tower installation
- USB and Serial management on all units
- Reliable power protection with advanced management features and software
- Better value, lower price, and more power at each volt ampere (VA) rating
- Back door protection for attached devices with higher VA units
- Substantial battery run times even under full load
- Three year on-site warranty (1)
These UPS options are more cost effective than predecessors and provide higher wattage levels each VA point. This means you can power more or higher power equipment with longer battery run times than previously available. In addition, they offer these high-availability features and functions:
- Ability to supply six or eight outlets
- USB and Serial communication ports are standard
- Surge protection for phone/fax/modem on the 1000 and 1500VA units
- APC PowerChute Business Edition for IBM management software
- Support for unattended shut down
- Open Smart Slot for adding more functionality to the UPS
- High efficiency with higher wattage at each VA point
Warranty
3 year, Customer Carry In/Exchange
Packaging
UPS750TLV, UPS1000TLV, and UPS1500TLV
One box
- Base UPS with USB, serial, and smart slot
- Fixed 6 foot power cord
- 2m Serial cable (RS232)
- 2m Nema 5-15P jumper cord
- 2m USB cable
-
1000T and 1500T units also include:
- One RJ-45 CAT5 Network cable (1.8m)
- One RJ-11 Phone line cable (1.8m)
- PowerChute Business Edition CD
- User manual and warranty information
UPS750THV, UPS1000THV, UPS1500THV
- Base UPS with USB, serial, and smart slot
- 2m Serial cable (RS232)
- 2m USB cable
-
1000T and 1500T units also include:
- One RJ-45 CAT5 Network cable (1.8m)
- One RJ-11 Phone line cable (1.8m)
- Rack jumper power cables (IEC 320 C13/C14), 3 in UPS750T, 4 in UPS1000T and UPS1500T
- PowerChute Business Edition CD
- User manual and warranty information
UPS750TJV, UPS1000TJV, and UPS1500TJV
- Base UPS with USB, serial, and smart slot
- Fixed 6 foot power cord
- 2 Serial cable (RS232)
- 2m Nema 5-15P jumper cord
- 2m USB cable
-
1000T and 1500T units also include:
- One RJ-45 CAT5 Network cable (1.8m)
- One RJ-11 Phone line cable (1.8m)
- PowerChute Business Edition CD
- User manual and warranty information
Product marketing and replacement part numbers (FRU)
North America, Latin America, Asia Pacific, Europe, Middle East, and Africa| Description | Machine Type model | Replacement part number (FRU) |
|---|---|---|
| IBM UPS750T LV with bezel and battery | 2130-1TX | 90P4884 replaces 90P4817 |
| IBM UPS1000T LV with bezel and battery | 2130-3TX | 90P4818 |
| IBM UPS1500T LV with bezel and battery | 2130-5TX | 90P4819 |
Latin America, Asia Pacific, Europe, Middle East, and Africa
| Description | Machine Type model | Replacement part number (FRU) |
|---|---|---|
| IBM UPS750T HV with bezel and battery | 2130-2TX | 90P4820 |
| IBM UPS1000T HV with bezel and battery | 2130-4TX | 90P4821 |
| IBM UPS1500T HV with bezel and battery | 2130-6TX | 90P4822 |
Japan
| Description | Machine Type model | Replacement part number (FRU) |
|---|---|---|
| IBM UPS750T JV with bezel and battery | 2130-7TX | 90P4886 replaces 90P4823 |
| IBM UPS1000T JV with bezel and battery | 2130-8TX | 90P4824 |
| IBM UPS1500T JV with bezel and battery | 2130-9TX | 90P4825 |
Technical specifications
Physical specifications
UPS750T, UPS1000T and UPS1500T models:
- Height: 215.9mm (8.5 inches)
- Width: 170.2mm (6.7 inches)
- Depth: 439.4mm (17.3 inches)
-
Weight:
- 19.5kg (43lbs) (750/1000 models)
- 25.0kg (55lbs) (1500 model)
Operating environment
- Temperature: 0 to 40 degrees Celsius (32 to 104 degrees Fahrenheit) at 0 to 3000m(0 to 10,000 foot)
- Relative humidity: 0% to 95%
- Maximum Altitude: 3,000m (10,000 foot)
Electrical specifications
UPS750TLV, UPS1000TLV, UPS1500TLV
- 82 to 147V AC
- 12A
- 50/60Hz
UPS750THV, UPS1000THV, UPS1500THV
- 220 to 240V AC single phase
- 7A
- 50/60Hz
Audible noise at 1 meter: <50 dBA (80% load)
Audible noise at 1 meter: <55 dBA (100% load)
Online thermal dissipation: 300 BTU/hr
Agency approvals
UPS750T,1000T,1500T LV, HV, AND JV
- FCC - Verified to comply with Part 15 of the FCC Rules for a Class A digital device
- UL 1778
- CSA C22.2 Number 950
- NOM
- CE Mark (EN55022 Class A)
- C-Tick Mark (AS/NZS 3548 Class A)
- VDE EN50091-1-1 and 60950
- GOST - Russia
- Type Approval - South Korea
- Taiwan (BCIQEMC Type Certification)
Hardware requirements
None
Software requirements
The UPS750T, UPS1000T, and UPS1500T provide backup power to your server regardless of what operating system is used.
However, to enjoy the benefits and manageability features provided with PowerChute Business Edition one of the following operating systems must be used:
- Windows 2003
- Windows NT 4.0 with Service Pack 6
- Windows 2000 (Professional, Server, and Advanced Server) with SP3
- Windows XP
- Red Hat Linux V7.3 and 8.0
- SuSE V7.2 and 7.3
- TurboLinux V7.0
- TurboLinux V7.0
- Novell NetWare 5.1 with Support Pack 3 or later
- Novell NetWare 6.0 with Support Pack 1
Compatibility
The PowerChute Business Edition software is compatible with IBM Director. The UPS750T, UPS1000T, and UPS1500T options are compatible with all eServer xSeries servers and IntelliStation workstations and other supporting devices that require AC power.
Limitations
None
Document Location
Worldwide
Was this topic helpful?
Document Information
Modified date:
24 January 2019
UID
ibm1MIGR-52934