Processors- Intel Pentium III Xeon processor with Streaming SIMD Extensions
- Expandable to eight 550MHz Pentium III Xeon processors
- 100MHz Front Side Bus (FSB)
- 16KB of level 1 cache memory
- 512KB, 1MB, or 2MB of level 2 cache with error checking and correction (ECC) Memory integrated into processor
- Upgradable processor speeds when available
Memory
- One memory board standard
- Sixteen 168-pin, dual inline memory-module (DIMM) connectors
- Supports up to 8GB
- Expandable to 16GB
- 100MHz, PC100, registered synchronous dynamic random-access memory (SDRAM) with ECC
- Support for 128MB, 256MB, and 512MB DIMMs
- Support for a second memory board (optional)
Disk drives
- Supports one diskette drive
- Standard: One 3.5 inch, 1.44MB
Hard disk drives
- Two half-high, 3.5 inch drive bays
- Supports up to two internal hard disk drives
CD-ROM drive
- Standard: Integrated drive electronics (IDE)
Expansion slot connectors
- 12 available PCI slot connectors
- Eight 64-bit, 33MHz, hot-plug PCI slot connectors
- Four 64-bit, 66MHz, hot-plug PCI slot connectors
- Standard: I/O integrated function card
- Standard: Advanced System Management PCI adapter
Upgradable features
- Advanced System Management PCI adapter upgrades (when available)
- Diagnostics upgrades (when available)
- POST/BIOS upgrades (when available) to update electrically erasable programmable read-only memory (EEPROM) on the I/O integrated function card
Security features
- Chassis-intrusion detector (tower option only)
- Power-on and administrator passwords
- Security-error indicator (tower option only)
- Selectable drive-startup sequence
- Cover lock (tower option only)
- Unattended start mode
SCSI features
- Wide Ultra-2 SCSI (LVD) controller 1
- One external connector
- One internal connector
- Two bays available for internal SCSI hard disk drives
Power supplies
- Three - 750W power supplies standard
- Redundant power available
- Hot-swap capable
- Auto-sensing function
- Built-in overload and surge protection
- Automatic restart after a loss of power
Predictive Failure Analysis (PFA) alerts
- Fans
- Power supplies
- Memory
- Hard disk drives
- Processors
Integrated functions
- Voltage regulators for processors
- Two serial ports
- Two Universal Serial Bus (USB) ports
- One parallel port
- Mouse port
- Keyboard port
- Video port
- Wake on LAN capability
- Alert on LAN capability
- Advanced System Management PCI adapter
- Full-duplex 10/100Mbps Ethernet controller for system management use
- Advanced System Management Interconnect port
- Two serial ports
- ServeRAID adapter support
- Built-in programmable read-only memory (PROM) based diagnostics
Size
- Depth: 747mm (29.4 inch)
- Height: 356mm (14 inch) (8 U)
- Width: 440mm (17.3 inch)
Weight
- Unpacked, minimum configuration: 67kg (147 lb.)
- Unpacked, maximum configuration: 77.5kg (170 lb.)
Electrical input
- Sine-wave input (50 or 60Hz) is required
- Input voltage
- Low range
- Minimum: 90V AC
- Maximum: 137V AC
- High range
- Minimum: 180V AC
- Maximum: 265V AC
- Input kilovolt-amperes (KVA) approximately
- Minimum configuration as shipped: 0.5 KVA
- Maximum configuration: 2.1 KVA
Environment
Air temperature
- System on: 10° to 35° Celsius (50° to 95° Fahrenheit)
- Altitude: 0 to 914m (3000 ft.)
- System on: 10° to 32° Celsius (50° to 89.6° Fahrenheit)
- Altitude: 0 to 2133m (7000 ft.)
- System off: 10° to 43° Celsius (50° to 110° Fahrenheit)
Humidity
- System on: 8% to 80%; maximum wet-bulb 23° C (73.4° F)
- System off: 8% to 80%; maximum wet-bulb 27° C (80.6° F)
Electrostatic discharge
- Tested to 20KV
Immunity
- Verified to comply with EN 50082-2
Acoustical noise emission values
Declared (upper limit) sound power levels
- Netfinity 8500R server (rack server)
- 6.1 bels operating
- 6.1 bels idle
- Netfinity 8500R server (tower option)
- 6.2 bels operating
- 6.2 bels idle
Mean value of the A-weighted sound pressure levels at the bystander (1 meter) position
- Netfinity 8500R server (rack server)
- 45.0 dB operating
- 45.0 dB idle
- Netfinity 8500R server (tower option)
- 43.5 dB operating
- 43.0 dB idle
Heat output
Approximate heat output in British thermal units (Btu) per hour:
- Minimum configuration: 1700 Btu/hr.
- Maximum configuration: 7000 Btu/hr.
Safety standards
- UL 1950, Third Edition
- CSA C22.2 No. 950-95
- EN 60950 and countries deviations
- IEC 950
- NOM-019
NOTES:
- These levels are measured in controlled acoustical environments according to ISO 7779, and are reported in accordance with ISO 9296.
- The declared sound power levels indicate an upper limit, below which a large portion of machines operate.
- These values apply to a random sample of machines.
- There is no impulsive noise, and there are no prominent tones.
- For additional information on the Netfinity 8500R server (tower option), refer to IBM Netfinity rack to tower conversion kit Installation Instructions.
Document Location
Worldwide
[{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW18W","label":"Older System x->xSeries 370"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HWN07","label":"Older System x->Netfinity 8500R"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}}]