Front view Netfinity EXP200 Storage Expansion Unit (35301RU)
- The Netfinity EXP200 (3530-1RU) is an ideal solution for enterprise, business-critical applications requiring high speed and large amounts of data storage, protected by fault-tolerant, high-availability features.
- A hot-plug power supply and cooling fans provide the resiliency to keep network server applications up-and-running.
Description
High-Capacity/High-Availability
- The Netfinity EXP200 is a cost-effective, large capacity, high-availability solution for enterprise customers using rack cabinets or for installations requiring free-standing tower configurations. With 10 hot-swap, half-high drive bays, each Netfinity EXP200 can support up to 364 GB of high-speed (up to 80 MB/sec) data storage when attached to a supported Wide Ultra2 SCSI adapter or integrated Netfinity controller. Because of its compact 3U design, up to 14 EXP200 units can be housed in a single 42 U rack cabinet, yielding disk storage of over 5 terabytes.
- The Netfinity EXP200 is resilient to failure. The optional hot-swap Netfinity EXP200 350 W Redundant Power Supply can be quickly swapped out if a failure occurs without powering down the server or the Netfinity EXP200. Each power supply contains its own power cord. Two hot-swap cooling units, containing separate dual fans, provide cooling redundancy. If a failure occurs with either of the redundant power supplies or cooling fans, an LED will light to indicate a fault and its location.
- The Netfinity EXP200 contains SCA-2 (direct-dock), hot-swap drive bays that support replacement of disk drives without powering down the server. This feature, in combination with supported Netfinity ServeRAID adapters, provides fault-tolerant data storage solutions. The best way to avoid a problem is to detect it before it occurs. All Netfinity EXP200 HDD options contain the PFA feature that, when used in conjunction with Netfinity Manager, can alert the system administrator of an impending disk drive failure up to 24 hours before it occurs. The failing unit can be replaced before it degrades server performance.
- The Netfinity EXP200 contains an electronics board that interfaces between the external SCSI cables and hot-swap backplane. This board splits the backplane into two SCSI buses to support duplexing solutions. Twin-tailing is used with clustering software and allows two servers to be attached to a single Netfinity EXP200 for mission-critical enterprise storage solutions. The Netfinity EXP200 can support two servers sharing the same SCSI channel or two servers configured to use both SCSI buses independently. Clustering provides a very high degree of fault tolerance and high availability, because the network can continue to operate even if one of the servers goes offline. The remaining server can then take over, using the common data storage of the EXP200. Refer to the Planning Information section of the product announcement for more information on configuring the Netfinity EXP200.
Technical information
- Physical specifications
Approximate width: 447 mm (17.6 in)
Approximate depth: 571.5 mm (22.5 in)
Approximate weight: 36.1 kg (79 lb) (fully configured)
Rail Weight: 3.4 kg (7.5 lb)
- Operating environment temperature:
10 to 32 degrees C (50 to 90 degrees F) at 914 to 2,133 m (3,000 to 7000 ft.)
- Relative humidity: 8% to 80%
- Maximum altitude: 2,133 m (7,000 ft.)
- Agency approvals
- FCC -- Verified to comply with Part 15 of the FCC Rules for a Class A digital device
- CE Mark (EN55022 Class A)
- C-Tick Mark (AS/NZS 3548 Class A)
- Canada (ICES/NMB)
- VCCI Class A
- UL
- CSA
- TUV/GS
- NOM
- Taiwan (BCIQEMC Type Certification)
- Russia GOST-R
- ENERGY STAR-compliant: No
- Rack requirements:
- 19-inch EIA-310-D industry standard rack height is 3U (1U = 1.75 in)
- Width 133.35 mm (5.25 in)
- Depth 609.6 mm (24 in) minimum 787.4 mm (31 in) maximum
Slim line or half height drive options.
- The Netfinity EXP200 shares the same drive options as the new Netfinity 8500R platform. This helps customers reduce service and support costs associated with maintaining replacement drive options.
- Supported drive options are pre-mounted on a common, hot-swap drive carrier:
- Hot swap drive carriers are only available as part of the optional hot swap HDD assembly.
- NOTE: Do not remove the drive from hot-swap drive carrier: Removal of the drive from hot-swap drive carrier voids the warranty.
- Included drive bezels are in slimline and half height.
- All bays must be occupied by a drive or a blank bezel to provide proper air flow for cooling.
- Do not discard the blank bezels.

The rear panel
- 2 external connections VHDCI 0.8 mm (female) LVD SCSI or SE SCSI
- SCSI ID and option switches
- The optional hot-swap Netfinity EXP200 350 W Redundant Power Supply can be quickly swapped out if a failure occurs without powering down the server or the Netfinity EXP200.
- Each power supply contains its own power cord.
- Two hot-swap cooling units, containing separate dual fans, provide cooling redundancy.
- If a failure occurs with either of the redundant power supplies or cooling fans, an LED will light to indicate a fault and its location.
Shipment Group
- Netfinity EXP200
- 2 M Ultra2 SCSI Cable
- Rack mounting kit
- U.S. power cord (1)
- Installation publications and warranty information
Key Prerequisites
- Hard Disk Drives
- Server with SCSI adapter
- SCSI cable
Hardware Requirements:
- The Netfinity EXP200 is supported in configurations where it is connected to an external SCSI connector of various supported SCSI adapters or controllers of Netfinity servers.
