IBM Support

Features and specifications - IBM eServer xSeries 330

Product Documentation


Abstract

The following provides a summary of the features and specifications for the eServer xSeries 330 server. Depending on the server model, some features and specifications might not apply. Microprocessor Intel Pentium III microprocessor with MMX tec

Content

The following provides a summary of the features and specifications for the eServer xSeries 330 server. Depending on the server model, some features and specifications might not apply.

Microprocessor
  • Intel Pentium III microprocessor with MMX technology and SIMD extensions
  • 256KB Level-2 cache
  • Supports up to two microprocessors
Memory
  • Standard: 256MB
  • Maximum: 4GB
  • Type: 133MHz, ECC, SDRAM, Registered DIMMs
  • Slots: 4 dual inline
Drives standard
  • Diskette: 1.44MB
  • CD-ROM: 24X IDE
Expansion bays
  • Two 3.5-inch slim high bays for LVD SCSI hard disk
PCI expansion slots
  • Two 33MHz/64-bit
Power supply
  • One 200W (115-230 Vac)
Video
  • S3 video controller (integrated on system board)
  • Compatible with SVGA
  • 8MB SDRAM video memory
Size
  • Height 43.69mm (1.72 inch)
  • Depth: 653.29mm (25.72 inch)
  • Width: 439.93mm (17.32 inch)
  • Weight: approximately 12.7kg (28lb) when fully configured
Integrated functions
  • Advanced System Management processor
  • One Ultra160 SCSI controller
  • Two 10BASE-T/100BASE-TX Intel Ethernet controllers
  • Two Universal Serial Bus (USB) ports
  • Two RS-485 Advanced System Management processor ports (one In, one Out)
  • One serial port
  • Two console ports (one In, one Out)
Acoustical noise emissions
  • Sound power, idling: 6.1 bel maximum
  • Sound power, operating: 6.2 bel maximum
Environment


Air temperature

  • Server on: 10? to 35? Celsius (50.0 to 95.0Fahrenheit). Altitude: 0 to 914m (2998.7 ft.)
  • Server on: 10? to 32? Celsius (50.0 to 89.6Fahrenheit). Altitude: 914m (2998.7 ft.) to 2133m (6998.0 ft.)
  • Server off: 10? to 43? Celsius (50.0 to 109.4Fahrenheit). Maximum altitude: 2133m (6998.0 ft.)

Humidity

  • Server on: 8% to 80%
  • Server off: 8% to 80%
Heat output

Approximate heat output in British Thermal Units (BTU) per hour

  • Minimum configuration: 273 BTU (80 watts)
  • Maximum configuration: 751 BTU (220 watts)
Electrical input
  • Sine-wave input (50-60Hz) required
  • Input voltage low range:
    • Minimum: 100V AC
    • Maximum: 127V AC

  • Input voltage high range:
    • Minimum: 200V AC
    • Maximum: 240V AC

  • Input kilovolt-amperes (kVA) approximately:
    • Minimum: 0.08 kVA
    • Maximum: 0.22 kVA

Document Location

Worldwide

Operating System

System x:All operating systems listed

[{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QUOED9J","label":"Older System x->xSeries 330->8654"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
24 January 2019

UID