IBM Support

Announcement Letter - 3519 Rack Storage Expansion Enclosure

Product Documentation


Abstract

The Personal Computer Company releases the IBM PC Server 3519 Rack Storage Expansion Enclosure and Related Options.

Content

The Personal Computer Company releases the IBM PC Server 3519 Rack Storage Expansion Enclosure and Related Options for announcement by:

IBM United States - Market Operations
IBM Personal Computer Company - Americas
IBM Asia Pacific - North
IBM Asia Pacific - South
IBM Latin America
IBM Canada, Ltd.
IBM Europe/Middle East/Africa Corporation

The IBM PC Server 3519 Rack Storage Expansion Enclosure is a perfect solution to address your needs for affordable, high-availability data storage, designed for industry standard rack cabinets. The PC Server 3519 contains six hot-swap drive bays allowing installation of various hard disk drive options for hot-swap data storage of up to 27GB(1). It also features a 200W world-wide power supply, three 5.25-inch half-high drive bays to support additional SCSI devices, two cooling fans, a PC Server SCSI-2 F/W Enhanced Repeater to ensure signal quality for SCSI disk drives, and a mounting slot to support an optional SCSI repeater card.

The PC Server 3519 Rack Storage Expansion Enclosure features these high-availability attributes:

o Hot-swap hard disk drive bays to support RAID solutions
o Redundant cooling fans with visual and audio alerts
o Twin-tail capability for clustering applications

The 3519 supports both PC Server 4.51GB and 9.1GB Wide Ultra SCSI Hot-Swap Hard Disk Drives and can be attached to an IBM PC Server that contains and supports either the PC ServeRAID SCSI Adapter or the PC Server Ultra Wide SCSI PCI Adapter options. The IBM SCSI Storage Extender Cable allows for two PC Server 3519 Rack Storage Expansion Enclosures to be daisy-chained from a supported adapter or controller for additional storage capacity.

(1) When referring to hard drive capacity, GB stands for one thousand million bytes. Total user-accessible capacity may vary depending on operating environments.

(2) Limited warranty includes Warranty Service in those countries where this product is sold by IBM or IBM Business Partners
(registration required).

US, PCNA, CAN--->
(1) For information on IBM's Statement of Limited Warranty, please call 800-426-7378 or contact your IBM representative or reseller. Copies are available upon request.
<---US, PCNA, CAN

AP, LA, EMEA--->
(2) For information on IBM's Statement of Limited Warranty, contact your local IBM representative. Copies are available upon request.
<---AP, LA, EMEA

IBM, NetFinity, PartnerLink, OS/2, IBM Support Center, and HelpWare are trademarks or registered trademarks of International Business Machines Corporation.

TME 10 is a trademark of Tivoli Systems.

Other company, product, or service names, which may be denoted by a double asterisk (**), may be trademarks or service
marks of others.

AT A GLANCE

Features of the
PC Server 3519 Rack Storage Expansion Enclosure include:

o Industry standard rack-mountable
o Six hot-swap drive bays supports high-performance 4.51GB and 9.1GB Wide Ultra SCSI Hot-Swap Hard Disk Drive options
o Three 5.25-inch, half-high bays for tape backup and additional disk or removable media storage
o Redundant cooling fans
o Enhanced, high-availability SCSI-2 repeater card
o 200W switchable power supply
o SCSI twin-tail capability
o A three-year, on-site, limited warranty


PC Server SCSI-2 F/W Enhanced Repeater

The PC Server SCSI-2 F/W Enhanced Repeater ensures signal quality for SCSI-2 devices installed in external SCSI enclosures. It allows longer cable lengths so that practical configurations are possible. This enhanced repeater card provides high-availability function by allowing the use of two repeater cards to be installed on the single SCSI bus supported by two SCSI host adapters used in clustering configurations. This function can provide the hardware link for failover recovery in cluster configurations when clustering software becomes available.

PC Server Wide SCSI Terminator

The PC Server Wide SCSI Terminator is a 16-bit active terminator that provides termination to the internal SCSI bus in configurations not requiring a hard disk drive. This option is required for SCSI termination of PC Server 325 and 330 open-bay systems that do not have a primary hard disk drive installed within the server. It should be installed on the last drop of the 16-bit internal SCSI cable contained in these systems.

