Product Documentation
Abstract
Specifications for the PC Server 325.
Content
Size:
With pedestal:
- Depth: 473 mm (18.6 in.) 569 mm (22.6 in.) with cable cover
- Height: 455 mm (17.9 in.)
- Width: 315 mm (12.4 in.)
Without pedestal:
- Depth: 473 mm (18.6 in.) 569 mm (22.6 in.) with cable cover
- Height: 425 mm (16.7 in.)
- Width: 195 mm (7.7 in.)
Drawer model:
- Depth: 465 mm (18.3 in.)
- Height: 216 mm (8.5 in.)
- Width: 482 mm (19.0 in.)
Weight:
Typical server as shipped: 17.0 kg (37.5 lb)
Environment:
Air temperature:
Server on: 10C to 35C (50F to 95 F)
Altitude: 0 to 914 m (3000 ft.)
Server on: 10C to 32C
(50F to 90 F)
Altitude: 914 m (3000 ft.) to 2133 m (7000 ft.)
Server off: 10C to 43C
(50F to 110F)
Maximum Altitude: 2133 m (7000 ft.)
Humidity:
Server on: 8% to 80%
Server off: 8% to 80%
Maximum altitude: 2133 m (7000 ft)
Electrical Input:
Sine-wave input (50 to 60 Hz) is required
Input voltage:
- Low range:
Minimum: 90 V ac
Maximum: 137 V ac
- High range:
Minimum: 180 V ac
Maximum: 265 V ac
- Input kilovolt-amperes (kVA) approximately:
Minimum configuration as shipped: 0.08 kVA
Maximum configuration: 0.52 kVA
Total Power Available for Drives:
Nominal Operating Current allowed:
- +5 V dc line: 5.3 A
- +12 V dc line: 5.0 A
Heat Output:
Approximate heat output in British Thermal Units (BTU) per hour:
- Minimum configuration: 350 BTU (102 watts)
- Maximum configuration: 860 BTU (251 watts)
Document Location
Worldwide
Was this topic helpful?
Document Information
Modified date:
24 January 2019
UID
ibm1DDSE-42TRWH