- The Netfinity EXP200 requires a dedicated SCSI channel. It is not supported in configurations that split the SCSI bus for internal and external devices.
- The Netfinity EXP200 is supported with the following adapters:
| Description | Part number |
|---|---|
| ServeRAID (TM) II Ultra SCSI Adapter | 76H3584 (1) |
| Netfinity ServeRAID-3H Ultra2 SCSI Adapter | 01K7207 (1) |
| Netfinity ServeRAID-3HB Ultra2 SCSI Adapter | 37L6086 (1) |
| Netfinity ServeRAID-3L Ultra2 SCSI Adapter | 01K7364 (1) |
| Netfinity Fibre Channel RAID Controller Unit* | 35261RU (1) |
| Netfinity Fibre Channel Failsafe RAID Controller (3) | 01K7296 (1) |
| IBM PCI Fast/Wide Ultra SCSI Adapter | 02K3454 (2) |
See Servers - SCSI connector photos, specifications, and Netfinity SCSI options
Notes:
1. Requires one of the following external cables:
- 2 M Ultra2 SCSI Cable (03K9310) Standard with the Netfinity EXP200
- 4.2 M Ultra2 SCSI Cable (03K9311)
- 20 M Ultra2 SCSI Cable (37L7101 )
2. Requires one of the following external cables:
- 2 M External .8mm SCSI Cable (01K8027)
- 4.3 M External .8mm SCSI Cable (01K8029)
3. Support for Fibre Channel is planned with a firmware update available during the fourth quarter of 1999 .
- For the latest information about adapters supported in your Netfinity server, visit our Web site at: http://www.ibm.com/servers/eserver/serverproven/compat/us/
- Netfinity EXP200 is supported in the these Netfinity servers, using the external SCSI connector of the integrated Wide Ultra SCSI RAID controller. These are the only Netfinity servers that support the Netfinity EXP200 attached directly to an integrated SCSI controller.
| Machine Description | Type | Model |
|---|---|---|
| Netfinity 5500 | 8660 | All(1) |
| Netfinity 5500 M10 | 8661 | All |
| Netfinity 5500 M20 | 8662 | All |
| (1) Requires the Netfinity SCSI Controller Cable (03K9313 * ) to provide the external connection port. |
- The Netfinity EXP200 supports the following devices for internal installation:
| Part Number | Description | Announcement |
|---|---|---|
| 36L9744 | Netfinity 9.1 GB Wide Ultra2 SCSI Hot-Swap SL HDD | 199-248 |
| 36L9745 | Netfinity 18.2 GB Wide Ultra2 SCSI Hot-Swap SL HDD | 199-248 |
| 36L9746 | Netfinity 36.4 GB Wide Ultra2 SCSI Hot-Swap HDD | 199-248 |
| 36L9748 | Netfinity 9.1 GB 10K-3 Wide Ultra2 SCSI Hot-Swap SL HDD | 199-248 |
| 36L9749 | Netfinity 18.2 GB 10K-3 Wide Ultra2 SCSI Hot-Swap SL HDD | 199-248 |
| 36L9750 | Netfinity 36.4 GB 10K-3 Wide Ultra2 SCSI Hot-Swap HDD | 199-248 |
- Netfinity EXP200 supports these Wide Ultra2 HDDs listed in Announcement 199-257 . It does not support Wide Ultra HDDs.
- Hot-swapping of HDDs is restricted to an HDD that is inactive or where a lighted fault LED is indicated.
- Netfinity EXP200 is not supported when the SCSI channel of the SCSI adapter to which it is attached is split between internal devices and external devices.
- Each Netfinity EXP200 must be attached to a dedicated SCSI channel of a supported SCSI adapter.
- The standard Netfinity EXP200 configuration is supported as a rack drawer and is not currently supported for stacking directly on one another.
- Netfinity EXP200 can be installed in Netfinity NetBAY3 storage units stacked up to three units high, with a supported server on top.
- The Netfinity EXP200 shares the same drive options as the new Netfinity 8500R platforms.
Additional Options
| Description | Part number |
|---|---|
| EXP200 Rack-to-Tower Kit | 37L5857 |
| EXP200 Redundant Power Supply | 37L0075 |
| 20 M Ultra2 SCSI Cable | 37L7101 |
| Netfinity EXP200 HMM order number S10L-9839 | 09N1393 IBM PUB (800)879-2755 |
Product Positioning
- The Netfinity EXP200 is positioned above the Netfinity EXP15 due to its higher performance capability.
- The Netfinity EXP200 is scheduled to replace the Netfinity EXP15.
- See Announcement 199-257
Servers - SCSI connector photos, specifications, and Netfinity SCSI options
Document Location
Worldwide
[{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QU92GZW","label":"Older System x->Netfinity 8500R->8681->4RY"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"QU92GZY","label":"Older System x->Netfinity 8500R->8681->5RY"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"QU92HAC","label":"Older System x->Netfinity 8500R->8681->6RY"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"QU92HAE","label":"Older System x->Netfinity 8500R->8681->4RG"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"QU92HAG","label":"Older System x->Netfinity 8500R->8681->5RG"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"QU92HAI","label":"Older System x->Netfinity 8500R->8681->6RG"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}}]
Was this topic helpful?
Document Information
Modified date:
24 January 2019
UID
ibm1MIGR-4CPSC7