IBM SCSI Storage Extender Cable

The IBM SCSI Storage Extender Cable is a 16-bit, SCSI-2 external cable designed to daisy-chain two PC Server 3519 Rack Storage Expansion Enclosures from a single controller. Up to twelve 4.51GB Wide Ultra SCSI Hot-Swap Hard Disk Drives can be installed in two enclosures from either a PC ServeRAID SCSI Adapter or PC Server Ultra Wide SCSI PCI Adapter.
This cable is 6 meters in length with a 68-pin SCSI connector at each end and a third connector in the middle of the cable (3 meters from each end).

PLANNED AVAILABILITY DATES:

o May 20, 1997

- PC Server SCSI-2 F/W Enhanced Repeater

o May 23, 1997

- PC Server 3519 Rack Storage Expansion Enclosure

o July 31, 1997

- IBM SCSI Storage Extender Cable
- PC Server Wide SCSI Terminator

PRODUCT NUMBERS

US, PCNA, AP, LA, CAN--->

Description                     Machine    Model     Part Number    

PC Server 3519 Rack 
Storage Expansion Enclosure     3519       R01       3519R01       
                                                                          
IBM SCSI Storage Extender Cable                      94G7594       
                                                                          
PC Server SCSI-2 F/W Enhanced Repeater               94G7585       
                                                                          
PC Server Wide SCSI Terminator                       94G7587      


<---US, PCNA, AP, LA, CAN


EMEA--->

Description                     Machine    Model     Part Number   

PC Server 3519 Rack 
Storage Expansion Enclosure     3519       R01        SR01xxx     


Note: Part numbers ending in "xxx" refer to country power cord Middle East/Africa countries, refer to Announcement Letter
ZG97-0272

IBM SCSI Storage Extender Cable                       94G7594      

PC Server SCSI-2 F/W Enhanced Repeater                94G7585      

PC Server Wide SCSI Terminator                        94G7587      

<---EMEA


OFFICIAL PUBLISHED SPECIFICATIONS - TECHNICAL INFORMATION

IBM PC Server 3519 Rack Storage Expansion Enclosure

ENERGY STAR-COMPLIANT: No
Note: The Energy Star emblem does not represent EPA endorsement of any product or service.

PERFORMANCE SPECIFICATIONS: None

PHYSICAL SPECIFICATIONS:
o Approximate height: 216 mm (8.5 in)
o Approximate width: 482 mm (19.0 in)
o Approximate depth: 465 mm (18.3 in)
o Approximate weight: 14.3 kg (31.5 lb)

OPERATING ENVIRONMENT:
o Temperature: 10 to 35 degrees C (50 to 95 degrees F) at 0 to 914 m (0 to 3,000 ft.)
10 to 32 degrees C (50 to 90 degrees F) at 914 to 2,133 m (3,000 to 7000 ft.)
o Relative humidity: 8 to 80 percent
o Maximum Altitude: 2,133 m (7,000 ft.)

AGENCY APPROVALS:
o UL
o ULC
o TUV/GS
o IEC/CB
o SEMKO
o NOM

HARDWARE REQUIREMENTS:
The PC Server 3519 Rack Storage Expansion Enclosure is supported in configurations where the PC Server 3519 is connected to an external SCSI connector of a PC ServeRAID SCSI Adapter or PC Server Ultra Wide SCSI PCI Adapter installed and supported in one of the following PC Servers. The PC Server 3519 Rack Storage Expansion Enclosure requires a dedicated SCSI channel with either of these SCSI adapters. PC Server 3519 Rack Storage Expansion Enclosure is not supported in configurations that split the SCSI bus.


Description Machine Type Model
PC Server 310 8639 All (1)
PC Server 315 8638 All (2)
PC Server 320 8640 All (2)
PC Server 325 8639 All (2)
PC Server 330 8640 All (2)
PC Server 520 8641 All (2)
PC Server 720 8642 All (2)
PC Server 704 8650 All (2)


(1) Only supported when attached to a dedicated PC Server Ultra Wide SCSI PCI Adapter.
(2) Only supported when attached to either a PC ServeRAID SCSI Adapter or a dedicated PC Server Ultra Wide SCSI PCI Adapter.

