Product Documentation
Abstract
These technical specifications of the PC Server 310 include physical properties, environment, heat ouptput, and electrical input.
Content
Specifications
Size
- Depth: 448 mm (17.6 in.)
- Height: 160 mm (6.3 in.)
- Width: 420 mm (16.5 in.)
Weight
- Min. configuration: 12.7 kg (28.0 lb)
- Max. configuration: 14.1 kg (31.0 lb)1
Environment
Air temperature:
- System on: 10 C to 32 C (50F to 90 F)
- System off: 10C to 43 C (50F to 110 F)
Humidity:
- System on: 8% to 80%
- System off: 8% to 80%
- Maximum altitude: 2134 m (7000 ft)
Heat Output
Approximate heat output in BTUs per hour:
- Min. configuration: 120 BTU (35 watts)
- Max. configuration: 1060 BTU (310 watts)2
- Deep sleep: 15 BTU (4 watts)
Electrical Input
Sine-wave input (50 to 60 Hz) required.
Low range input voltage:
- Min.: 110 V ac
- Max.: 125 V ac
High range input voltage:
- Min.: 200 V ac
- Max.: 240 V ac
Input kVA (approximately):
- Min. configuration as shipped: 0.08 kVA
- Max. configuration: 0.52 kVA
Airflow
Approximately 0.56 cubic meters/minute (20 CFM)
Acoustical Noise Emission Values
Average sound pressure levels:
- At operator position:
- 43 dB operating
- 43 dB idle
At bystander position (1 meter):
- 40 dB operatinng
- 40 dB idle
Declared (upper limit) sound power levels:
- 5.0 bels operating
- 4.8 bels idle
1. Maximum configuration weight depends on options installed. Figures above are a system fully populated with options.
2. Maximum power and heat specifications are based on the 200-watt maximum capacity of the system power supply.
3. For additional information, see the ISO Supplier's Declaration available from IBM.
Document Location
Worldwide
Was this topic helpful?
Document Information
Modified date:
24 January 2019
UID