Rack Requirements:
Height is 5u (1u = 1.75 in) 222.25 mm (8.75 in)
Depth 711.2 mm (28 in)
Rack rail to front door 75.4 mm (3 in) clearance

SOFTWARE REQUIREMENTS:
The PC Server 3519 is compatible with the network operating systems supported by the PC Server and supported SCSI controllers to which it is attached.

COMPATIBILITY:
The PC Server 3519 Rack Storage Expansion Enclosure supports the following devices for internal installation:

Description                                Part Number 
 
PC Server 2.25GB Fast/Wide SCSI-2 
Hot-Swap Hard Disk Drive III               70G9862 
                                                               
PC Server 4.51GB Wide Ultra SCSI 
Hot-Swap Hard Disk Drive                   94G7491
                                                                   
PC Server 9.1GB Wide Ultra SCSI 
Hot-Swap  Hard Disk Drive                  94G7492
                                                                 
PC Server 4.51GB W/W SCSI-2 SL 
Hot-Swap Hard Disk Drive III               94G6494
                                                               
PC Server SCSI-2 F/W Hot-Swap Drive Tray   70G9860 
IBM 4/10GB 4mm 5.25" DAT Tape Drive        74G8631
IBM Internal 8X CD-ROM                     76H3215
PC Server SCSI-2 F/W Enhanced Repeater     94G7585


The PC Server 3519 Rack Storage Expansion Enclosure is supported with the following adapters and cables:

Description                                 Part Number 

PC Server 3.0M SCSI-2 F/W Cable             94G5567 
PC Server 4.3M SCSI-2 F/W Rack Cable        94G5566
PC ServeRAID SCSI Adapter                   70G8489
PC Server Ultra Wide SCSI PCI Adapter       76H5407
IBM SCSI Storage Extender Cable             94G7594
IBM Expansion Enclosure Backplane Cable     70G9876


LIMITATIONS:
o No more than two 5.25-inch or 3.5-inch, half-high hard disk drives can be installed in the three 5.25-inch non-hot-swap drive bays of the PC Server 3519 Rack Storage Expansion Enclosure. These drives must be installed in the bays adjacent to the middle bay. To ensure adequate air flow, the middle half-high bay cannot be populated with a device.

o Wide Ultra SCSI drives can be installed in the PC Server 3519 Rack Storage Expansion Enclosure; however, Ultra SCSI mode is not supported. Wide Ultra SCSI drives installed in the PC Server 3519 Rack Storage Expansion Enclosure must be operated in a SCSI-2 Fast/Wide mode.

PLANNING INFORMATION

CABLE ORDERS REQUIRED: Yes
One of the following external cables must be ordered to attach the PC Server 3519 Rack Storage Expansion Enclosure to a supported SCSI connector:

o IBM SCSI Storage Extender Cable (94G7594)
o PC Server 3.0 SCSI-2 F/W Cable (94G5567)
o PC Server 4.3 SCSI-2 F/W Rack Cable (94G5566)

The following internal cable must be ordered to connect to a second PC Server SCSI-2 F/W Enhanced Repeater to support twin-tail configurations:
o IBM Expansion Enclosure Backplane Cable (70G9876)

INSTALLATION TIME: Approximately one hour

PACKAGING: One box
Shipment Group:
o PC Server 3519 with a SCSI repeater card
o Cable management arm
o Power cord
o Installation publications and warranty information

PUBLICATIONS
Publication             Order          Part 
Description             Number         Number 
PC Server 3519 HMM      S84H-7202      84H7202


SECURITY, AUDITABILITY, AND CONTROL
o PC Server 3519 Rack Storage Expansion Enclosure contains a lockable front door designed to prevent unauthorized personnel access to removable media devices and hot-swap disk drives.

Small Computer System Interface (SCSI), as defined in the American National Institute (ANSI) standard X3.131-1986, provides a port for attachment of external devices. The SCSI bus may be internal or external to the system unit. PC Servers using a PC ServeRAID SCSI Adapter or PC Server Ultra Wide SCSI PCI Adapter attached to the PC Server 3519 Rack Storage Expansion Enclosure are in conformance with this standard by having external ports on both the server and the expansion enclosure.

It is a customer's responsibility to ensure that the server and PC Server 3519 are secure to prevent sensitive data from being removed via the external SCSI ports. The PC Server can be secured through PC Server Security Cover options, while security of the PC Server 3519 must be maintained through the selection of a rack cabinet with appropriate security features.

PCNA, LA--->

FIELD REPLACEABLE UNITS (FRUs):

                         Part     Feature
Description              Number   Number   H  S   E
Hot-swap Backplane       06H8576  none     R  1
200W Power Supply        60H8301  none     R  2
Fan Assembly             60H9308  none     S  1 
Mechanical Asm.          60H9283  none     R  0   X         
Access Cover w Bezel     72H2643  none     S  0
SCSI Enh.Repeater        93H6409  2351     R  1
Front Door               60H8308  none     S  0  
Front Bezel              60H8300  none     S  0  
3-5.25" Blank Bezels     76H3451  none     S  0
Keylock w/keys           33F8433  none     S  0 
Internal SCSI Cable      60H8304  none     S  0 
LED/ON/Off Sw Cable      60H8302  none     S  0 
Misc Parts Kit           55H8179  none     S  1
Push Catch & Bracket     60H9285  none     S  0 
Hotswap Door Assy.       60H9284  none     S  0


Note:
'H' Warranty Handling - 'R' for Return or 'S' for Scrap
'S' Recommended Stock - An entry in this column indicates the recommended stocking quantity to support 1000 units
'E' Exchange Only - Replacement part is sold only with exchange of the defective part

<---PCNA, LA

IBM PC Server SCSI-2 F/W Enhanced Repeater

ENERGY STAR-COMPLIANT: No
Note: The Energy Star emblem does not represent EPA endorsement of any product or service.

PERFORMANCE SPECIFICATIONS:
The PC Server SCSI-2 F/W Enhanced Repeater supports SCSI-2 Fast/Wide operation (20MB/s).

PHYSICAL SPECIFICATIONS:
o Approximate height: 107 mm (4.2 in)
o Approximate width: 175 mm (6.9 in)

OPERATING ENVIRONMENT:
o Temperature: 10 to 35 degrees C (50 to 95 degrees F) at 0 to 914 m (0 to 3,000 ft.)
10 to 32 degrees C (50 to 90 degrees F) at 914 to
2,133 m (3,000 to 7,000 ft.)
o Relative humidity: 8 to 80 percent

AGENCY APPROVALS:
o Verified to comply with Part 15 of the FCC Rules for a Class A digital device
o CE Mark (EN 55022 Class A)
o CISPER 22, Class A
o IEC

HARDWARE REQUIREMENTS:
The PC Server SCSI-2 F/W Enhanced Repeater is supported in PC Server Enterprise Expansion Tower and PC Server 3519 Rack Storage Expansion Enclosure.

Description                  Machine Type     Model     Part Number
PC Server Enterprise         3518             001        3518001
Expansion Enclosure 
PC Server 3519 Rack Storage  3519             R01        3519R01
Expansion Enclosure


SOFTWARE REQUIREMENTS: No unique software is required for either PC Server SCSI-2 F/W Enhanced Repeater.

COMPATIBILITY: When installed in the PC Server Enterprise Expansion Tower and PC Server 3519 Rack Storage Expansion Enclosure, the PC Server SCSI-2 F/W Enhanced Repeater is compatible with all options supported by these enclosures. The PC Server SCSI-2 F/W Enhanced Repeater is compatible with the following SCSI adapters:

Description                           Part Number     Notes 
IBM SCSI-2 Fast/Wide Adapter/A        70G8498         1,2,3 
IBM SCSI-2 Fast/Wide Streaming        70G9263         1,2,3 
RAID Adapter/A 
PC Server SCSI-2 Fast/Wide PCI        94G3771         2,3,4 
Adapter  
PC Server SCSI-2 Fast/Wide PCI-Bus    94G2764         2,3,4 
RAID Adapter  
PC Server SCSI-2 Fast/Wide PCI        94G4673         2,3,4 
Adapter II 
PC Server Ultra Wide SCSI PCI         76H5407         2,3,4 
Adapter
PC Server 704 SCSI-2 F/W PCI          94G5884           5
RAID Adapter 
PC ServeRAID SCSI Adapter             70G8489          2,3,4

NOTE: All configurations may not be compatible. The adapters listed above require external SCSI cables to attach to the
PC Server SCSI-2 F/W Enhanced Repeater. The cables are identified below:

Description                            Part Number 
(1) SCSI-2 Card to SCSI-2 Option       06H3231
    Cable (1-meter)
(2) PC Server 3.0M SCSI-2 F/W          94G5567
    Cable *
(3) PC Server 4.3M SCSI-2 F/W          94G5566
    Rack Cable *  
(4) PC Server F/W to F/w External      70G9857
    SCSI Cable
(5) PC Server 8mm to 68-Pin            94G6276
    HD SCSI Cable


(*) When installing either of these cables on either SCSI adapters (70G8498) or (70G9263), a 68-pin SCSI-2 F/W converter (94G5569) is required between the cable and the external connector on the SCSI adapter.

LIMITATIONS:
The PC Server SCSI-2 F/W Enhanced Repeater limitations include:
o This adapter supports SCSI-2 Fast/Wide mode. Ultra SCSI mode is not supported.

o A maximum of 12 Fast/Wide SCSI-2 hot-swap disk drives are supported on a single SCSI channel when attached to a PC ServeRAID SCSI Adapter or PC Server Ultra Wide SCSI PCI Adapter. A maximum of seven SCSI devices are supported on a single channel when attached to all other supported SCSI adapters.

o Daisy-chaining of backplanes within a PC Server Enterprise Expansion Tower is supported when attached to either the PC ServeRAID SCSI Adapter or PC Server Ultra Wide SCSI PCI Adapter configured as follows:

- Up to two backplanes when using slim-high, hot-swap hard disk drives
- Up to three backplanes when using half-high, hot-swap hard disk drives

o Daisy-chaining is supported on other SCSI adapters in the following configuration:

- Up to two backplanes when using half-high, hot-swap hard disk drives

PLANNING INFORMATION

CABLE ORDERS REQUIRED: Yes.
Refer to the COMPATIBILITY section for cables required to attach PC Server SCSI-2 F/W Enhanced Repeater to various SCSI adapters.

The PC Server Enterprise Expansion Tower connects to one or more external SCSI-2 Fast/Wide connectors on the host system through an external cable that goes to the back of the enclosure. An internal cable brings the signal from the back of the enclosure to the backplane or media bays. When a PC Server SCSI-2 F/W Enhanced Repeater is installed in the PC Server Enterprise Expansion Tower, the external cable will instead attach to the external connector of the PC Server SCSI-2 F/W Enhanced Repeater and the internal cable will attach to the internal connector on the PC Server SCSI-2 F/W Enhanced Repeater. Any additional cabling configurations to support internal expansion of the PC Server Enterprise Expansion Tower remain unchanged from the PC Server Enterprise Expansion Tower announcement.

INSTALLATION TIME: Approximately 15 minutes

PACKAGING: One box

Shipment Group:
SCSI-2 Repeater Card
Installation Instructions

PUBLICATIONS: None

SECURITY, AUDITABILITY, AND CONTROL

This product uses the security and auditability features of the PC Server enclosures in which it is installed.

Small Computer System Interface (SCSI), as defined in the American National Institute (ANSI) standard X3.131-1986, provides a port for attachment of external devices. The SCSI bus may be internal or external to the system unit. PC Servers using a PC Server SCSI-2 F/W Enhanced Repeater, PC Server 3519 Rack Storage Expansion Enclosure, and the PC Server Enterprise Expansion Tower are in conformance with this standard by having external ports on both the server and the expansion enclosure.

It is a customer's responsibility to ensure that the server products are secure to prevent sensitive data from being removed via the external SCSI ports.

PCNA, LA--->

FIELD REPLACEABLE UNITS (FRUs):

                 Part     Feature
Description      Number   Number    H  S

Repeater Card    93H6409   2351     R  1
Card bracket kit 75H9840   2351     S  0

Note:
'H' Warranty Handling - 'R' for Return or 'S' for Scrap
'S' Recommended Stock - An entry in this column indicates the recommended stocking quantity to support 1000 units
'E' Exchange Only - Replacement part is sold only with exchange of the defective part

<---PCNA, LA

IBM PC Server Wide SCSI Terminator

ENERGY STAR-COMPLIANT: No
Note: The Energy Star emblem does not represent EPA endorsement of any product or service.

PERFORMANCE SPECIFICATIONS: None

PHYSICAL SPECIFICATIONS:
o 68-pin active SCSI terminator

OPERATING ENVIRONMENT: None

AGENCY APPROVALS: None

HARDWARE REQUIREMENTS:
The PC Server Wide SCSI Terminator is supported on open-bay PC Server 325 and 330 non-hot-swap bay models.

Description        Machine Type     Model     Part Number
PC Server 325       8639             EJ0       8639EJ0
                    8639             ES0       8639ES0 
                    8639             RS0       8639RS0    
PC Server 330       8640             ES0       8640ES0


SOFTWARE REQUIREMENTS: No unique software is required.

COMPATIBILITY: None

LIMITATIONS: None

PLANNING INFORMATION: None

INSTALLATION TIME: Approximately 15 minutes

PACKAGING: One box

Shipment Group:
Wide SCSI Terminator
Installation Instructions

PUBLICATIONS: None

SECURITY, AUDITABILITY, AND CONTROL

This product uses the security and auditability features of the PC Servers in which it is installed.

PCNA, LA--->

FIELD REPLACEABLE UNITS (FRUs):

                 Part     Feature
Description      Number   Number    H  S
Terminator       92F0322   none     R  1

Note:
'H' Warranty Handling - 'R' for Return or 'S' for Scrap
'S' Recommended Stock - An entry in this column indicates the recommended stocking quantity to support 1000 units
'E' Exchange Only - Replacement part is sold only with exchange of the defective part

<---PCNA, LA


IBM SCSI Storage Extender Cable

ENERGY STAR-COMPLIANT: No

Note: The Energy Star emblem does not represent EPA endorsement of any product or service.

PERFORMANCE SPECIFICATIONS: None

PHYSICAL SPECIFICATIONS:
o 16-bit external SCSI cable
o Six meters in length
o Three 68-pin connectors

OPERATING ENVIRONMENT: None

AGENCY APPROVALS: None

HARDWARE REQUIREMENTS:
The IBM SCSI Storage Extender Cable is supported on PC Server 3519 Rack Storage Expansion Enclosure when attached to either a PC Server Ultra Wide SCSI PCI Adapter or PC ServeRAID SCSI Adapter external connectors.

SOFTWARE REQUIREMENTS: No unique software is required.

COMPATIBILITY: None

LIMITATIONS: None

PLANNING INFORMATION: None

INSTALLATION TIME: Approximately 15 minutes

PACKAGING: One box

Shipment Group:
External SCSI Cable
Warranty

PUBLICATIONS: None

SECURITY, AUDITABILITY, AND CONTROL

This product uses the security and auditability features of the PC Servers in which it is installed.

PCNA, LA--->

FIELD REPLACEABLE UNITS (FRUs)

                   Part     Feature
Description        Number   Number   H  S
Extender Cable     12J5676  none     R  1
Note:
'H' Warranty Handling - 'R' for Return or 'S' for Scrap
'S' Recommended Stock - An entry in this column indicates the recommended stocking quantity to support 1000 units
'E' Exchange Only - Replacement part is sold only with exchange of the defective part

<---PCNA, LA

Keywords: 3519R01 94G7585 94G7587 94G7594

Document Location

Worldwide

Operating System

System x:All operating systems listed

[{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"QU00XUG","label":"System x->Rack\/Storage Enclosures->3519"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
24 January 2019

UID

ibm1DDSE-42XRKR